• Title/Summary/Keyword: AO$_2$ System

Search Result 75, Processing Time 0.024 seconds

A Dynamic Analysis on the Relation between the amount of Review Time and the Effectiveness of the College Admission Officer System (입학사정관 심사시간과 전형효과에 대한 동태적 분석)

  • Juhn, Jae-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.113-123
    • /
    • 2012
  • In this paper, it is examined how the amount of review time per applicant to a college admission officer system is connected with the performance of the selected students after they enter the college. About five years ago, college admission officers system has been introduced to Korea as a government policy. Thus, for most Korean college, there is not enough number of admission officers, while it takes substantial time to find out whether an applicant has potential ability or not. Thus, it is required to find out some policy alternatives to solve this discrepancy. In this paper, a simulation model is built using System Dynamics theory and simulated to understand the relation between the amount of review time and the performance of the selected students. Finally, some implications and policy suggestions are derived from the simulation results.

Implementation of Tone Control Module in Anchor System for Improved Audio Quality

  • Seungwon Lee;Soonchul Kwon;Seunghyun Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.10-21
    • /
    • 2024
  • Recently, audio systems are changing the configuration of conventional sound reinforcement (SR) systems and public address (PA) systems by using audio over IP (AoIP), a technology that can transmit and receive audio signals based on internet protocol (IP). With the advancement of IP technology, AoIP technologies are leading the audio market and various technologies are being released. In particular, audio networks and control hierarchy over peer-to-peer (Anchor) technology based on AoIP is a system that transmits and receives audio signals over a wide bandwidth without an audio mixer, creating a novel paradigm for existing audio system configurations. Anchor technology forms an audio system by connecting audio sources and output equipment with On-site audio center (OAC), a device that can transmit and receive IP. Anchor's receiving OAC is capable of receiving and mixing audio signals transmitted from different IPs, making it possible to configure a novel audio system by replacing the conventional audio mixer. However, Anchor technology does not have the ability to provide audio effects to input devices such as microphones and instruments in the audio system configuration. Due to this, when individual control of each audio source is required, there is a problem of not being able to control the input signal, and it is impossible to individually affect a specific input signal. In this paper, we implemented a tone control module that can individually control the tone of the audio source of the input device using the audio processor core in the audio system based on Anchor technology, tone control for audio sources is possible through a tone control module connected to the transmitting OAC. As a result of the study, we confirmed that OAC receives the signal from the audio source, adjusts the tone and outputs it on the tone control module. Based on this, it was possible to solve problems that occurred in Anchor technology through transmitting OAC and tone control modules. In the future, we hope that the audio system configuration using Anchor technology will become established as the standard for audio equipment.

Construction and Expression of Mutant cDNAs Responsible for Genetic Polymorphism in Aldehyde Oxidase in Donryu Strain Rats

  • Adachi, Mayuko;Itoh, Kunio;Masubuchi, Akiko;Watanabe, Nobuaki;Tanaka, Yorihisa
    • BMB Reports
    • /
    • v.40 no.6
    • /
    • pp.1021-1027
    • /
    • 2007
  • We demonstrated the genetic polymorphism of aldehyde oxidase (AO) in Donryu strain rats: the ultrarapid metabolizer (UM) with nucleotide mutation of (377G, 2604C) coding for amino acid substitution of (110Gly, 852Val), extensive metabolizer (EM) with (377G/A, 2604C/T) coding for (110Gly/Ser, 852Val/Ala), and poor metabolizer (PM) with (377A, 2604T) coding for (110Ser, 852Ala), respectively. The results suggested that 377G > A and/or 2604C > T should be responsible for the genetic polymorphism. In this study, we constructed an E. coli expression system of four types of AO cDNA including Mut-1 with (377G, 2604T) and Mut-2 with (377A, 2604C) as well as naturally existing nucleotide sequences of UM and PM in order to clarify which one is responsible for the polymorphism. Mut-1 and Mut-2 showed almost the same high and low activity as that of the UM and PM groups, respectively. Thus, the expression study of mutant AO cDNA directly revealed that the nucleotide substitution of 377G > A, but not that of 2604C > T, will play a critical role in the genetic polymorphism of AO in Donryu strain rats. The reason amino acid substitution will cause genetic polymorphism in AO activity was discussed.

A Cooled Deformable Bimorph Mirror for a High Power Laser

  • Lee Jun-Ho;Lee Young-Cheol;Kang Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Adaptive optics (AO) has been applied in various fields including astronomy, ophthalmology and high power laser systems. An adaptive optics system for a high power laser is not significantly different from other AO systems in the point of configuration except that high energy absorbed by the deformable mirror distorts the deformable mirror surface and so degrades system performance. Currently we are researching a bimorph deformable mirror for beam cleaning of a high power class laser. The bimorph mirror was considered to have 99% reflective coating and 1% absorption. So this paper first presents the temperature profiles and corresponding thermal distortions of the bimorph mirror faceplate when the mirror is under a high power lasing for 10 seconds. The analysis was accomplished by the use of finite difference and finite element computer programs to generate the element arrays, calculate the temperature profiles, and determine the structural deformations. Then this paper proposes an 'embedded wafer' type water-cooling system with derived cooling parameters.

