• Title/Summary/Keyword: 3D Presentation

Search Result 216, Processing Time 0.024 seconds

Study on Recognitions of Department of Technology Education Professors Introducing 'Creative Engineering Design' Unit of Highschool Technology.Home Economics (고등학교 기술.가정 교과 '창의공학설계' 단원 신설에 따른 기술교육과 교수의 인식 분석)

  • Kim, Seong-Il
    • 대한공업교육학회지
    • /
    • v.39 no.1
    • /
    • pp.128-142
    • /
    • 2014
  • The purpose of this study was to provide a basis information for the education direction of 'creative engineering design' lesson to highschool students and pre-technology teachers by analyzing pre-experienced the d epartment of technology professors' recognitions, according to the newly opened unit 'creative engineering design' in 2009 revised highschool technology home economics education curriculum. The survey questionnaire was composed of 34 questions and collected from 16 department of technology education professors. The data was analyzed by SPSS program. The results of study were as follows : First, in 'creative engineering design' educational objectives, the highest average level(M) of response was problem solving ability, the opportunity of engineering experience and creativity improvement were followed. In the response about 'creative engineering design' educational contents, the average level(M) of the creative thinking method education was the highest(3.94). and the following important level was the write training education for presentation. Second, in the 'creative engineering design' educational areas, the professors preferred the idea conception, design, and production manufacturing area. In the teaching learning method, the average level(M) of design-based learning method was the first. and PBL, problem solving method were favored Third, in the 'creative engineering design' lesson manage, the secure of practice room and material cost, and the check of the progress situations were needed preferentially. In the education assessments, various and combined assessment preferred such as production, portfolio, and presentation. Fourth, in the pre-technology teachers' lesson of the university course, the product manufacturing level was preferred production to improve uncomfortable thing in life. The major difficulty in product manufacturing was the lack of major knowledge and product conception.

Introduction of KIER Pyrolysis Process and 3,000 ton/yr Demonstration Plant (KIER의 열분해유화 공정 기술과 실증플랜트 소개)

  • Shin, Dae-Hyun;Jeon, Sang-Gu;Kim, Kwang-Ho;Lee, Kyong-Hwan;Roh, Nam-Sun;Lee, Ki-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.479-482
    • /
    • 2008
  • Since late of 2000, KIER has developed a novel pyrolysis process for production of fuel oils from polymer wastes. It could have been possible due to large-scale funding of the Resource Recycling R&D Center. The target was to develop an uncatalyzed, continuous and automatic process producing oils that can be used as a fuel for small-scale industrial boilers. The process development has proceeded in three stages bench-scale unit, pilot plant and demonstration plant. As a result, the demonstration plant having capacity of 3,000 tons/year has been constructed and is currently under test operation for optimization of operation conditions. The process consisted of four parts ; feeding system, cracking reactor, refining system and others. Raw materials were pretreated via shredding and classifying to remove minerals, water, etc. There were 3 kind of products, oils(80%), gas(15%), carbonic residue(5%). The main products i.e. oils were gasoline and diesel. The calorific value of gas has been found to be about 18,000kcal/$m^3$ which is similar to petroleum gas and shows that it could be used as a process fuel. Key technologies adopted in the process are 1) Recirculation of feed for rapid melting and enhancement of fluidity for automatic control of system, 2) Tubular reactor specially-designed for heavy heat flux and prevention of coking, 3)Recirculation of heavy fraction for prevention of wax formation, and 4) continuous removal & re-reaction of sludge for high yield of main product (oil) and minimization of residue. The advantages of the process are full automation, continuous operation, no requirement of catalyst, minimization of coking and sludge problems, maximizing the product(fuel oil) yield and purity, low initial investment and operation costs and environment- friendly process. In this presentation, background of pyrolysis technology development, the details of KIER pyrolysis process flow, key technologies and the performances of the process will be discussed in detail.

  • PDF

Severe Anemia Due to Parvovirus Infection Following Treatment with Rituximab in a Pediatric Kidney Transplant Recipient : Anemia after Treatment of Rituximab in Kidney Recipient Patient

  • Kim, Seung Yun;Lee, Hyoung Jin;Park, Eujin;Ahn, Yo Han;Ha, Il-Soo;Cheong, Hae Il;Kang, Hee Gyung
    • Childhood Kidney Diseases
    • /
    • v.19 no.2
    • /
    • pp.176-179
    • /
    • 2015
  • Rituximab (RTX), a monoclonal antibody against the B-cell marker CD20, is commonly used as a treatment for antibody-mediated diseases or B-lymphocyte-mediated diseases. Destruction of B cells may reverse the disease course in many conditions; however, patients who are treated with RTX cannot respond appropriately to de novo infection due to lack of B lymphocytes. Here, we report one such case. A 7-year-old renal allograft recipient presented with severe anemia due to parvovirus infection after RTX treatment. The patient had focal segmental glomerulosclerosis and had received cadaveric kidney transplantation 6 months previously. She was treated with high-dose steroid for acute rejection and RTX for Epstein Barr Virus infection 3 months previously. At presentation, her hemoglobin level was 5.4 g/dL and leukocyte and platelet counts were normal. She had microcytic normochromic anemia and high viral load of parvovirus B19(70,578 copies/mL). Intravenous immunoglobulin ($200mg/kg{\cdot}d$) treatment controlled the progression of anemia and parvovirus infection. De novo parvovirus infection during the B lymphocyte-depletion period may have precipitated the severe anemia in this case. Close monitoring of infection is required after RTX therapy.

Identification of Job Competencies in Developing Human Resource;The Case of a Company which Provides a Preschool Education Program (인적자원 개발을 위한 직무역량 규명;학습지 기업을 대상으로)

  • Kim, Jin-Mo
    • Journal of Agricultural Extension & Community Development
    • /
    • v.8 no.2
    • /
    • pp.159-177
    • /
    • 2001
  • This research aims to clarify what kind of competencies are the source of the competitiveness of an enterprise and the standards for the development of human resources. Its specific objectives are the following; First, to develop methods for examining competencies to carry out one’s job. Second, to draw out the competencies necessary for carrying out the jobs by jobs on the basis of the developed methods. Third, to clarify the competencies commonly needed to carry out all kinds of jobs. This study collected materials for drawing out the competencies needed to perform 21 jobs in six job groups. This was done with the help of a panel of professionals. The process for drawing out the competencies required to perform certain job was designed in six steps. These steps combine classical methods using particular reference groups as well as model methods for particular job competencies. The materials for the R&D job were gathered for three months starting from February 2001. Materials from 20 other jobs were also collected three times from the end of May to the end of October 2001. This was done through workshops with professional groups. The highlights of this study are as follows: 1) The results applying the methods developed for drawing out job competencies to the duties of investigation & research part in R&D job were presented as an example. 2) The job competencies of the company totaled 215 in 21 jobs irrespective of overlapping, which means each job has about 10 competencies on the average. 3) The common job competencies of the whole company totaled eight. namely: competency for collecting information/processing/analyzing, communication competency, presentation competency, competency for utilizing the web, competency for planning projects, competency for solving problems, competency for understanding organization/business/products of the company, and competency for satisfying customers.

  • PDF

A Case of Cold Hypersensitivity of Hands and Feet Treated with Korean Medicine Including Gyejifabuja-tang-gmibang and Acupuncture in a Patient with Lumbar Spinal Herniated Intervertebral Disc - A Case Report (한방병원에 입원한 수족냉증을 동반한 추간판탈출증 환자에 대한 한방 치료 1례)

  • Sang-hun Yun;Sang-yoon Kim;Yen-min Wang;Gil-geun Baek;Yu-jin Lee;Hyung-chul Lee;Man-ho Kang;Sung-hwan Park
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.5
    • /
    • pp.1071-1082
    • /
    • 2023
  • Objective: The purpose of this study is to report the efficacy of using Korean medicine treatment with cold hypersensitivity of the hands and feet with lumbar spinal herniated intervertebral disc. Case presentation: We used Korean medicine treatment (Gyejigabuja-tang, acupuncture) to treat a hospitalized patient with cold hypersensitivity of the hands and feet with lumbar spinal herniated intervertebral disc. To evaluate the treatment, we used the Numerical Rating Scale (NRS). The degree of cold hypersensitivity of the hands and feet was also evaluated using evaluation paper. The generic health status was measured using the European Quality of Life-5 Dimensions (EQ-5D) scale. The 31-year-old female underwent 13 days of inpatient treatment. Her pattern identification was that both hands and feet are cold (BiYangHeo) types. The treatments were herbal medicine and acupuncture. She took Gyejigabuja-tang for 13 days. She also received acupuncture for 20 minutes twice a day at LI11 (曲池), L14 (合谷), TE5 (外關) on her hands, LR3 (太衝), SP6 (三陰交), SP9 (陰陵泉) ST36 (足三里), GB41 (足臨泣) on Feet, GV4 (命門), GV3 (腰陽關), BL23 (腎兪), BL24 (氣海兪), BL25 (大腸兪), and BL26 (關元兪) on the low back. After 2 weeks of treatment, the NRS scale of her cold hypersensitivity of hands and feet symptoms dropped from NRS 7 to NRS 3, and her low back pain dropped from NRS 6 to NRS 3. Her cold hypersensitivity of hands and feet evaluation paper score decreased from 64 to 32, and her EQ-5D increased from 0.487 to 0.681. After the end of treatment, continued symptom improvements and no significant side effects were confirmed. Results: These findings suggest that Korean medical treatment (Gyejigabuja-tang, acupuncture) may be effective for treating cold hypersensitivity of hands and feet with lumbar spinal herniated intervertebral disc. The NRS, evaluation paper, and EQ-5D scores improved after treatment, with no side effects.

