Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Automatic Bone Segmentation from CT Images Using Chan-Vese Multiphase Active Contour

  • Truc, P.T.H.;Kim, T.S.;Kim, Y.H.;Ahn, Y.B.;Lee, Y.K.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.713-720
    • /
    • 2007
  • In image-guided surgery, automatic bone segmentation of Computed Tomography (CT) images is an important but challenging step. Previous attempts include intensity-, edge-, region-, and deformable curve-based approaches [1], but none claims fully satisfactory performance. Although active contour (AC) techniques possess many excellent characteristics, their applications in CT image segmentation have not worthily exploited yet. In this study, we have evaluated the automaticity and performance of the model of Chan-Vese Multiphase AC Without Edges towards knee bone segmentation from CT images. This model is suitable because it is initialization-insensitive and topology-adaptive. Its segmentation results have been qualitatively compared with those from four other widely used AC models: namely Gradient Vector Flow (GVF) AC, Geometric AC, Geodesic AC, and GVF Fast Geometric AC. To quantitatively evaluate its performance, the results from a commercial software and a medical expert have been used. The evaluation results show that the Chan-Vese model provides superior performance with least user interaction, proving its suitability for automatic bone segmentation from CT images.

The evaluate the usefulness of various CT kernel applications by PET/CT attenuation correction (PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가)

  • Lee, Jae-Young;Seong, Yong-Jun;Yoon, Seok-Hwan;Park, Chan-Rok;Lee, Hong-Jae;Noh, Kyung-Wun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.37-43
    • /
    • 2017
  • Purpose Recently PET/CT image's attenuation correction is used CTAC(Computed Tomgraphy Attenuation Correction). it can quantitative evaluation by SUV(Standard Uptake Value). This study's purpose is to evaluate SUV and to find proper CT kernel using CTAC with applied various CT kernel to PET/CT construction. Materials and Methods Biograph mCT 64 was used for the equipment. We were performed on 20 patients who had examed at our hospital from february through March 2017. Using NEMA IEC Body Phantom, The data was reconstructed PET/CT images with CTAC appiled various CT kernel. ANOVA was used to evaluated the significant difference in the result. Results The result of measuring the radioactivity concentration of Phantom was B45F 96% and B80F 6.58% against B08F CT kernel, each respectively. the SUVmax increased to B45F 0.86% and B80F 6.54% against B08F CT kernel, In case of patient's parts data, the Lung SUVmax increased to B45F 1.6% and B80F 6.6%, Liver SUVmax increased to B45F 0.7% and B80F 4.7%, and Bone SUVmax increased to B45F 1.3% and B80F 6.2%, respectively. As for parts of patient's about Standard Deviation(SD), the Lung SD increased to B45F 4.2% and B80F 15.4%, Liver SD increased to B45F 2.1% and B80F 11%, and Bone SD increased to B45F 2.3% and B80F 14.7%, respectively. There was no significant difference discovered in three CT kernel (P >.05). Conclusion When using increased noise CT kernel for PET/CT reconstruction, It tends to change both SUVmax and SD in ROI(region of interest), Due to the increase the CT kernel number, Sharp noise increased in ROI. so SUVmax and SD were highly measured, but there was no statistically significant difference. Therefore Using CT kernel of low variation of SD occur less variation of SUV.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF