• Title/Summary/Keyword: 3-in-1 flowable composite

Search Result 66, Processing Time 0.029 seconds

Stress distribution of Class V composite resin restorations: A three-dimensional finite element study (5급 복합레진수복물의 응력분포에 관한 3차원 유한요소법적 연구)

  • Park, Jeong-Kil;Hur, Bock;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.28-38
    • /
    • 2008
  • This study was to investigate the influence of composite resins with different elastic modulus, cavity modification and occlusal loading condition on the stress distribution of restored notch-shaped noncarious cervical lesion using 3-dimensional (3D) finite element (FE) analysis. The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. A notch-shaped cavity and a modified cavity with a rounded apex were modeled. Unmodified and modified cavities were filled with hybrid or flowable resin. After restoration, a static load of 500N was applied in a point-load condition at buccal cusp and palatal cusp. The stress data were analyzed using analysis of principal stress. The results were as follows: 1. In the unrestored cavity, the stresses were highly concentrated at mesial CEJ and lesion apex and the peak stress was observed at the mesial point angle under both loading conditions. 2. After restoration of the cavity, stresses were significantly reduced at the lesion apex, however cervical cavosurface margin, stresses were more increased than before restoration under both loading conditions. 3. When restoring the notch-shaped lesion, material with high elastic modulus worked well at the lesion apex and material with low elastic modulus worked well at the cervical cavosurface margin. 4. Cavity modification the rounding apex did not reduce compressive stress, but tensile stress was reduced.

A NEW METHOD TO MEASURE THE LINEAR POLYMERIZATION SHRINKAGE OF COMPOSITES USING A PARTICLE TRACKING METHOD WITH COMPUTER VISION (컴퓨터 시각과 입자 추적 방법을 이용한 복합레진의 선형중합수축 측정의 새로운 방법)

  • Lee, In-Bog;Min, Sun-Hong;Seo, Deog-Gyu;Kim, Sun-Young;Kwon, Young-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Since the introduction of restorative dental composites, their physical properties have been significantly improved. However, polymerization shrinkage is still a major drawback. Many efforts have been made to develop a low shrinking composite, and silorane-based composites have recently been introduced into the market. In addition, many different methods have been developed to measure the polymerization shrinkage. In this study, we developed a new method to measure the linear polymerization shrinkage of composites without direct contact to a specimen using a particle tracking method with computer vision. The shrinkage kinetics of a commercial silorane-based composite (P90) and two conventional methacrylate-based composites (Z250 and Z350) were investigated and compared. The results were as follows: 1. The linear shrinkage of composites was 0.33-1.41%. Shrinkage was lowest for the silorane-based (P90) composite, and highest for the flowable Z350 composite. 2. The new instrument was able to measure the true linear shrinkage of composites in real time without sensitivity to the specimen preparation and geometry.

Evaluation of Flexural Properties of Indirect Gum-Shade Composite Resin for Esthetic Improvement (심미성 향상을 위한 간접수복용 Gum-Shade 복합레진의 굽힘 특성 평가)

  • Im, Yong-Woon;Hwang, Seong-Sig
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.407-412
    • /
    • 2015
  • This study investigated flexural properties of indirect Gum-shade composite resins for esthetic improvement. The material utilized in this study was Crea.lign, Twiny flow and Twiny paste (TP). Ten specimens were fabricated with a dimension of $25{\times}2{\times}2mm$ according to the ISO 4049. After fabrications, specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending test was performed in universal testing machine (Instron 3344; Instron, USA) at a crosshead speed of 1 mm/min until the failure occurred. TP exhibited a higher flexural strength (FS) and flexural modulus (FM) compared to the flowable materials. There were significant differences among the three materials in FS and FM. However, there was no significant difference in work of fracture (WOF) in all tested materials (p>0.05). In Weibull analysis, TP showed the greatest Weibull modulus which means a higher reliability of the materials. Also, Gum-shade composite resins revealed a strong correlation in all flexural properties. There was a positive correlation in FS-FM ($r^2=0.99$) and a negative correlation between FS-WOF and FM-WOF ($r^2>0.97$). Therefore, this confirmed that flexural property was important for mechanical behavior evaluation and useful information. To addition, this improved among mechanical properties correlation of materials as important factor.

EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN (수종의 이장재가 복합레진의 중합수축에 미치는 영향)

  • Choi, Ji-Won;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.606-614
    • /
    • 2006
  • The purpose of this study was to evaluate the polymerization contraction of composite resin(Tetric $ceram^{(R)}$, Ivoclar Vivadent Liechtenstein) according to various liners(Tetric $flow^{(R)}$, Ivoclar Vivadent, Liechtenstein/$Ionosit^{(R)}$, DMG, German/ $Vitrebond,^{TM}$ 3M-ESPE, USA). The strain gauge method was used for measurement of polymerization shrinkage strain. Specimens were divided by 8 groups according to curing units and liners. Group A, E: Tetric $ceram^{(R)}$ bulk filing, Group B, F: Tetric $flow^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group C, G: $Ionosit^{(R)}$ lining, Tetric $ceram^{(R)}$ filling, Group D, H: $Vitrebond^{TM}$ lining, Tetric $ceram^{(R)}$ filling. Group A, B, C and D were cured using the conventional halogen light($XL3000^{TM}$ 3M ESPE, USA) for 40 seconds at $400mW/cm^2$. Group E, F G and H were cured using light emitted diode(LED) light(Elipar Freelight $2^{TM}$, 3M-ESPE, USA) for 15 seconds at 800 $mW/cm^2$. Strain gauge attached to each sample was connected to a strainmeter. Measurements were recorded at each second for the total of 750 seconds including the periods of light application. Obtained data were analyzed statistically using Repeated measures ANOVA and Tukey test. The results of this were as follows : 1. Contraction stresses in flowable resin and glass ionomer lining group were lower than that in compomer lining group(p<0.05). 2, Contraction stresses in LED curing light groups were higher than that in halogen curing light groups, but there was no significant difference (p>0.05).

  • PDF

EFFECT OF STEP CURING ON THE CONTRACTION STRESS AND MARGINAL ADAPTATION OF RESIN RESTORATION (단계별 광중합 방식이 복합레진 수복물의 수축 응력과 변연 접합도에 미치는 영향)

  • Park, Jong-Whi;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.221-232
    • /
    • 2006
  • The purpose of this study was to investigate the effect of step-curing mode on polymerization shrinkage and contraction of composite resin restoration. Class I cavities were prepared on the extracted human premolars. The cavities were ailed with Filtek $Z-250^{TM}$ (hybrid resin, 3M ESPE, USA) and Filtek $flow^{TM}$ (flowable resin, 3M ESPE, USA) and cured with one of the following irradiation modes; Halogen 40sec with continuous curing, LED 10sec with continuous curing, and LED 13sec with step-curing. Contraction stress was measured with strain gauge which was connected to TML $Datalogger^{TM}$ (TDS-102, SOKKI, Japan) and resin-dentin interfaces were observed by scanning electron microscope. The results of present study can be summarized as follows : 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05) 2. $Filtek\;flow^{TM}$ showed lower contraction stress than Filtek $Z-250^{TM}$ regardless of curing modes. 3. LED step-curing mode showed lowest contraction stress in Filtek $Z-250^{TM}$ compared with other curing modes(P<0.05). 4. LED step-curing mode showed lowest contraction stress in $Filtek\;flow^{TM}$ compared with other curing modes(P<0.05), but difference in contraction stress was not so greate as in $Filtek\;Z-250^{TM}$. 5. Polymerization of composite resin by LED light with step-curing mode and halogen light with continuous ode resulted in better marginal sealing than LED light with continuous mode.

  • PDF

Bond strength of fiber reinforced composite after repair (섬유 강화 컴포지트의 수리 후 접합 강도)

  • Kim, Min-Jung;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.188-197
    • /
    • 2006
  • Fiber reinforced composite (FRC) is usually used as a connector joining a few teeth into one unit in orthodontics. However, fracture often occurs during the two to three years of the orthodontic treatment period due to repeated occlusal loading or water sorption in the oral environment. We simulated the repair by overlapping and attaching portions of two FRC strips in the middle and performed a three-point bending test to investigate the changes of the repair strength among the different FRC groups. The specimens were grouped according to the overlapping lengths of the two FRC strips, which were 1, 2, 3 and 4 mm (group E1, E2, E3 and E4, respectively) and the control group consisted of unrepaired, intact FRC strips. Each group consisted of 6 specimens and were cured with a light emitting diode curing unit. Group E4 showed the highest maximum loads of 2.67 N, then the control group (2.39 N), group E3 (2.35 N), E2 (2.10 N), and E1 (1.75 N) in decreasing order. Group E4 also showed the highest stiffness, which was 2.32 N/mm, however, the stiffness of group E3 (2.06N/mm) was higher than that of the control group (1.88 N/mm). According to the visual examination, the specimens tended to be bent rather than being fractured into two pieces with an increased length of overlapping portions. The above results suggest that a minimum overlapping length of 3 mm was necessary to obtain an adequate repair of a 10 mm length of FRC connector. In addition, the critical section adjacent to the joint area, where the thickness decreased abruptly, should be reinforced with flowable resin to minimize the bending tendency.

