An HPLC-UV-based quantitative analytical method for Chrysanthemum morifolium: development, validation, and application

  • Jung, Dasom;Jin, Yan;Kang, Seulgi;Lee, Heesoo;Park, Keunbae;Li, Ke;Kim, Jin Hak;Geum, Jeong Ho;Lee, Jeongmi
    • Analytical Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.139-146
    • /
    • 2019
  • A simple and reliable analytical method based on high-performance liquid chromatography-ultraviolet detection was established for the analysis of the flowers of Chrysanthemum morifolium (CM). Luteolin-7-O-glucoside (LU7G) was chosen as a target analyte considering its content, availability, and ease of analysis. Chromatographic separation of LU7G was achieved using a Phenomenex Gemini $C_{18}$ column ($250{\times}4.6mm$, $5{\mu}m$) run with a mobile phase consisting of 0.5 % acetic acid in water and 0.5 % acetic acid in acetonitrile at a flow rate of $1.0mL\;min^{-1}$. The detection wavelength and column temperature were set at 350 nm and $40^{\circ}C$, respectively. Method validation was performed according to the AOAC guidelines and the method was specific, linear ($R^2=0.9991$ for $50-300{\mu}g\;mL^{-1}$), precise (${\leq}3.91%$RSD), and accurate (100.1-105.7 %). The limits of detection and quantification were 3.62 and $10.96{\mu}g\;mL^{-1}$, respectively. The established method was successfully applied to determine the contents of LU7G in various batches of bulk CM extracts and labscale CM extract. The developed method is a readily applicable method for the quality assessment of CM and its related products.

Measurement of Heat Transfer Coefficient of Magnesium Alloy and Temperature Change of Roll using Heat Transfer Solidification Analysis Method (전열응고해석법을 이용한 마그네슘합금의 열전달계수 및 롤의 온도변화 측정)

  • Han, Chang-Suk;Lee, Chan-Woo
    • Korean Journal of Materials Research
    • /
    • v.32 no.9
    • /
    • pp.391-395
    • /
    • 2022
  • Research is being actively conducted on the continuous thin plate casting method, which is used to manufacture magnesium alloy plate for plastic processing. This study applied a heat transfer solidification analysis method to the melt drag process. The heat transfer coefficient between the molten magnesium alloy metal and the roll in the thin plate manufacturing process using the melt drag method has not been clearly established until now, and the results were used to determine the temperature change. The estimated heat transfer coefficient for a roll speed of 30 m/min was 1.33 × 105 W/m2·K, which was very large compared to the heat transfer coefficient used in the solidification analysis of general aluminum castings. The heat transfer coefficient between the molten metal and the roll estimated in the range of the roll speed of 5 to 90 m/min was 1.42 × 105 to 8.95 × 104 W/m2·K. The cooling rate was calculated using a method based on the results of deriving the temperature change of the molten metal and the roll, using the estimated heat transfer coefficient. The DAS was estimated from the relationship between the cooling rate and DAS, and compared with the experimental value. When the magnesium alloy is manufactured by the melt drag method, the cooling rate of the thin plate is in the range of about 1.4 × 103 to 1.0 × 104 K/s.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

A Study on the In-process Measurement of Metallic Surface roughness in Cylindrical Grinding by Diode Laser (원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.1-8
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens a detecting unit with polygon mirror and CCD array sensor. and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultanilusly monitor the state of the grind wheel. The experimental results, showed that the increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min. the feed rate is 0.2m/min-0.9m/min, the dressing speed is 0.2mm/rev-0.4mm/rev, the stylus method and the in-process method can be obtained the same results. thus under limited working conditions. using the proposed system. the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

An Arithmetic System over Finite Fields

  • Park, Chun-Myoung
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.435-440
    • /
    • 2011
  • This paper propose the method of constructing the highly efficiency adder and multiplier systems over finite fields. The addition arithmetic operation over finite field is simple comparatively because that addition arithmetic operation is analyzed by each digit modP summation independently. But in case of multiplication arithmetic operation, we generate maximum k=2m-2 degree of ${\alpha}^k$ terms, therefore we decrease k into m-1 degree using irreducible primitive polynomial. We propose two method of control signal generation for the purpose of performing above decrease process. One method is the combinational logic expression and the other method is universal signal generation. The proposed method of constructing the highly adder/multiplier systems is as following. First of all, we obtain algorithms for addition and multiplication arithmetic operation based on the mathematical properties over finite fields, next we construct basic cell of A-cell and M-cell using T-gate and modP cyclic gate. Finally we construct adder module and multiplier module over finite fields after synthesizing ${\alpha}^k$ generation module and control signal CSt generation module with A-cell and M-cell. Next, we constructing the arithmetic operation unit over finite fields. Then, we propose the future research and prospects.

