• Title/Summary/Keyword: 360도

Search Result 448, Processing Time 0.03 seconds

국내 박쥐에서의 일본뇌염 바이러스 항체 조사

  • 이재상;이연태
    • Korean Journal of Microbiology
    • /
    • v.30 no.2
    • /
    • pp.115-123
    • /
    • 1992
  • A total of453 wilci hats inhabiting in Korea were captured ancl .he IgG antibodies againstJapanese Encephalitis Virus(J1IV) were detected by the heniagglut:nation inhibition te5t. 35501' the 453 blood sera showecl positive reaction to JEV with titers of I0 up to 40. Positiverates of male and kniale hats were 70.0'%1 anel 78.1'k. rcspectivclv. Positive ratci accordingto area were 74.7%) in Chungnan~. 72.h'\ulcorner6 in Kangwon and 74.3'"; in C'hungbuk. the resultbof which indicated no dil'krencc in areii. Whereas positive ratus according to hats specie5were 87.5(% f i ~ rC i..cpc~rtilios upernns. fi~llowedb y 83 3'%, k)r Mpoii.\ i ~ ~ : t r u ~ i tci.i~lis~. ~75l.0. '\4 1 forRhitrolol~h.\ '||'&'||',rurn~uic,r~unal ncl 59.6'!41 for Minioprc,ru.s schrc~ibersii.I t was Ibund by incli rrctini~nunofluorosce~icae nd clectron microscope techniques that the virus particles 01. JEVcould infect the brain of a Korean wilcl bats and proliferatn ill the brain cells.he brain cells.

  • PDF

IMPROVING METHOD FOR VERIFYING STEERING ANGLE SIGNAL OF EPS (차량용 EPS의 조향각 신뢰성 향상 제안)

  • Jang, Hyunseop;Kwon, Dowook;Han, Sangwhi
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1507-1510
    • /
    • 2012
  • 본 논문은 EPS(전자식 파워 스티어링)에 사용되는 Torque and Angle sensor 의 절대각 신뢰성 보증 방식에 관한 것으로, Inductive 방식의 센서에서 절대각 신호 신뢰성 보증에 대한 효과적인 방법을 제시한다. 전동식 파워 스티어링 시스템의 ECU(전자제어유닛)는 조타각도를 출력하는 2 개의 소자에서 버니어 알고리즘을 통해 360 도 이상의 멀티 조타각을 인식하게 된다. 토크&조향각 센서는 절대 조향각을 계산하는 1 개의 Hall IC 소자 신호와, 상대 조향각을 계산하는 ASIC 소자 신호를 사용하여 멀티 조타각을 인식한다. 인식된 조타각이 추가적인 검증 절차 없이 제어에 사용된다면, 센서의 이상 발생 시에 운전자의 조타감을 불편해질 수 있고, 나아가서는 차량사고의 위험을 발생시킬 수 있다.따라서 차량 거동 시 절대 조향각의 신뢰성 검증은 제어와 동시에 항상 요구되어야 한다. 특히, 유럽/미국 업계의 ISO 26262 표준 도입에 따라 절대 조향각의 높은 신뢰성이 요구된다. 본 논문에서는 이러한 요구사항을 만족하기 위해 측정된 절대각 신호를 기준으로 상대각 신호 2 개를 측정에 사용하고, Driving 시에도 절대각 기준의 신뢰도 향상을 위해 절대각 신호 1 개를 비교기로 사용한다. 최적화된 에러 기준을 근거로 절대 조향각 신호의 신뢰성을 보장하는 방법을 제안한다. 이러한 방법을 적용한다면, 정확하고 안정적으로 조타각을 결정함으로써 EPS 안전성 확보에 도움을 줄 수 있다.

Browning and Pungent Taste Reduction Techniques in Onion Extract (양파추출물의 갈변 및 매운맛 억제기술)

  • Kim, Hee Sun;Kim, Myung Hwan
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.360-364
    • /
    • 2009
  • The onion extractions of MIX treatment (5% $\beta$ cyclodextrin+1% calcium chloride+1% soluble starch mixture solution) using hot water (100${^{\circ}C}$ and 80${^{\circ}C}$) and ultrasonic treatment (25${^{\circ}C}$) incresed L values and decreased a and b values apart from the extraction methods. Extent of the browning reaction as caused by the MIX treatment (0.093) following 100${^{\circ}C}$ water extraction resulted in as low as 31% O.D. level, as compared to the control(0.296). Analysis of the pyruvic acid showed that the control had higher content of pyruric acid than MIX-treated samples. The MIX treatment had lower intensities and higher preferences of browning color and pungency taste compared to the control. The total and coliform microbial counts increased continuously during storage period, while the MIX treatment reduced the number of viable cells. Finally, it was concluded that the MIX treatment was highly effective in suppressing the undesirable browning color and pungent taste after processing, and the microbes increment during storage.

Interactive Cultural Content Using Finger Motion and HMD VR (Finger Motion과 HMD VR을 이용한 인터렉티브 문화재 콘텐츠)

  • Lee, Byungseok;Jung, Jonghee;Back, Chanyeol;Son, Youngro;Chin, Seongah
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.11
    • /
    • pp.519-528
    • /
    • 2016
  • Most cultural contents currently we face are not suitable for associating with state of arts and high technology as simply providing one-sided learning. Pictures and movies of cultural contents also sees to utilize for efficacy of cultural education. There are still some limitations to draw interest from users when providing one-sided learning for cultural study, which aims to only deliver knowledge itself. In this paper, we propose interactive HMD VR cultural contents that can support more experience to get rid of aforementioned limitations. To this end, we first select quite interesting and wellknown cultural contents from world wide to draw more attention and effect. To increase immersion, presence and interactivity we have used HMD VR and Leapmotion, which intentionally draws more attention to increase interest. The cultural contents also facilitate augmented information as well as puzzle gaming components. To verify, we have carried out a user study as well.

