• Title/Summary/Keyword: 3D profiles

Search Result 766, Processing Time 0.022 seconds

Performance Evaluation of Stealth Chamber as a Novel Reference Chamber for Measuring Percentage Depth Dose and Profile of VitalBeam Linear Accelerator (VitalBeam 선형가속기의 심부선량백분율과 측방선량분포 측정을 위한 새로운 기준 전리함으로서 스텔스 전리함의 성능 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee;Kang, Sang-Won;Kim, Kyeong-Hyeon;Jung, Jae-Yong;Shin, Young-Joo;Suh, Tae-Suk;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2018
  • The purpose of this study is to evaluate the performance of a "stealth chamber" as a novel reference chamber for measuring percentage depth dose (PDD) and profile of 6, 8 and 10 MV photon energies. The PDD curves and dose profiles with fields ranging from $3{\times}3$ to $25{\times}25cm^2$ were acquired from measurements by using the stealth chamber and CC 13 chamber as reference chamber. All measurements were performed with Varian VitalBeam linear accelerator. In order to assess the performance of stealth chamber, PDD curves and profiles measured with stealth chamber were compared with measurement data using CC13 chamber. For PPDs measured with both chambers, the dosimetric parameters such as $d_{max}$ (depth of maximum dose), $D_{50}$ (PDD at 50 mm depth), and $D_{100}$ (PDD at 100 mm depth) were analyzed. Moreover, root mean square error (RMSE) values for profiles at $d_{max}$ and 100 mm depth were evaluated. The measured PDDs and profiles between the stealth chamber and CC13 chamber as reference detector had almost comparable. For PDDs, the evaluated dosimetric parameters were observed small difference (<1%) for all energies and field sizes, except for $d_{max}$ less than 2 mm. In addition, the difference of RMSEs for profiles at $d_{max}$ and 100 mm depth was similar for both chambers. This study confirmed that the use of stealth chamber for measuring commission beam data is a feasible as reference chamber for fields ranging from $3{\times}3$ to $20{\times}20cm^2$. Furthermore, it has an advantage with respect to measurement of the small fields (less than $3{\times}3cm^2$ field) although not performed in this study.

Development of physically based 3D computer simulation code TRICSI for ion implantation into crystalline silicon

  • Son, Myung-Sik;Lee, Jun-Ha;Hwang, Ho-Jung
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • A new three-dimensional (3D) Monte Carlo ion implantation simulator, TRICSI, has been developed to investigate 3D mask effects in the typical mask structure for ion implantation into crystalline silicon. We present the mask corner and mask size effects of implanted boron range profiles, and also show the calculated damage distributions by applying the modified Kinchin-Pease equation in the single-crystal silicon target. The simulator calculates accurately and efficiently the implanted-boron range profiles under the relatively large implanted area, using a newly developed search algorithm for the collision partner in the single-crystal silicon. All of the typical implant parameters such as dose, tilt and rotation angles, in addition to energy can be used for the 3D simulation of ion implantation.

The Evaluation of Cylindrical Gear Measurement on Teeth Roots and Bottom Profiles in Different Sections (원통기어의 다단면 치형 측정평가)

  • Moon, Sung-Min;Kang, Jae-Hwa;Kido, Hiromitsu;Kurokawa, Syuhei;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.46-49
    • /
    • 2012
  • Gears are reliable and efficient power transmission elements. They have been widely used in all kinds of machinery. Nowadays, resource conservation energy conservation environmental improvements from the request of the compact, light weight, high efficiency, low cost Higher efficiency is required. Tooth root and bottom profiles of cylindrical gears affect bending fatigue life, but they are hard to measure with conventional gear measuring machine(GMM), because GMM is normally customized to measure only gear working flanks. The authors try to develop a new type of GMM by installing an extra 3D scanning probe and control software to measure tooth root and bottom profiles. First, in order to measure in various directions, a 3D scanning probe has been attached to the GMM developed. Next, calibration algorithm has been developed. Deviations of the calibration results are measured and it is found that systematic error must be caused by heat from driving motors. A new alternative GMM with driving motors generating less heat was designed and two GMMs are compared. Finally, 3 Dimension measurement of tooth root and bottom profiles of cylindrical gears is described.

A Study on 3-D Analytical Model of Ion Implanted Profile (이온 주입된 프로파일의 3-D의 해석적인 모델에 관한 연구)

  • Jung, Won-Chae;Kim, Hyung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.6-14
    • /
    • 2012
  • For integrated complementary metal oxide semiconductor (CMOS) circuits, the lateral spread for two-dimensional (2-D) impurity distributions are very important for the analyzing the devices. The measured two-dimensional SEM data obtained using the chemical etching-method matched very well with the results of the Gauss model for boron implanted samples. But the profiles in boron implanted silicon were deviated from the Gauss model. The profiles in boron implanted silicon were shown a little bit steep profile in the deep region due to backscattering effect on the near surface from the bombardments of light boron ions. From the simulated 3-D data obtained using an analytical model, the 1-D and 2-D data were compared with the experimental data and could be verified the justification from the experimental data. The data of 3-D model were also shown good agreements with the experimental and the simulated data. It can be used in the 3-D chip design and the analysis of microelectro-mecanical system (MEMS) and special devices.

New 3D failure analysis of water-filled karst cave beneath deep tunnel

  • Zhang, R.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • In this study, both 2D and 3D failure shapes of rock mass above the water-filled cavity are put forward when the surrounding rock mass cannot bear the pressure caused by the water-filled cavity. Based on the analytical expressions derived by kinematic approach, the profiles of active and passive failure patterns are plotted. The sensitivity analysis is conducted to explore the influences of different rock parameters on the failure profiles. During the excavation of the deep tunnels above the karst cavity, the water table always changes because of progressive failure of cavity roof. Therefore, it is meaningful to discuss the effects of varying water level on the failure patterns of horizontal rock layers. The changing laws of the scope of the failure pattern obtained in this work show good consistency with the fact, which could be used to provide a guide in engineering.

3-D Profile Measurement System of Live Human Faces for the '93 Taejon Expo Kumdori Robot Scupltor (93 대전엑스포 꿈돌이 조각가로보트의 인물형상 측정시스템)

  • 김승우;박현구;김문상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.670-679
    • /
    • 1995
  • This paper presents the 3-D profile measurement system of live human faces, which was developed specially for 'KUMDORI sculptor robot' of the '93 Taejon Exposition. '93 Taejon EXPO. The basic principle for measurement adopts the slit beam projection which is a method of measuring 3-D surface profiles using geometric optics between the slit beam and the CCD camera. Since the slit beam projection consumes long measuring time, it is unfit to measure the 3-D profiles of living objects as human. Therefore, the projection type slit beam method which consumes short measuring time is newly suggested. And an algorithm to reconstruct the 3-D profile from the deformed images using finite approximated calibration is suggested and practically implemented. The projection type slit beam method was applied to spectators in a period of '93 Taejon EXPO. The measurement results show that the technique is suitable for 3-D face profile measurement on a living body.

Changes in the thyroid hormone profiles in children with nephrotic syndrome

  • Jung, Sun Hee;Lee, Jeong Eun;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.3
    • /
    • pp.85-89
    • /
    • 2019
  • Purpose: We compared thyroid hormone profiles in children with nephrotic syndrome (NS) during the nephrotic phase and after remission. Methods: This study included 31 pediatric NS patients. The thyroid hormone profiles included serum levels of triiodothyronine (T3), thyroxine (T4), thyroid-stimulating hormone (TSH), and free T4. Results: Of the 31 patients, 16 (51.6%) showed abnormal thyroid hormone profiles: 6 had overt hypothyroidism, 8 had subclinical hypothyroidism, and 2 had low T3 syndrome. The mean serum T3, T4, and free T4 levels in the nephrotic phase and after remission were $82.37{\pm}23.64$ and $117.88{\pm}29.49ng/dL$, $5.47{\pm}1.14$ and $7.91{\pm}1.56{\mu}g/dL$, and $1.02{\pm}0.26$ and $1.38{\pm}0.23ng/dL$, respectively; the levels were significantly lower in the NS nephrotic phase (P=0.0007, P<0.0001, and P=0.0002). The mean serum TSH levels during the nephrotic phase and after remission were $8.05{\pm}3.53$ and $4.08{\pm}2.05{\mu}IU/mL$, respectively; they were significantly higher in the nephrotic phase (P=0.0005). The urinary protein/creatinine ratio during the nephrotic phase was significantly correlated with serum T3, T4, and free T4 levels (r=-0.5995, P=0.0032; r=-0.5797, P=0.0047; r=-0.5513, P=0.0078) as well as with TSH levels (r=0.5022, P=0.0172). A significant correlation was found between serum albumin and serum T3 levels during the nephrotic phase (r=0.5385, P=0.0018) but not between serum albumin and T4, TSH, or free T4 levels. These significant correlations all disappeared after remission. Conclusion: Abnormal thyroid hormone profile findings were observed in 51.6% of pediatric patients with NS. Thyroid hormone levels normalized after remission, regardless of levothyroxine therapy.

