• Title/Summary/Keyword: Absorption test

Search Result 1,433, Processing Time 0.029 seconds

Application of poly(vinyl acetate) and poly(1,4-butylene adipate) hydrophobic surface coatings on cementitious mortar specimens

  • Sanal, Irem;Yalcin, Bestenur;Yalcin, Ibrahim Ertugrul;Arda, Lutfi
    • Advances in concrete construction
    • /
    • v.11 no.4
    • /
    • pp.323-333
    • /
    • 2021
  • The main objective of this study is to characterize and evaluate the hydrophobic performance of polymer-based water-repellent coatings on cementitious mortar surfaces. Different concentrations of poly(vinyl acetate) (PVAc) and poly(1,4-butylene adipate) (PBA) were prepared in the laboratory and their applicability and performance was tested experimentally by water absorption test and analysis of surface contact angles of cementitious mortar specimens. According to the results of this study, it can be stated that incorporation of nano polymer particles on the surface of cementitious mortar specimens can enhance contact angles and reduce water absorption by increasing hydrophobicity. However, a dosage limit exists for polymer materials in coating, and observed hydrophobic improvements decreases when polymer dosage reached beyond the limit. Additionally, it is observed that water absorption of polymer coated cementitious mortars is closely related with the results of surface contact angle.

A Clinical Study on the Development of a Simplified Fat Absorption Test by Simultaneous Administration of $^{125}I$-triolein and Chromic Oxide($^{51}Cr_2O_3$) ($^{125}I-triolein$$^{51}Cr_2O_3$의 동시투여(同時投與)에 의(依)한 지방흡수시험법(脂肪吸收試驗法)의 개발(開發)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Hong, Chang-Gi;Kim, Byung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.33-39
    • /
    • 1969
  • The conventional triolen absorption test has its defect in that the stool collection was cumbersome, time and energy-wasting. In the present study, the triolen absorption test was carried out using double tracer technique with $^{125}I-triolen\;and\;^{51}Cr_2O_3$ to determine if it can overcome the defect of the conventional method also with satisfactory results. Following were the results: 1. The clinical significance of this double tracer method was essentially the same with that previously done by radioactive. triolen alone. With the fractional fecal samples, the equation, y=0.626x+2.010 was substantiated, hence, this method appears to be clinically valuable if the appropriate correction is applied. With the mixed fecal samples, the equation y=0.642x+1.468 was substantiated (p<0.005) which appears to be also clinically valuable. When these two data were compared, the equation y=0.975x+0.090 (P<0.05) was substantiated, hence, $x{\fallingdotseq}y$. 2. The normal ranges of the fecal triolen excretion rate in this double tracer method were $3.46{\pm}1.69%$, namely, less than 6.9%. 3. The samplings were done from the first to third defecation in cases of clinically normal, and from the first to second defecation in cases of diarrhea or malabsorption. 4. The intestinal malabsorption of triolen was not observed in whom the triolen absorption was supposed to be clinically normal, however. a good number of suspicious malabsorptive cases showed the normal values.

  • PDF

ALC 의 내구성 및 물성개선에 관한 연구

  • 이범재;홍성수;황의환;조헌영;노재성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.65-70
    • /
    • 1993
  • The effect of particle size of Al powder, water repellent agent and finishing agent on frost resistance, absorption ratio and structure of micropore was examined to improve the physical properties and durability of ALC. According as the amount added of water repellent agent was increased, frost resistance was improved and absorption ratio was decreased. From one side freezing /thaw test, finishing agent which has a low vapor permeation located the crack at close indoor point of ALC specimen. ALC produced from fine Al powder has a low volume reduction by scalling and a sound appearance after freezing/thawing test and top surface freezing test, The crystal of tobermorite in ALC matrix was converted to calcium carbonate by carbonation which was accelerated with the decreasing of water content. Since the micropore of ALC was filled up by calcium carbonate, void ratio was reduced and crack was detected after complete carbonation.

  • PDF

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Investigation and Analysis of Regulations for the Safety of the Noise Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

Investigation and Analysis of Regulations for the Safety of the Sound Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF

Design on a new oil well test shock absorber under impact load

  • Wang, Yuanxun;Zhang, Peng;Cui, Zhijian;Chen, Chuanyao
    • Structural Engineering and Mechanics
    • /
    • v.28 no.3
    • /
    • pp.335-352
    • /
    • 2008
  • Continuous operation of test and measurement is a new operating technique in the petroleum exploitation, which combines perforation with test and measurement effectively. In order to measure the original pressure of stratum layer exactly and prevent testing instrument from being impaired or damaged, a suitable shock absorber is urgently necessary to research. Based on the attempt on the FEM analysis and experiment research, a new shock absorber is designed and discussed in this paper. 3D finite element model is established and simulated accurately by LS-DYNA, the effect and the dynamic character of the shock absorber impact by half sinusoidal pulse force under the main lobe frequency are discussed both on theoretics and experiment. It is shown that the new designed shock absorber system has good capability of shock absorption for the impact load.

