• Title/Summary/Keyword: 3d depth image

Search Result 615, Processing Time 0.032 seconds

Experimental Study on Hydrodynamic Characteristics of Dam Break Flow for Estimation of Green Water Loading (청수현상 추정을 위한 댐 붕괴 흐름의 유체동역학적 특성에 관한 실험적 연구)

  • Hyung Joon Kim;Jong Mu Kim;Jae Hong Kim;Kwang Hyo Jung;Gang Nam Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • In this study, hydrodynamic characteristics of dam break flow were investigated by a series of experiments. The experiments were performed in a 2-D rectangular flume with obtaining instantaneous images of dam break flow to capture the free surface elevation, and pressure distributions on vertical wall and bottom of the flume. The initial water depth of the dam break flow was changed into 3 different heights, and the gate opening speed was changed during the experiments to study the effect of the gate speed in the dam break flow. Generation of dam break phenomena could be classified into three stages, i.e., very initial, relatively stable, and wall impact stages. The wall impact stage could be separated into 4 generation phases of wall impinge, run-up, overturning, and touchdown phases based on the deformation of the free surface. The free surface elevation were investigated with various initial water depth and compared with the analytic solutions by Ritter (1892). The pressures acting on the vertical wall and bottom were provided for the whole period of dam break flow varying the initial water depth and gate open speed. The measurement results of the dam break flow was compared with the hydrodynamic characteristics of green water phenomena, and it showed that the dam break flow could overestimate the green water loading based on the estimation suggested by Buchner (2002).

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement (실리콘 광증폭기와 반응깊이 측정방법을 이용한 수술용 베타 영상/감마 프로브 가능성 연구)

  • Kwak, In-Suk;Kang, Han Gyu;Son, Jeong-Whan;Lee, Jae Sung;Hong, Seong Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

Usability of CPR Training System based on Extended Reality (확장현실 기반의 심폐소생술 교육 시스템의 사용성 평가)

  • Lee, Youngho;Kim, Sun Kyung;Choi, Jongmyung;Park, Gun Woo;Go, Younghye
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.6
    • /
    • pp.115-122
    • /
    • 2022
  • Recently, the importance of CPR training for the layperson has been emphasized to improve the survival rate of out-of-hospital cardiac arrest patients. An accurate and realistic training strategy is required for the CPR training effect for laypersons. In this study, we develop an extended reality (XR) based CPR training system and evaluate its usability. The XR based CPR training system consisted of three applications. First, a 3D heart anatomy image registered to the manikin is transmitted to the smart glasses to guide the chest compression point. The second application provides visual and auditory information about the CPR process through smart glasses. At the same time, the smartwatch sends a vibration notification to guide the compression rate. The 'Add-on-kit' is a device that detects the depth and speed of chest compression via sensors installed on the manikin and sends immediate feedback to the smartphone. One hundred laypersons who participated in this study agreed that the XR based CPR training system has realism and effectiveness. XR based registration technology will contribute to improving the efficiency of CPR training by enhancing realism, immersion, and self-directed learning.

The effect of viewing distance and the speed of motion-in-depth on visual fatigue (시각적 피로도에 영향을 미치는 시청거리와 깊이방향의 운동속도)

  • Kham, Kee-Taek;Li, Hyung-Chul;Lee, Seung-Hyun
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.169-180
    • /
    • 2009
  • The present study have investigated the effect of the characteristics of stereoscopic images and viewing environment on visual fatigue. We manipulated the speed of stereo images with motion-in-depth and viewing distance, which were used as representative variables of the characteristics of stereo image and viewing environment, respectively. Visual fatigue was evaluated with use of a subjective questionnaire which is consisting of 5 different and independent factors: "Eye pain", "Visual stress," "Nauseousness", "Body stiffness", and "Blurriness". In general, when viewing time increased from 10 minutes to 20 and 40 minutes, observers felt severe visual fatigue. Among other factors, only the factor score of "Nauseousness" was significantly increased as the speed of object moving in depth became faster. When viewing distance was increased, the score of "Blurriness" was decreased. These results suggest that different kind of the visual fatigue might be induced depending on characteristics of the stereo images and viewing environment.

  • PDF

Multimodal Nonlinear Optical Microscopy for Simultaneous 3-D Label-Free and Immunofluorescence Imaging of Biological Samples