Limitation of Prediction on Intravenous Immunoglobulin Responsiveness in Kawasaki Disease (가와사끼병에서 정맥용 면역글로불린 치료 반응 예측의 한계)

  • Kim, Seong-Koo;Han, Ji-Yoon;Rhim, Jung Woo;Oh, Jin Hee;Han, Ji-Whan;Lee, Kyung Yil;Kang, Jin-Han;Lee, Joon-Sung
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • Purpose : We aimed to evaluate predictive parameters for non-response to intravenous immunoglobulin (IVIG) in patients with Kawasaki disease (KD) before IVIG use using two controls. Methods : We evaluated 229 consecutive KD patients who were treated with 2 g/kg of IVIG at a single center. Those who had persistent fever >24 hours after IVIG infusion made up the 23 IVIG non-responders; the first control included a total 206 defervesced cases and the second control included 46 cases that were matched for age and pre-treatment fever duration to non-responders. Results : Demographic and clinical characteristics were similar in IVIG non-responders and responders at presentation. As for laboratory findings, the neutrophil differential, CRP, AST, ALT, and LDH were higher, and lymphocyte differential, total protein, albumin, platelet count, and total cholesterol were significantly lower in IVIG non-responders compared to responders by univariate analysis in both study designs. However in multivariate analysis, non-responders showed a significantly higher neutrophil differential (cutoff value, >77%, sensitivity 68.4% and specificity 79.5%) and lower cholesterol (<124 mg/dL, sensitivity 79% and specificity 70.5%). Whereas plasma albumin (<3.6 g/dL, sensitivity 73.7% and specificity 60%) was the sole laboratory parameter of non-responders in the second study design. Conclusion : Severity of inflammation in KD was reflected by higher or lower laboratory values at presentation. Because the multivariate analysis for these indices may be influenced by some confounding factors, including the numbers of patients of different ages and fever duration, other assessment modalities are needed for KD patients with the greatest risk of coronary artery lesions.

Segmentation and 3-Dimensional Reconstruction of Liver using MeVisLab (MeVisLab을 이용한 간 영역 분할 및 3차원 재구성)

  • Shin, Min-Jun;Kim, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1765-1772
    • /
    • 2012
  • Success rate of transplantation of body organs improved due to development of medical equipment and diagnostic technology. In particular, a liver transplant due to liver dysfunction has increased. With the development of image processing and analysis to obtain the volume for liver transplantation have increased the accuracy and efficiency. In this thesis, we try to reconstruct the regions of the liver within three dimensional images using the mevislab tool, which is effective in quick comparison and analysis of various algorithms, and in expedient development of prototypes. Liver is divided by applying threshold values and region growing method to the original image, and by removing noise and unnecessary entities through morphology and region filling, and setting of areas of interest. It is deemed that high temporal efficiency, and presentation of diverse range of comparison and analysis module application methods through usage of MeVisLab would make contribution towards expanding of baseline of medical image processing researches.

3-D Shock Structure of Orion KL Outflow with IGRINS

  • Oh, Heeyoung;Pyo, Tae-Soo;Kaplan, Kyle F.;Koo, Bon-Chul;Yuk, In-Soo;Lee, Jae-Joon;Mace, Gregory N.;Sokal, Kimberly R.;Hwang, Narae;Park, Chan;Park, Byeong-Gon;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.38.3-38.3
    • /
    • 2018
  • We present the results of high-resolution near-IR spectral mapping toward the Orion KL outflow. In this study, we used the Immersion Grating Infrared Spectrometer (IGRINS) on the 2.7 m Harlan J. Smith Telescope at McDonald Observatory. IGRINS's large wavelength coverage over the H & K bands and high spectral resolving power (R ~ 45,000) allowed us to detect over 35 shock-excited ro-vibrational H2 transitions and to measure directly the gas temperature and velocity of the dense outflows. In our previous study toward the H2 peak 1 region in the Orion KL outflow, we identified 31 outflow fingers from a datacube of the H2 1-0 S(1) $2.122{\mu}m$ line and constructed a three-dimensional map of the fingers. The internal extinction (${\Delta}AV$ > 10 mag) and overall angular spread of the flow argue for an ambient medium with a high density (105 cm-3). In this presentation, we show preliminary results of additional mapping toward a remarkable chain of bows (HH 205 - HH 207) farther from the ejection center, and obtain a more clear view of the shock physics of a single isolated bullet that improves on the knowledge gained from observations of the more complex peak 1 region in our earlier study.

