• Title/Summary/Keyword: 3-D imaging display

Search Result 182, Processing Time 0.036 seconds

Extraction of location of 3-D object from CIIR method based on blur effect of reconstructed POI

  • Park, Seok-Chan;Kim, Seung-Cheol;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1363-1366
    • /
    • 2009
  • A new recognition method is used to find the three-dimensional target object on integral imaging. For finding the location of a target image, amount of reconstructed reference image is needed. This method is giving accurate information of target image by correlated among reconstructed target images and reference images.

  • PDF

Convertible 3D-2D display by use of integral imaging system with plastic fiber array

  • Kim, Young-Min;Choi, Hee-Jin;Cho, Seong-Woo;Kim, Yun-Hee;Kim, Joo-Hwan;Park, Gil-Bae;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1482-1485
    • /
    • 2007
  • A three-dimensional (3D)-two-dimensional (2D) convertible display system using a plastic fiber array is proposed. The proposed system has an advantage of making use of a light source for 3D image from an arbitrary location. The optical efficiency of 3D images in the proposed system is enhanced compared with previous research.

  • PDF

Three-dimensional integral imaging using an elastic PDMS lens array

  • Kim, Yun-Hee;Kim, Yeun-Tae;Jung, Jae-Hyun;Lee, Sin-Doo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.714-717
    • /
    • 2008
  • In this paper, we propose a three-dimensional (3D) integral imaging system using an elastic lens array instead of conventional rigid lens array. The lens array is made of polydimethylsiloxane (PDMS) that is optically transparent and flexible material. We can stretch the PDMS lens array to be expanded into a certain extent, and control the lens pitch of the system easily. That flexible design enables a fine 3D integral imaging display.

  • PDF

An integrated elastomer substrate with a lens array and pixel elements for three-dimensional liquid crystal displays

  • Hong, Jong-Ho;Kim, Yeun-Tae;Kim, Yun-Hee;Lee, Byoung-Ho;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.55-59
    • /
    • 2012
  • In this paper, a concept of an integrated elastomer substrate for a three-dimensional (3D) liquid crystal display based on the integral-imaging method is presented. The elemental lens array and columnar spacers were integrated into one of the two substrates, an elastomer substrate, through an imprinting process. The integrated elastomer substrate was capable of maintaining the uniform liquid crystal (LC) cell gap and promoting homeotropic LC alignment without any surface treatment. The monolithic approach reported herein will provide a key component for 3D displays with enhanced portability through a more than 40% weight reduction compared with the conventional integral-imaging method.

Analysis of the Motion Picture Quality of Stereoscopic Three-dimensional Images

  • Choi, Hee-Jin;Jung, Jae-Hyun;Kim, Hwi;Lee, Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.383-387
    • /
    • 2010
  • The stereoscopic three-dimensional (3D) display provides a 3D image by inducing binocular disparity for the observers who wear special glasses. With the rapid progress in flat panel display technologies, the stereoscopic 3D display is becoming a new benefit-model of the current display industry, and several kinds of commercial stereoscopic 3D products have been released and are attracting people. Nowadays, the motion picture quality of the 3D image becomes as important as resolution or luminance since most of the commercial 3D products are 3D televisions or 3D monitors which are required to display a clear motion 3D image. In this paper, an analysis and simulation of the motion picture quality of stereoscopic 3D image is proposed, and a comparison of the motion picture performance among the current stereoscopic 3D technologies is also provided.

Computational Implementation of Asymmetric Integral Imaging by Use of Two Crossed Lenticular Sheets

  • Shin, Dong-Hak;Cho, Myung-Jin;Kim, Eun-Soo
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.289-293
    • /
    • 2005
  • We propose an asymmetric integral imaging method to adjust the resolution and depth of a three-dimensional image. Our method is obtained by use of two lenticular sheets with different pitches fabricated under the same F/#. The asymmetric integral imaging is the generalized version of integral imaging, including both conventional integral imaging and one-dimensional integral imaging. We present experimental results to test and verify the performance of our method computationally.

  • PDF

Optical Implementation of Incoherent Holographic 3D Display System using Modified Triangular and Mach-Zehender Interferometer (변형된 삼각 및 마하젠더 간섭계 기반의 인코히어런트 홀로그래픽 3D 디스플레이 시스템의 광학적 구현)

  • 김승철;구정식;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.524-532
    • /
    • 2004
  • In this paper, an incoherent holographic 3D imaging and display system based on the modified triangular and Mach-Zehnder interferometers is optically implemented and some experiments are carried out. Incoherent hologram of a 3D object is generated by using the hologram input system of modified triangular interferometer. Then this complex hologram is reconstructed by using the hologram output system of modified Mach-Zehnder interferometer in which two LCD spatial light modulators and a waveplate are inserted. From the experiment with two point sources having a depth difference of 100 mm each other, it is revealed that each point source can be independently reconstructed at its own focal position from the complex hologram, while both of the bias and conjugate image are simultaneously eliminated at the same time. And in the experiment with the real 3D object of two dices having a depth difference of 30 mm each other, it is also conformed that the bias and conjugate image can be effectively eliminated from the hologram pattern and each 3D dice can be also successfully reconstructed at its own focal position from the complex hologram. These experiment results finally suggest a possibility of implementing a new incoherent holographic 3D imaging and display system using the modified triangular and Mach-Zehender interferometers.

Depth-Conversion in Integral Imaging Three-Dimensional Display by Means of Elemental Image Recombination (3차원 영상 재생을 위한 집적결상법에서 기본영상 재조합을 통한 재생영상의 깊이 변환)

  • Ser, Jang-Il;Shin, Seung-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2007
  • We have studied depth conversion of a reconstructed image by means of recombination of the elemental images in the integral imaging system for 3D display. With the recombination, depth conversion to the pseudoscopic, the orthoscopic, the real or the virtual as well as to arbitrary depth without any distortion is possible under proper conditions. The conditions on the recombinations for the depth conversion are theoretically derived. The reconstructed images using the converted elemental images are presented.

Three-dimensional image processing using integral imaging method (집적 영상법을 이용한 3차원 영상 정보 처리)

  • Min, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.150-151
    • /
    • 2005
  • Integral imaging is one of the three-dimensional(3D) display methods, which is an autostereoscopic method. The integral imaging system can provide volumetric 3D image which has both vertical and horizontal parallaxes. The elemental image which is obtained in the pickup process by lens array has the 3D information of the object and can be used for the depth perception and the 3D correlation. Moreover, the elemental image which represents a cyber-space can be generated by computer process.

  • PDF