• Title/Summary/Keyword: 3-arm type

Search Result 259, Processing Time 0.025 seconds

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.

Coma Aberration Correction of Optical System by using a Robot Arm Type Coordinated Measuring Machine (로봇팔 타입 삼차원좌표측정기를 이용한 광학계의 비축수차 보정)

  • Chun, Ho Bin;Kim, Goeun;Song, In-Woong;Kang, Hyug-Mo;Rhee, Hyug-Gyo;Ghim, Young-Sik;Yang, Ho-Soon;Kwon, Jong Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.62-66
    • /
    • 2016
  • Optical system needs to be aligned before its undergoing process, is usually shows coma aberrations, which occurred due to imperfection in the lens or other components results in off-axis point sources, appearing to have a tail like a comet. There are some methods to correct coma aberration. In this paper, to correct coma aberration in optical system, using a robot arm type coordinate measuring machine(CMM). CMMs are widely used to measure the form of accuracy of parts and positioning accuracy of systems. Among them, robot arm type CMM has more advantages than the others, such as its mobility and measuring range. However, robot arm type CMM has lower accuracy than cantilever type CMM. To prove robot arm type CMM's accuracy, several factors were suggested in this paper and the final measuring results were compared to a commercial cantilever type CMM. Based on this accuracy, a typical optical system was successfully aligned by using our robot arm type CMM.

Design of a Torque Arm Pin and Elastomeric Bushings for the Three-point-Suspension Gearbox of a Wind Turbine (풍력발전기용 3점 지지 기어박스의 토크암 핀 및 탄성중합체 부싱 설계)

  • Shim, Sung Bo;Nam, Ju Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.199-204
    • /
    • 2017
  • In this study, analytical methods for designing a torque arm pin and elastomeric bushings of a conventional-type three-point-suspension gearbox of a wind turbine are investigated. The design loads for the torque arm were derived by considering the effects of the transmitted torque and self-weight of the gearbox. Based on the design loads, design methods for the torque arm pin and elastomeric bushings were introduced in the terms of material and size selection. Finally, a small-scale conventional-type gearbox was designed by applying the derived design methods. This study is an elementary and analytical study for the design of the torque arm pin and elastomeric bushings. It is necessary to verify and supplement the results further through extensive experimentation.

A Study on the Mechanism of Arm Surface Changes for the development of Sleeve Drafting Standard (소매설계기준 개발을 위한 상지체표변화구조에 관한 연구)

  • 최해주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.5
    • /
    • pp.852-859
    • /
    • 1996
  • The factors and mechanism of arm surface changes were analyzed by regression analysis for the relationship between changes in arm joint angle and arm surface changes, according to the direction of upper extremity motion. Body surface change patterns among subjects were tested also. Experiments were carried out on 3 female subjects of different body types to examine 26 motions in 4 directions for 4 upper extremity parts. The major conclusions of the study are as follows: 1. The expansion or contraction of arm surface length depends on the direction of upper extremity motion. 2. Arm surface length changes by linear expansion or contraction according to the joint angle of the direction of motion. The mechanism of arm surface changes is represented by a linear relation between arm surface changes and the (actors of the direction of upper extremity motion and arm joint angle. 3. Arm surface length shows the same pattern of body surface changes regardless of body type. A quantitative model of body surface changes at upper extremity should be developed for functional sleeve design.

  • PDF

Analysis of Kinematic Parameters of Gait in Normal Subject (정상 성인의 운동 형상학적 보행 분석)

  • Jung, Hwa-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2989-2995
    • /
    • 2014
  • This study was to performed to get the reference data of the kinematic parameters for normal subjects according to the arm movement type. Forty-five normal subjects participated in this study and preformed four sequence according to the arm movement type : normal arm movement, one arm movement, no arm movement, fitness arm movement. The study data was collected from June to August 2010. The kinematic data were measured using Vicon motion system 6MX3 cameras while each subjects walked through a 10m walkway. There were significant differences according arm movement type in the kinematic parameters such as range of motion (ROM) of the right pelvic, hip in sagittal plane, and ROM of the pelvic, hip, lumbar in coronal plane and ROM of the pelvic, thoracic, lumbar in transverse plane. This study can be utilized as the basic reference data in gait analysis for patients with pathologic gaits.

A Study on Classification of Bodytype of Elderly Males for Upper Garments Construction (상의 구성을 위한 노년기 남성의 체형 분류)

