• Title/Summary/Keyword: 450 mm

Search Result 394, Processing Time 0.022 seconds

Influence of Depth of Rice Husk Litter on Broiler Performance, Litter Dampness and its Coccidial Oocyst Population During Winter

  • Mizu, M.M.R.;Chowdhury, S.D.;Karim, M.J.;Debnath, S.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.4
    • /
    • pp.450-454
    • /
    • 1998
  • Four groups each containing 48 seven-day-old broiler chicks were reared for 7 weeks during winter on rice husk litter spread to depths of 20, 30, 40 or 50 mm. Broiler performance was evaluated in terms of weight gain, feed consumption, feed efficiency and production number. Litter dampness was determined and coccidial oocyst populations were counted at different weeks of age. The depth of litter did not significantly affect live weight gain, feed consumption, feed conversion ratio, liveability or production number. Variation in moisture contents of litter was observed but the coccidial oocysts count per gramme of litter was within the safety level and therefore, there was no outbreak of coccidiosis in any group. Use of rice husk litter at different depths (20 to 50 mm) did not cause any breast blisters or leg abnormalities. It was concluded that rice husk can be used as litter at depths of between 20 and 50 mm during winter to raise broilers without affecting performance characteristics and health of birds.

전류인가형 부식 장치 개발

  • 임승수;김경진;정재필
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.22-22
    • /
    • 2002
  • 본 연구에서는 교량, 발전소, 산엽체의 시설물 둥 대형 옥외 설치 구조물의 부식방지를 위해, 전류 인가형 부식 방지 장치를 개발하였다. 기존의 전극기판(anode base)은 pve로 만들 어져 있어서, 옥외에 설치된 상태에서 쉽게 열화되어 부스러지며, 비 갠 후 시설물의 일부에 물기가 남아 있는 부식 환경하에서도 플라스틱 기판은 물기가 쉽게 제거되어 이마 건조된 상태가 된다. 이 경우에는 기판을 통해 부식방지 전류를 흐르게 할 수가 없기 때문에 희생 양극의 임무를 수행할 수가 없으며, 시설물이 부식되는 단점이 있다. 본 연구에서 개발한 흡습성 기판은 기존의 pve 기판의 단점을 개선한 것으로, 대기 중에 방치해도 수명이 영구적이며, 다공질이기 때문에 흡습성이 있어서 비 캔 후에도 기판 내부와 표면에 물기가 남아 었다. 따라서, 비 캔 후 부식환경에서도 부식 방지 전류를 흐르게 할 수가 있어서 희생양극의 업무를 수행할 수 있다. 본 연구에서는 옥외 구조물에 대한 방식 특성을 평가하기 위하여, 세라믹 기판을 부착하고 전류 측정을 하기 위한 철판(보통탄소강)구조물을 아래와 같이 제작하였다. 구조물의 $가로{\times}세로$ 크기는 $450mm{\times}450mm$ 이며, 구조물의 중앙에 세라믹 또는 pve Anode 기판을 부착 하였다. 살수 후 전류의 측정 위치는 구조물의 Anode 기판 중심에서 100mm 떨어진 지점 4 곳에 부착하였다. 본 연구에서 개발한 세라믹 가판의 경우와 기존의 pve 기판의 경우를 비 교 실험한 결과, 전자의 경우는 120분 경과 후에도 $70~80\mu\textrm{A}$의 많은 양의 전류가 흐르는 것으로 밝혀졌으며, 후자의 경우는 120분이 지난 후에는 전류가 전혀 흐르지 않는 것올 알 수 있다. 따라서, 기존의 pve 보다 세라믹 기판의 경우가 수분 흡수율이 높아 더 오랫동안 전류를 흐르게 하여 방식성이 개선된 것으로 판단된다.

  • PDF

The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm (내경 1.77 mm관내 R-22와 R-410A의 응축열전달)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 2008
  • The condensation heat transfer coefficients of R-22 and R-410A in a small diameter tube were investigated. The main components of the refrigerant loop consist of a receiver, a variable-speed pump, a mass flowmeter, an evaporator (preheater), and a condenser (test section). The test section consists of smooth, horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes varied from 450 to $1050\;kg/(m^2s)$ and the average inlet and outlet qualities were 0.05 and 0.95. The main results were summarized as follows : the condensation heat transfer coefficient also increases with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

  • PDF

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • v.5 no.5
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.

Implementation of AC Direct Driver Circuit for Ultra-slim LED Flat Light System (초슬림 LED 면조명 기구용 교류 직결형 구동 회로 구현)

  • Cho, Myeon-Gyun;Choi, Hyo-Sun;Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4177-4185
    • /
    • 2012
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent lamps because of its eco-friendly characteristics. LEDs are also actively used to design green building system and to make outdoor billboard as a back-light system due to its high energy efficiency. In this paper, we have developed AC direct driver for $12{\times}12$ FLB(flexible LED board) and LED flat light without SMPS. It has LID-PC-R101B driver IC that can support the high power factor and be composed of LED switching circuit in group. Also, an elaborate system designs can guarantee a high luminous efficiency, a high reliability and a low power consumption. The proposed FLB has the ultra slim shape of $450{\times}450$ mm, width of 4 mm and weight of 280 g. In the end, we have developed a prototype of FLB for billboard and flat light for room lighting with AC direct driver iposrder to verify the performance of the proposed system.