  • PDF

Presentation of Neurolytic Effect of 10% Lidocaine after Perineural Ultrasound Guided Injection of a Canine Sciatic Nerve: A Pilot Study

  • Kim, David D;Asif, Asma;Kataria, Sandeep
    • The Korean Journal of Pain
    • /
    • v.29 no.3
    • /
    • pp.158-163
    • /
    • 2016
  • Background: Phenol and alcohol have been used to ablate nerves to treat pain but are not specific for nerves and can damage surrounding soft tissue. Lidocaine at concentrations > 8% injected intrathecal in the animal model has been shown to be neurotoxic. Tests the hypothesis that 10% lidocaine is neurolytic after a peri-neural blockade in an ex vivo experiment on the canine sciatic nerve. Methods: Under ultrasound, one canine sciatic nerve was injected peri-neurally with 10 cc saline and another with 10 cc of 10% lidocaine. After 20 minutes, the sciatic nerve was dissected with gross inspection. A 3 cm segment was excised and preserved in 10% buffered formalin fixative solution. Both samples underwent progressive dehydration and infusion of paraffin after which they were placed on paraffin blocks. The sections were cut at $4{\mu}m$ and stained with hemoxylin and eosin. Microscopic review was performed by a pathologist from Henry Ford Hospital who was blinded to which experimental group each sample was in. Results: The lidocaine injected nerve demonstrated loss of gross architecture on visual inspection while the saline injected nerve did not. No gross changes were seen in the surrounding soft tissue seen in either group. The lidocaine injected sample showed basophilic degeneration with marked cytoplasmic vacuolation in the nerve fibers with separation of individual fibers and endoneurial edema. The saline injected sample showed normal neural tissue. Conclusions: Ten percent lidocaine causes rapid neurolytic changes with ultrasound guided peri-neural injection. The study was limited by only a single nerve being tested with acute exposure.

Piezoelectric and electromechanical properties of PZT films and PZT microcantilever (PZT 박막의 압전 특성 및 MEMS 기술로 제작된 PZT cantilever의 전기기계적 물성 평가)

  • 이정훈;황교선;윤기현;김태송
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.177-180
    • /
    • 2002
  • Thickness dependence of crystallographic orientation of diol based sol-gel derived PZT(52/48) films on dielectric and piezoelectric properties was investigated The thickness of each layer by one time spinning was about 0.2 $\mu\textrm{m}$, and crack-free films was successfully deposited on 4 inches Pt/Ti/SiO$_2$/Si substrates by 0.5 mol solutions in the range from 0.2 $\mu\textrm{m}$ to 3.8 $\mu\textrm{m}$. Excellent P-E hysteresis curves were achieved without pores or any defects between interlayers. As the thickness increased , the (111) preferred orientation disappeared from 1$\mu\textrm{m}$ to 3 $\mu\textrm{m}$ region, and the orientation of films became random above 3 $\mu\textrm{m}$. Dielectric constants and longitudinal piezoelectric coefficient d$\_$33/, measured by pneumatic method were saturated around the value of about 1400 and 300 pC/N respectively above the thickness of 0.8 7m. A micromachined piezoelectric cantilever have been fabricated using 0.8 $\mu\textrm{m}$ thickness PZT (52/48) films. PZT films were prepared on Si/SiN$\_$x/SiO$_2$/Ta/Pt substrate and fabricated unimorph cantilever consist of a 0.8 fm thick PZT layer on a SiNx elastic supporting layer, which becomes vibration when ac voltage is applied to the piezoelectric layer. The dielectric constant (at 100 kHz) and remanent polarization of PZT films were 1050 and 25 ${\mu}$C/$\textrm{cm}^2$, respectively. Electromechanical characteristics of the micromachined PZT cantilever in air with 200-600 $\mu\textrm{m}$ lengths are discussed in this presentation.

  • PDF