Researching for Improvement Directions for Elementary school Real-time Remote Learning Through Unit Class Analysis and Teacher Interviews (단위 차시 수업 분석 및 교사 면담을 통한 초등학교 실시간 원격수업 개선 방향 모색)

  • Kim, Dong-jin;Koo, Duk-hoi
    • 한국정보교육학회:학술대회논문집
    • /
    • 2021.08a
    • /
    • pp.355-360
    • /
    • 2021
  • COVID-19 has brought major changes to school education. Although it was attempted to guarantee students' right to learn through romote learning, the limitations of remote learning compared to face-to-face classes were clear. Nevertheless, the method of remote learning is undoubtedly a learning method that needs to be continuously developed in terms of being able to consider separated time and space and enabling learners to learn individually and autonomously. Therefore, in this study, real-time romote learning cases were analyzed at the elementary school stage, and problems in real-time remote classes were discovered and improved through teacher interviews. The problems with real-time remote classes in elementary school unit classes examined through examples are: First, that the proportion of teacher activity is high due to the anxiety of the unfamiliar environment of remote classes, and second, even though it is a real-time interactive class, it It was impossible to provide feedback. As a solution to this, it is necessary to consider the basic class steps (introduction-deployment-organization) and the use of class tools to provide appropriate communication and feedback was suggested.

  • PDF

Synthesis and characterization of Pb10-xCux(PO4)6O polycrystalline samples

  • Huiwon Kim;Minsik Kong;Minjae Kim;Seohee Kim;Jong Mok Ok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.5-9
    • /
    • 2023
  • Lee, Kim, et al. reported in July 2023 that a modified lead apatite material, Pb10-xCux(PO4)6O (0.9 < x < 1.1), exhibited superconductivity at room temperature and atmospheric pressure [1, 2]. However, their X-ray diffraction data clearly showed the presence of impurity phases, including Cu2S, raising uncertainty about the sample quality. Subsequent studies have been conducted; however, different samples exhibited various physical properties. To verify the recipe for the sample growth process, we synthesized samples following the methodology outlined in the reference [1, 2]. An analysis of the structure and physical properties of the synthesized sample reaffirms the critical importance of high-quality sample growth.

A Road Traffic Noise Management Using a Noise Mapping Simulation (소음지도 시뮬레이션을 이용한 도로교통소음 개선방안 연구)

  • Kim, Hyung-Chul;Jeong, Jea-Hun;Kwon, Woo-Taeg
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.353-360
    • /
    • 2007
  • Rapid urbanization and population increasing are making a high-rise residential building and high-density residential area. According to spacial concentration of population is occurred road traffic noise problem. Now we are popularly using almost only noise barrier installation, but it makes many disfunctions such as poor landscape, low noise barrier performance and crimes. The purpose of this research is to figure out which is best method one the traffic noise management. Alternative are composed to building layout type ($30^{\circ},\;90^{\circ},\;180^{\circ}$), separation between road and residential building, noise barrier types(noise barrier only, noise barrier and forests and etc). The noise barrier are shown to reduce barrier and building layout angle $30^{\circ}$ position is the best comparing with horizontal and vertical layouts. The gab distance is decreased approximately noise level 5dB(A). We figured out there are noise important method except noise barrier wall and it was analyzed how much decreased. This can be very useful before making a road planning and residential building design.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Design of CMOS Multifunction ICs for X-band Phased Array Systems (CMOS 공정 기반의 X-대역 위상 배열 시스템용 다기능 집적 회로 설계)

  • Ku, Bon-Hyun;Hong, Song-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.6-13
    • /
    • 2009
  • For X-band phased array systems, a power amplifier, a 6-bit phase shifter, a 6-bit digital attenuator, and a SPDT transmit/receive (T/R) switch are fabricated and measured. All circuits are demonstrated by using CMOS 0.18 um technology. The power amplifier has 2-stage differential and cascade structures. It provides 1-dB gain-compressed output power ($P_{1dB}$) of 20 dBm and power-added-efficiency (PAE) of 19 % at 8-11 GHz frequencies. The 6-bit phase shifter utilizes embedded switched filter structure which consists of nMOS transistors as a switch and meandered microstrip lines for desired inductances. It has $360^{\circ}$ phase-control range and $5.6^{\circ}$ phase resolution. At 8-11 GHz frequencies, it has RMS phase and amplitude errors are below $5^{\circ}$ and 0.8 dB, and insertion loss of $-15.7\;{\pm}\;1,1\;dB$. The 6-bit digital attenuator is comprised of embedded switched Pi-and T-type attenuators resistive networks and nMOS switches and employes compensation circuits for low insertion phase variation. It has max. attenuation of 31.5 dB and 0.5 dB amplitude resolution. Its RMS amplitude and phase errors are below 0.4 dB and $2^{\circ}$ at 8-11 GHz frequencies, and insertion loss is $-10.5\;{\pm}\;0.8\;dB$. The SPDT T/R switch has series and shunt transistor pairs on transmit and receive path, and only one inductance to reduce chip area. It shows insertion loss of -1.5 dB, return loss below -15 dB, and isolation about -30 dB. The fabricated chip areas are $1.28\;mm^2$, $1.9mm^2$, $0.34\;mm^2$, $0.02mm^2$, respectively.