Evaluation of Axial Behavior of Columns Strengthened with Different Transverse Reinforcements in Jacket Section (확대단면에서의 띠철근 배근 방법에 따른 보강 기둥의 중심 축하중 거동 평가)

  • Hwang, Yong-Ha;Yang, Keun-Hyeok;Sim, Jae-Il;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.81-88
    • /
    • 2018
  • The present study evaluated the effective arrangement approach of transverse reinforcement in the jacket section for seismic strengthening of reinforced concrete columns. To simulate the full-scale columns, the section dimensions were determined as $450{\times}450mm$ for non-seismic existing columns and $750{\times}750mm$ for section enlargement strengthening columns. Over-lapped channel-shape bars and prefabricated bar units were proposed for closed-hoops in the jacket section, and conventional cross-ties anchored into existing columns and V-ties were considered for the supplementary ties. Test results showed that the axial capacity of the existing column and section enlargement columns with over-lapped channel-shape hoops was similar to the nominal strength calculated using ACI 318-14 procedure whereas the section enlargement column with prefabricated bar units possessed 1.25 times higher axial capacity than the nominal prediction. Furthermore, the axial ductility ratio of the section enlargement column with prefabricated bar unit was 139% higher than that of the existing column despite the potential size effect on ductility of concrete. Thus, it can be concluded that the developed prefabricated bar unit technique is practically useful for preventing the premature buckling of longitudinal reinforcement and confining core concrete in the section enlargement strengthening columns.

Implementation of an RF Module for 2.4GHz Wireless Audio/Video Transmission (2.4GHz 무선 음성/영상 송신용 RF 모듈 구현)

  • 김거성;권덕기;박종태;유종근
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.55-58
    • /
    • 2002
  • This paper describes an RF module for 2.4GHz wireless audio/video transmission. The pre-processed baseband input signals are FM-modulated using a VCO and then transmitted through an antenna after RF filtering. The designed circuits are implemented using a Teflon board of which the size is 52mm${\times}$62mm. The measured maximum output signal levels are around -3dBm and the harmonics are less than -450dBc. The manufactured module consumes 130mA from a 8V supply.

  • PDF

A Study on the Microcomputer Based Infusion Pump (의료용 Infusion Pump 개발에 관한 연구)

  • 이경중;이윤선
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 1984
  • The Infusion pump that is widely used in hospital has been designed. This system consists of microcomputer system, stepping motor control part and mechanical part for syringe driving. It has 450mmHg maximum pressure and $\pm$0.5% accuracy, and and especially keep the accent on the electrical and functional safety.

  • PDF

MSC(Multi-Spectral Camera) 열제어 시스템 소개

  • Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk;Jang, Young-Jun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.107-116
    • /
    • 2005
  • As a unique payload of Komsat-2, MSC, comprising EOS(Electro-Optical Sub-system), PMU(Payload Management Unit) and PDTS(Payload Data Transmission Sub-system), is supposed to take pictures of one panchromatic and 4 multi-spectral image between wavelength 450mm~900mm, and is being under final Satellite I&T. It will perform the earth remote sensing with applications such as acquisition of high resolution images, surveillance of large scale disasters and its countermeasure, survey of natural resources, etc.. Under the hostile influence of the extreme space environmental conditions due to deep space and direct solar flux, the thermal design is especially of major importance in designing a payload. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy source on the spacecraft. This paper describes details of thermal control system for MSC.

  • PDF

Lockeia gigantus ichnosp. nov. in the Lacustrine Deposits of the Early Cretaceous Jinju Formation, Southern Coast of Korea (남해안 전기 백악기 진주층의 호성 퇴적층에서 산출된 Lockeia gigantus ichnosp. nov.)

  • Kim, Kyung-Soo;Kim, Jeong-Yul
    • Journal of the Korean earth science society
    • /
    • v.29 no.1
    • /
    • pp.13-28
    • /
    • 2008
  • About 450 specimens of Lockeia were discovered from the lacustrine siltstone of the Early Cretaceous Jinju Formation of Jin Island, southern coast of Korea. They are very elongated, seed-shaped Lockeia characterized by a large size, mostly 60-70 mm long and 15-20 mm wide. They are characteristically sharp longitudinal furrow bounded by steeply inclined both margins, elevated marginal rims and sharp pointed both longitudinal furrow ends. This trace fossil is herein described as Lockeia gigantus ichnosp. nov. Plicatounio, a freshwater bivalve which does not occur occurs occasionally within Lockeia gigantus is regarded as the most-likely producer of this resting trace fossil. This new trace fossil represents the largest Lockeia ever known and the first record of Lockeia from the Cretaceous non-marine deposits in the world. This fossil also represents an unusual example of resting trace fossil (Lockeia) associated with a possible producer (bivalve Plicatounio) lived in community in the shallow lacustrine environment.