LUMINOSITY PROFILES OF dE AND dS0 GALAXIES IN THE VIRGO CLUSTER

  • Kim, Kyoo-Hyun;Lee, Kyung-Hoon;Ann, Hong-Bae
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.3
    • /
    • pp.57-71
    • /
    • 2006
  • We investigated the structural parameters of a sample of 30 dwarf galaxies(15 dEs and 15 dS0s) in the Virgo Cluster using i-band images from the Sloan Digital Sky Survey Data Release 4. Among 28 galaxies for which surface brightness profiles were derived from ellipse fittings, 23 galaxies had a single component that was adequately described by a generalized $S\acute{e}rsic$ function with a shape parameter ranging from n=0.5 to 2, while 5 galaxies(2 dEs and 3 dS0s) had bulge and disk components that were fitted by a generalized $S\acute{e}rsic$ function and an exponential function, respectively. Since the majority of dwarf galaxies in the present sample had a single component, it seems likely that genuine dS0 galaxies that have disk and bulge components are quite rare in the Virgo Cluster. The similarity in structural parameters of genuine dS0 galaxies in the Virgo Cluster with those of Magellanic-type galaxies implies that the progenitors of dwarf lenticular galaxies in the Virgo Cluster were most likely Magellanic-type galaxies if dS0s are harassed late-type spirals.

Activity Segmentation and 3D-Visualization of Pusher-Loaded Earthmoving Operations from Position Data

  • Ahn, Sanghyung;Dunston, Phillip S.;Kandil, Amr;Martinez, Julio C.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.328-332
    • /
    • 2015
  • By logging position data from GPS-equipped construction machines, we re-create daily activities as 3D animations to analyze performance and facilitate look-ahead scheduling. The 3D animation enables going back to any point in time and space to observe the activities as they took place. By segmenting data into a set of activities, it is possible to obtain actual measures of performance such as cycle times, production, speed profiles and idle times. The measures of performance can then be compared to those expected (e.g., theoretical speed profiles vs. observed profiles), and instances of significant difference can be flagged for further investigation. Idle times and queues that exceed prescribed thresholds can also be identified. In general, many of the traditional real-time performance analyses can be performed after the fact. Situations of interest can be identified automatically and the events in this manner enhances effective performance improvement in construction. The proposed research is explained and demonstrated using a real push-loaded earthmoving operation.

  • PDF

An Experimental Study on Swirling Flow in a Sudden Expansion Tube using 3D PIV Technique (3D PIV 기법을 이용한 선회유동의 급팽창에 관한 실험적 연구)

  • Chang, Tae-Hyun;Kil, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.272-281
    • /
    • 2009
  • The effect of swirl on the flow characteristics in a sudden expansion tube was examined experimentally by using 3D PIV(particle image velocimetry) to capture the velocity profiles. The swirling flow of water through a sudden 1:2 axisymmetric expansion has previously been studied experimentally within a horizontal round tube. A kind of tangential slot is used as a swirl generator for swirling flow and a honey comb is used for without swirl flow. The work with the swirl and without swirl results are compared to each other at the same Reynolds number. Liquid crystal was employed to measure temperature profiles and heating coil used for heat transfer with and without swirl flow. And then the Nusselt number ratoes(Nu/Nudb) are calculated along the test section.