  • 이선명
    • The Research Journal of the Costume Culture
    • /
    • v.1 no.2
    • /
    • pp.159-179
    • /
    • 1993
  • The purpose of this study is to collect data for he improvement of the accuracy of upper garments construction of the old whose bodies have been changed due to their age. In this study the body measurements with 61 items were taken from 226 men(aged fro m 60 to 80) living in Seoul by the R. Martin's method in 1992. The data were calculate by computer and analyzed by the multivariate method, especially factor and cluster analysis. The results of the study were as follows; 1. The average stature of elderly males was 163.6cm, chest circumference 91.6cm, waist circumference 9\\85.5cm. hip circumference 92.8cm, neck circumference 37cm, arm length 55.4 cm, back length 42.6cm, shoulder breadth 42.9cm and the Roher's Index 1.39, which was a standard body shape. 2. The items of factor analysis were explained to seven, namely, the degree of fatness of the upper body, the size of the frame of body, the length of the upper body, the degree of curve of the front body, the size of shoulder, the shape of the back, and the slope of shoulder. 3. The body types of subjects were classified into four types. The majority was type 4, which was 67% of subjects and considered as balanced body type. The distinctive features of those types are as follows; Type 1. The subjects of this type had a slight skeletal structure and were the thinnest of all the subjects with thin and forward-bent arm. Type 2. The subjects of this type were the tallest of all the subjects. they had the straightest side of body and a well-developed upper arm. The thigh length of this type was longer than the length of trunk. Type. 3. The subjects of this type was only one, so ti could be excluded. Type 4. The subjects of this type had a long trunk, well-developed shoulder, and a crook in their neck and back. The arm length and thigh of this type were short and those circumferences were thick. Type 5. The subjects of this type were the shortest of all, but had the highest degree of fatness in the waist and abdominal. They had well-developed front muscles of body and projected hip.

  • PDF

Classifications of Arm and Correspondence with Partial Somatotype of Upper Body (팔의 유형화와 상반신 부분체형과의 대응에 관한 연구)

  • 이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.864-875
    • /
    • 1999
  • This study was done to classify type os arms and to correspond these types with partial somatotype of upper body such as lateral views of upper body shapes of shoulder. The subjects of this study were female college students of twenties 58 anthropometric and photographic data were measured. The results were as follows : 1. Form the factor analysis arm girth/armscye size factor arm length factor the slope of lower arm, arm factor the curves of armscye the roundness of arm/shapes of shoulder the slope of upper arm factor were obtained. 2. By using factor scores 4 clusters of arm types were extracted. The characteristics of these clusters were projections of armscy slant of lower arm thick-set canelike. 3. Four types of arm were corresponded with the specified lateral views of upper body directions of shoulder slopes of shoulder.

  • PDF

Structural design of small form factor swing arm type actuators with thermal stability (열안정성을 고려한 초소형 정보저장기기용 액추에이터 구조설계)

  • Park, Chul;Yoo, Jeong-Hoon;Park, No-Cheol;Park, Young-Pil;Shimano, Takeshi;Nakamura, Shigeo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.208-213
    • /
    • 2006
  • The present state of the design of swing arm actuators for optical disc drives is to obtain the high efficient dynamic characteristics within a very compact volume. As a necessary consequence, the need of the small form factor (SFF) storage device has been arisen as major interests in the information storage technology. In this paper, we suggest the miniaturized swing arm type actuator that has high efficient dynamic characteristics for SFF optical disk drive (ODD). For the operating mechanism, it uses a tracking electromagnetic (EM) circuit for a focusing motion together. Moreover, due to the size constraint, the thermal stability of optical head is important. Therefore, the actuator is designed to emit the heat, which is generated by optical pick-up, along the actuator body easily. Initial model is designed based on the topology optimization method considering the thermal conductivity. Then, the structural parts of the actuator are modified to maintain the high sensitivity and to have wide control bandwidth by the design of experiments method (DOE) and new concept of decreasing mass and inertia. Finally, a swing arm type actuator for SFF ODD is suggested and its dynamic characteristics are verified.

  • PDF

Door Effort Analysis for Door Checker of Integrated Type with Torsion Bar Spring (토션 바 스프링을 적용한 일체형 도어체커 개폐력 해석)

  • Yoon, Sang-Min;Kang, Sung-Jong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.86-91
    • /
    • 2012
  • Door effort was calculated for a new door checker with torsion bar spring and integrated checker case by FE analysis. A hybrid checker arm which has peaks and valleys only on the upper surface was adopted to reduce noise in operation and make operation with more distinctive steps. The checker arm was modeled using shell elements to estimate both the longitudinal and the lateral resistance force by checker arm. By combining the checker arm resistance force obtained from analysis and the door self-closing force by the theoretical calculation, door effort was predicted to show the good correlation with test results. In addition the unrolling effect of roller model was investigated and a new roller type for more smooth rolling was studied.

Optimal Location of Support Point for Weight Minimization in Radial Gate of Dam Structures (회전식 수문의 중량 최소화에 대한 지지점 위치의 최적설계)

  • Kwon, Young-Doo;Kwon, Soon-Bum;Goo, Nam-Seo;Jin, Seung-Bo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.492-497
    • /
    • 2000
  • This paper focuses on the weight minimization of radial gate, as an extention of the previous work. Radial gates are commonly used to regulate the flow-rate of general purpose dams, due to its simplicity in manufacture and control. The present study identifies the optimum position of support point for 2 and 3 arm type radial gate, which guarantees the minimum weight satisfying strength constraint condition. These optimum designs are then compared with previously constructed radial gates. The results indicate that the weights of the optimized radial gates reduce by about 20%, compared to those of the conventionally designed radial gates.

  • PDF