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH (강화형 strip crown의 사용)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.132-135
    • /
    • 2005
  • The purpose of this study was to propose the modified strip crown technique for esthetic restoration of primary anterior teeth using glass fibers. Celluloid crown form(3M, USA), Z100(P shade, 3M, USA). Aeliteflo(Bisco Inc., USA), and Clearfil SE Bond(Kuraray Medical Inc., Japan) were used for this technique. Mesh type of glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA) was used for reinforcing material. After trimming the celluloid crown form, resin adhesive and flowable resin were applied on the pre-shaped glass fiber mesh. That mesh was placed on the lingual surface of inside of celluloid crown form and followed by light activation. Composite resin was filled into the celluloid crown form and put it on a prepared tooth and then light activated and finished the margin. The new modified strip crown technique can provide esthetics and increased durability for restoration of primary anterior teeth.

  • PDF

COMPARISON OF MARGINAL LEAKAGE OF WEDGE-SHAPED CLASS V CAVITY ACCORDING TO RESTORATIVE MATERIALS (쐐기 형태의 5급와동에서 수복재료에 따른 변연 미세누출의 비교)

  • Jang, Hyun-Joo;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2000
  • The purpose of this study was to assess the effects of restorative materials on the marginal leakage of wedge-shaped class V cavity. The study was performed in vitro in 25 defect-free permanent, extracted teeth. Wedge-shaped class V cavities were prepared and then the teeth were randomly selected and restored according to the following. Group A : restoration with Tetric Ceram(composite resin) Group B : restoration with Tetric flow(flowable resin) Group C : restoration with Compoglass after acid etching(compomer) Group D : restoration with Compoglass(compomer) Group E : restoration with Fuji II LC improved(resin-modified GIC) After thermocycling, the specimens were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally through the center of the restoration. The degree of marginal leakage was measured as the extent of dye penetration under the stereomicroscope. The data were analysed using one-way ANOVA. When significant differences found, multiple comparisons were made using Duncan's Multiple Range Test. The results were as follows: 1. The occlusal margins of all groups except for Fuji II LC improved showed lesser leakage than gingival margins and there was statistically significant difference(p<0.05). 2. At the occlusal margins, group A, B showed same marginal leakage scores, and others were decreased as group C, D, E in that order. There were statistically significant difference between group A, Band group D, E, group C and group E(p<0.05). 3. At the gingival margins, group B, C showed same marginal leakage scores, and others were decreased as group A, D, E in that order. But there was statistically significant difference between group B, C and group E(p<0.05). 4. In the Compoglass restoration, acid-etching technique was beneficial for marginal sealing ability at all of margins. But there was no statistically significant difference (p>0.05). In the restorations for wedge-shaped class V cavities, resin restoration with acid etching technique is recommended.

  • PDF

Effects of thickness and background on the masking ability of high-trasnlucent zirconias (고투명도 지르코니아의 두께 및 하부 배경에 따른 색조 차단 효과)

  • Kim, Young-Gon;Jung, Ji-Hye;Kong, Hyun-Jun;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Purpose: The purpose of this study was to compare and evaluate the masking ability of three types of high translucent zirconia according to the various thicknesses and backgrounds. Materials and Methods: Using three types of high-translucency zirconia (Ceramill zolid fx white, Ceramill zolid ht+ white, Ceramill zolid ht+ preshade A2), 10 cylindrical specimens were fabricated in 10mm diameter and each with four thicknesses (0.6 mm, 1.0 mm, 1.5 mm, 2.0 mm), respectively by CAD/CAM method. The background was 10 mm in diameter and 10 mm in thickness. A1, A2, A3 flowable resin backgrounds, blue-colored core resin background, and Ni-Cr alloy background were prepared, and black, white backgrounds provided by the spectrophotometer manufacturer (x-rite, Koblach, Austria) were used. zirconia specimens and the background specimen were stacked to measure L, a*, b* with Spectrophotometer (Color i5, x-rite, Koblach, Austria) and the ΔE value with the other background is calculated. The Calculated mean ΔE values were compared based on perceptibility threshold 1.0 and acceptability threshold 3.7. Nonparametric tests such as Kruskal-Wallis test were performed to verify statistical significance (α = 0.05). Results: There was a significant difference in the mean ΔE value according to the zirconia type, background and thickness change (P = 0.000). Conclusion: According to the results of this study, the pre-colored high-translucent zirconia can obtain the desired zirconia shade when it is restored on teeth, composite resins, and abutments except for the blue resin core.