  • Park, Joo Hyun;Lee, Eun-Soo;Lee, Jae Yong;Lee, Eun Seong;Lee, Tae Geol;Kim, Se-Hwa;Lee, Sang-Won
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.551-557
    • /
    • 2014
  • In this study, we demonstrated multimodal nonlinear optical (NLO) microscopy integrated simultaneously with two-photon excitation fluorescence (TPEF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) in order to obtain targeted cellular and label-free images in an immunofluorescence assay of the atherosclerotic aorta from apolipoprotein E-deficient mice. The multimodal NLO microscope used two laser systems: picosecond (ps) and femtosecond (fs) pulsed lasers. A pair of ps-pulsed lights served for CARS (817 nm and 1064 nm) and SHG (817 nm) images; light from the fs-pulsed laser with the center wavelength of 720 nm was incident into the sample to obtain autofluorescence and targeted molecular TPEF images for high efficiency of fluorescence intensity without cross-talk. For multicolor-targeted TPEF imaging, we stained smooth-muscle cells and macrophages with fluorescent dyes (Alexa Fluor 350 and Alexa Fluor 594) for an immunofluorescence assay. Each depth-sectioned image consisted of $512{\times}512$ pixels with a field of view of $250{\times}250{\mu}m^2$, a lateral resolution of $0.4{\mu}m$, and an axial resolution of $1.3{\mu}m$. We obtained composite multicolor images with conventional label-free NLO images and targeted TPEF images in atherosclerotic-plaque samples. Multicolor 3-D imaging of atherosclerotic-plaque structural and functional composition will be helpful for understanding the pathogenesis of cardiovascular disease.

3D Visual Attention Model and its Application to No-reference Stereoscopic Video Quality Assessment (3차원 시각 주의 모델과 이를 이용한 무참조 스테레오스코픽 비디오 화질 측정 방법)

  • Kim, Donghyun;Sohn, Kwanghoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.110-122
    • /
    • 2014
  • As multimedia technologies develop, three-dimensional (3D) technologies are attracting increasing attention from researchers. In particular, video quality assessment (VQA) has become a critical issue in stereoscopic image/video processing applications. Furthermore, a human visual system (HVS) could play an important role in the measurement of stereoscopic video quality, yet existing VQA methods have done little to develop a HVS for stereoscopic video. We seek to amend this by proposing a 3D visual attention (3DVA) model which simulates the HVS for stereoscopic video by combining multiple perceptual stimuli such as depth, motion, color, intensity, and orientation contrast. We utilize this 3DVA model for pooling on significant regions of very poor video quality, and we propose no-reference (NR) stereoscopic VQA (SVQA) method. We validated the proposed SVQA method using subjective test scores from our results and those reported by others. Our approach yields high correlation with the measured mean opinion score (MOS) as well as consistent performance in asymmetric coding conditions. Additionally, the 3DVA model is used to extract information for the region-of-interest (ROI). Subjective evaluations of the extracted ROI indicate that the 3DVA-based ROI extraction outperforms the other compared extraction methods using spatial or/and temporal terms.

지구물리탐사자료의 지리정보시스템 해석

  • Han, Su-Hyeong;Kim, Ji-Su;Sin, Jae-U;Gwon, Il-Ryong
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.1
    • /
    • pp.29-39
    • /
    • 2002
  • Geophysical data sets from the Chojeong area in the Chungbok-Do are compositely studied in terms of multi-attribute interpretations for the subsurface mappings of shallow fracture zones, associated with groundwater reservoir. Utilizing a GIS software, the attribute data were implemented to a database; a lineament from the satellite image, electrical resistivities and its standard deviation, radioactivity, seismic velocity, and bedrock depth. In an attempt to interpret 1-D electrical sounding data in 3-D views, 1-D data are firstly performed horizontal and vertical inter- and extrapolation. Reconstruction of a resistivity volume is found to be an effective scheme for subsurface mapping of shallow fracture zones. Shallow fracture zones are located in the southeastern part of the study area, which are commonly correlated with the various exploration data.

  • PDF

Partial Parallax Adjustment of Stereo Image by Manipulating Depth Map (깊이영상 조작에 의한 스테레오 영상의 부분 시차 조정)

  • Lee, Jaewon;Bae, Yun-Jin;Kim, Kang-San;Lee, Cheol-Hee;Jin, Kyung-A;Seo, Hyun-Kyo;Lee, Ho-Keun;Kim, Hyung-Suk;Choi, Hyun-Jun;Seo, Young-Ho;Yoo, Ji-Sang;Kim, Dong-Wook
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.311-314
    • /
    • 2010
  • 최근 3D 영상에 대한 대중화가 급속히 진행되고 있음에도 불구하고 한 번 만들어진 영상/비디오를 재사용하거나 조작하여 다양한 형태의 콘텐츠를 만들지 못하고 있다. 본 논문에서는 깊이영상과 양안(스테레오) 영상 또는 깊이영상과 단안 영상이 주어졌다고 가정하고 깊이영상을 조작하여 양안 시차(parallax)를 변화시키는 방법을 제안한다. 시차변화의 대상은 부분영상이며, 특정 개체를 추출하여 깊이정보를 수정하고, 이를 바탕으로 스테레오 영상을 재구성한다. 본 논문에서는 정지영상만을 대상으로 하며, 동일한 방법을 동영상에 적용하면 동영상 또한 시차를 변화시킨 결과를 얻을 수 있다. 실험은 Middlebury의 테스트 영상들을 대상으로 제안한 방법을 적용하여 자연스러운 스테레오 영상을 얻을 수 있음을 보인다.

  • PDF