A Study on a Method for Computing the Powers and Inverses in GF($2^m$) (GF($2^m$) 상의 누승 및 역원을 구하는 방법에 관한 연구)

  • Park, Yong-Joon;Kang, Sung-Su;Kim, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1191-1194
    • /
    • 1987
  • This paper presents a method for computing the powers and inverse of an element in GF($2^m$). This method is based on the squaring algorithm $A^2=\sum\limits_{i=0}^{2m-2}P_i$, where $Pi={\alpha}_{i/2}$ if i is even, Pi=0 otherwise, derived from the multiplication algorithm for two elements in GF($2^m$). The powers and inverses in GF($2^m$) for m=2, 3, 4,5 were obtained using computer program, and used in circuit realization of Galois switching function. The squaring and inverse generating circuits are also shown.

  • PDF

An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction (기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구)

  • Cho Bong Suk;Jang Jae Bong;Kim Yong Ro;Kang Suk Pyo;Hong Sung Yun;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

Simultaneous determination for fungicide prochloraz and its metabolites in animal commodities with GC-ECD after hydrolysis (가수분해 후 GC-ECD를 이용한 축산물 중 살균제 Prochloraz 및 그의 대사물의 동시분석)

  • Park, Ji-Su;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.63 no.2
    • /
    • pp.153-159
    • /
    • 2020
  • The analytical method was established for simultaneous determination of fungicide prochloraz and its metabolites in several animal commodities using gas chromatography (GC) coupled with electron capture detector (ECD). Samples including beef meat, pork meat, chicken meat, milk, and egg were hydrolyzed with pyridine hydrochloride which converts prochloraz and its metabolites to 2,4,6-trichlorophenol (2,4,6-TCP) because residue definition for prochloraz was 'sum of prochloraz and its metabolites containing the 2,4,6-trichlorophenol moiety, expressed as prochloraz', for compliance with MRLs from animal commodities. Therefore, residual prochloraz was extracted with acetone, decomposed to 2,4,6-TCP, partitioned with dichloromethane, purified with aminopropyl SPE and quantified as 2,4,6-TCP with GC-ECD. The instrumental limit of quantitation and method LOQ (MLOQ) was 0.01 ㎍/mL and 0.02 mg/kg for prochloraz and 0.005 ㎍/mL and 0.01 mg/kg for 2,4,6-TCP, respectively. The linearity of the calibration curve was good with R2 >0.995 in the range of 0.005-0.2 ㎍/mL. Fortification levels of prochloraz were 0.02 mg/kg (MLOQ) and 0.2 mg/kg (10MLOQ) for recovery tests. Overall recoveries of prochloraz were >90% with <10% of coefficient variation (C.V.). This established analytical method was fully validated and could be useful for quantification of prochloraz and its metabolites in animal commodities as official analytical method.

A Selective Determination Method of Inorganic and Organic Mercury (무기수은과 유기수은의 선택정량)

  • Kim, Chon Han
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.8
    • /
    • pp.392-398
    • /
    • 1997
  • A method of selective determination of inorganic and organic mercury compounds has been described. The $CHCl_3$ solution of a high molecular quaternary alkylammonium salt, Aliquat 336 was used for the simultaneous preconcentration of both inorganic, $Hg^{2+}$ as its thiocyanate complex, and organic mercury compounds, $CH_3HgCl$ and $C_2H_3O_2$ $HgC_6H_5$ by extraction from their aqueous solution. Selective separation of the inorganic mercury from the extract was followed by stripping with 3 M $HClO_4 $ solution for the subsequent determination by CVAAS. Organic mercury was also determined by CVAAS after removal of $CHCl_3solvent$ from the extract and decomposition of the residue with 4% $KMnO_4 $-1 MH_2$S0_4$. The mixtures of inorganic and organic mercury compounds contained 1.0 $\mug$ as Hg in 50 mL of sample solution(0.02 ${\mu}gHg/mL$) were analysed within ${\pm}6%$ by absolute errors.

  • PDF