The Global Warming Hiatus Simulated in HadGEM2-AO Based on RCP8.5 (HadGEM2-AO RCP8.5 모의에서 나타난 지구온난화 멈춤)

  • Wie, Jieun;Moon, Byung-Kwon;Kim, Ki-Young;Lee, Johan
    • Journal of the Korean earth science society
    • /
    • v.35 no.4
    • /
    • pp.249-258
    • /
    • 2014
  • Despite the greenhouse gases like carbon dioxide have steadily increased in atmosphere, the overall trend of the global average surface air temperature has stalled during the last decade (2002-present). This phenomenon is often called hiatus or warming pause, which is challenging the prevailing view that anthropogenic forcing causes warming environment. Our study characterized the hiatus by analyzing the HadGEM2-AO (95 yrs) simulation data based on RCP8.5 scenario. The PC2 time series from the EOF of the zonal mean vertical ocean temperature has been defined as the index that represents the warming pause. The relationship between the hiatus, ENSO and the changes in climate system are identified by utilizing the newly defined PC2. Since the La Nina index (defined as the negative of NINO3 index) leads PC2 by about 11 months, it may be possible that the La Nina causes the warming to be interrupted. We also show that the cooling of the climate system closed tied to the heat penetration into the deep ocean, indicating the weakening the warming rate is due to the oceanic heat uptake. Finally, the global warming hiatus is characterized by the anomalous warming in Arctic region as well as the intensification of the trade wind in the equatorial Pacific.

Aggregation and Dissolution of Cationic Dyes with an Anionic Surfactant

  • Park, Joon-Woo;Chung, He-SSon
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.113-116
    • /
    • 1986
  • Spectral behaviors of cationic dyes, methylene blue(MB) and acridine orange(AO), with varying concentrations of sodium dodecylsulfate(SDS) were studied. At low concentration of SDS(<1mM), these dyes formed insoluble dye-surfactant aggregates. When [SDS] is 4-5 mM, the aggregates were dissolved into mixed micelles of constant composition. At higher concentration of [SDS], the composition of mixed micelles were changed with [SDS], resulting only monomeric form of dyes in micelles. AO-SDS system showed greater aggregating and less dissolving properties, and weaker effect of salt than MB-SDS system did. These were attributed to the greater hydrophobic nature of the former dye. The monomer/dimer ratios of dyes in mixed micelles at given [SDS] were greatest at $20^{\circ}C$, reflecting the dependency of CMC of the surfactant on temperature.

The Effect of Postural Training through Action Observation on Craniovertebral Angle and Cranial Rotation Angle of Forward Head Posture (동작관찰훈련을 통한 자세교육이 머리전방자세의 머리척추각과 머리회전각에 미치는 영향)

  • Shon, Myung-Ju;Roh, Jung-Suk;Choi, Houng-Sik;Oh, Dong-Sik
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.2
    • /
    • pp.17-24
    • /
    • 2012
  • Purpose : The purpose of this study was to show the effect of postural training through action observation (AO) on craniovertebral angle (CVA) and cranial rotation angle (CRA) of forward head posture (FHP). Methods : From 16 subjects of having the FHP who consist of postural training through the AO (n = 8) and control group (n = 8) were training to three times per one week during three weeks. FHP measurements for pre and post the intervention use to Wiz-pacs(Wiz-Picture Achiving Communication System) from X-ray change of CVA and CRA. Results : The study for the change within the group pre and post the intervention, CVA and CRA were found the significant differences only in the postural training group through the AO (p<.05). In the comparison of the rates of change between the groups pre and post the intervention CVA and CRA all showed the significant differences (p<.05), and in the comparison of the rates of average change of individual variables in each groups, the postural training group through the AO showed more change rates. Conclusion : The study suggests that when people with FHP received the postural training, the postural training through the AO resulted in more change into the correct postures.

  • PDF

A Circular Bimorph Deformable Mirror for Circular/Annulus/Square Laser Beam Compensation

  • Lee J.H.;Lee Y.C.;Cheon H.J.
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • We are studying the application of an adaptive optics system to upgrade the beam quality of a laser. The adaptive optics (AO) system consists of a bimorph deformable mirror, a Shack-Hartmann sensor and a control system. In most AO applications, the beam aperture is considered to be circular. However, in some cases such as laser beams from unstable resonators, the beam apertures are annulus or a holed-rectangle. In this paper, we investigate how well a bimorph deformable mirror of ${\Phi}120\;mm$ clear aperture can compensate phase distortions for three different beam configurations; 1) ${\Phi}120\;mm$ circular aperture, 2) ${\Phi}100\;mm$ annulus aperture with a ${\Phi}20\;mm$ hole and 3) $70\;mm{\times}70\;mm$ square aperture with a hole of $30\;mm{\times}30\;mm$. This study concludes that the bimorph mirror, which might be considered as a modal controller, can compensate tilt, defocus, coma and astigmatism, and spherical aberration for all three beams.

A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China- (인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로-)

  • Back, Seong-Kyung;Lee, Seung-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.