A Study on the Heat Transfer in boiler through the performance test in thermal power plant (화력발전소 보일러내의 열전달에 관한 연구)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

The Effect of Seasoning on the Intestinal Absorption -Absorption by Passive Transport and the Effect of Red Pepper- (조미료가 창자 운동과 흡수기능에 미치는 영향 -소장의 피동적 흡수에 대한 고추의 영향-)

  • Shin, Dong-Hoon;Kim, Joong-Soo;Koh, Jae-Pyong;Ahn, Seung-Woon
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 1973
  • Numerous factors concern with the absorption of substances through the membrane of the gastrointestinal tract. To simplify the experimental condition, present work has been restricted to observe the disappearance rate of substance from the intestinal loop which was made in the jejunum, 70 cm apart from the pylorus of the adult rabbit. The purpose of the study is to clarify the absorption of urea through the jejunal wall is solely attributable to the concentration difference between the luminal fluid and plasma, and to observe the effect of adding red pepper upon the rate of absorption. The rabbits were anesthetized with nembutal, 35mg/kg I.V. Jejunal loop was made by ligating at 2 spots, 70 cm and 80cm apart from the pylorus. After rinsing with normal saline solution through the polyethylene tubing inserted from the end of the loop, 8 ml of test solution was placed through the same tubing. The test solution contained 200 mg% of urea and 150mg% of polyethylene glycol(M.W. 4,000) in normal saline solution. Right after placing the test solution the first specimen was taken through the tubing, and successive samplings were performed at 5, 10, 20, and 30 minutes. Logarithm of the difference of urea concentration between the luminal fluid and plasma was plotted against time elapsed after the onset of the experiment. If straight line is revealed, it would verify the nature of transport mechanism as diffusion, obeying the Fick's principle. The concentration of polyethylene glycol (PEG) was also measured in order to examine the change in the volume. PEG was used as the marker substance because it is not absorbable in the intestinal tract. Consequently the concentration of PEG relates inversely to the volume of the loop. Instantaneous concentration of urea in the loop times the volume will give the amount of urea remaining in the luminal fluid. The change in the amount of any substance is directly relate to the volume of the compartment and differs from the change in the concentration which is independent of the volume. After completion of the experiment without red pepper, it was added in the test solution and was centrifuged after thorough mixing. Supernatant of the mixture was placed in the loop and similar sampling were performed with the same time intervals that of previous run in order to observe the effects of the red pepper on the passive transport of the water soluble small substance, urea. The results obtained were as follows: 1. Logarithm of the concentration difference of urea between the luminal fluid and plasma was diminished exponentially as time elapsed. The decay constant in the experiment without red pepper was 0.0563/min. By adding red pepper in the test solution as much as the concentration rose to 4,000 mg% and 8,000 mg%, the decay constants were lowered to 0.0493/min and to 0.0506/min, respectively. The time interval by which the concentration difference dropped to one half of the initial value was prolonged. Without red pepper the half concentration time was 13.30 minutes, and by adding extract of red pepper, 15.31 minutes and 15.71 minutes were revealed. 2. The profile of the diminishing rate of tile amount of urea was quite different from that of the concentration because of the change in the volume of the loop during the observed period. 3. By adding the extract of red pepper, it slowed down the rate of absorption of urea in the intestinal loop, suggesting an increase in the diffusional barrier. 4. Larger dosage of red pepper brought an increase in the secretion of intestinal fluid with concomitant expansion of the luminal volume, and the retardation of the absorption of urea was noticed. This effect was largely dependent on the sensitivity of the individual animal to the red pepper, extract. The amount of urea remained after 10 minutes interval was 55.5% of the initial amount in the experiment without red pepper. On the other hand it was not consistent after administration of red pepper, showing 50.6% and 66.5% of the initial figures by adding 400 mg and 800 mg of red pepper in the test solution, respectively. It was postulated that symptom of diarrhea often encountered by taking a hot (red pepper) food might be attributable to the increase of secretion and the retardation of absorption in the intestinal tract.

  • PDF