• Title/Summary/Keyword: 3-D Image

Search Result 5,123, Processing Time 0.038 seconds

Comparison of Storage Stability, Volatile Compounds and Sensory Properties between Coarsely-and Finely-Marbled 1+ Grade Hanwoo Beef Loins

  • Cho, Soohyun;Lee, Wangyeol;Seol, Kuk-Hwan;Kim, Yunseok;Kang, Sun Moon;Seo, Hyunwoo;Jung, Younbok;Kim, Jinhyoung;Ba, Hoa Van
    • Food Science of Animal Resources
    • /
    • v.40 no.4
    • /
    • pp.497-511
    • /
    • 2020
  • This study aimed at comparing the storage stability, fatty acids profile, volatile flavor compounds and eating quality of Hanwoo beef longissimus thoracis (LT) muscles between two marbling morphological groups (fineness and coarseness). The 1+ grade Hanwoo LT muscles were measured for marbling fleck morphology at the 13th thoracic vertebrae location by using computerized image analysis. Results reveal that both marbling groups had similar proximate composition (protein, fat, moisture and collagen), color and technological quality traits (p>0.05). However, the coarse marbling group presented greater C18:2n6 and polyunsaturated fatty acids contents compared to the fine marbling group (p<0.05). Furthermore, the fine marbling group presented lower volatile basic nitrogen (VBN) and 2-thiobarbituric acid reactive substance (TBARS) contents compared to the coarse marbling group after 14 d storage (p<0.05). Also, higher amounts of C18:2n6 oxidation-derived volatile compounds such as hexanal and 3-ethyl-2-methyl-1,3-hexadiene, were found in the coarse marbling group. In term of sensory aspects, the finely-marbled group received higher scores of flavor and taste compared to the coarse marbling group (p<0.05). Overall, the marbling flecks morphology partially showed its effects on the storage stability, fatty acids profile and eating quality of the 1+ grade Hanwoo beef LT muscle.

Evaluation of Streetscape by Street Planting Types using Dynamic Simulation - In the case of Ginkgo planted on the Dongdaegu-ro in Daegu - (동적 시뮬레이션을 활용한 가로수 식재유형별 가로경관 평가 - 대구광역시 동대구로 은행나무를 대상으로 -)

  • Shin, Jae-Yun;Jung, Sung-Gwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.89-103
    • /
    • 2014
  • This study analyzed the preference depending on street planting types and visual characteristics on Dongdaegu-ro located in Suseong-gu, Daegu Metropolitan City. The Single Row Roadside, Central Sidewalk Plantings, Double Row Parallel and Alternate Plantings were selected as the planting types. The plantings were divided at intervals of 4, 7 and 10 meters. A survey was conducted by dynamic simulation produced from pedestrian perspective. As a result, in single planting, the single central sidewalk planting with 4 meter-interval showed a high landscape preference 4.64. In addition, in double planting, the double alternate planting with 7 meter-interval showed the highest landscape preference 5.01. The factors that had the greatest effect on the landscape preference were 'comfortable' and 'beautiful'. It was considered that they should be preferentially taken into account in producing landscapes by planting. It was considered that they should be preferentially taken into account. It is also considered that this study will be used for objective data and planting plan for establishing the comfortable and high quality streetscape by quantitative evaluation of the visual characteristics and preference according to the street planting types.

Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging (전자포탈영상을 이용한 다엽시준기의 정도관리)

  • ;Jason W Sohn
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.151-160
    • /
    • 2003
  • The application of more complex radiotherapy techniques using multileaf collimation (MLC), such as 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT), has increased the significance of verifying leaf position and motion. Due to thier reliability and empirical robustness, quality assurance (QA) of MLC. However easy use and the ability to provide digital data of electronic portal imaging devices (EPIDs) have attracted attention to portal films as an alternatives to films for routine qualify assurance, despite concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In this study, we developed method for daily QA of MLC using electronic portal images (EPIs). EPID availability for routine QA was verified by comparing of the portal films, which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed two-test patterns of dynamic MLC were applied for image acquisition. Quantitative off-line analysis using an edge detection algorithm enhanced the verification procedure as well as on-line qualitative visual assessment. In conclusion, the availability of EPI was enough for daily QA of MLC leaf position with the accuracy of portal films.

  • PDF

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

Erosion and Sedimentation Monitoring of Coastal Region using Time Series UAV Image (시계열 UAV 영상을 활용한 연안지역 침식·퇴적 변화 모니터링)

  • CHO, Gi-Sung;HYUN, Jae-Hyeok;LEE, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.2
    • /
    • pp.95-105
    • /
    • 2020
  • In order to promote efficient coastal management, it is important to continuously monitor the characteristics of the terrain, which are changed by various factors. In this study, time series UAV images were taken of Gyeokpo beach. And the standard deviation of ±11cm(X), ±10cm(Y), and ±15cm(Z) was obtained as a result of comparing with the VRS measurement performance for UAV position accuracy evaluation. Therefore, it was confirmed that the tolerance of the digital map work rule was satisfied. In addition, as a result of monitoring the erosion and sedimentation changes using the DSM(digital surface model) constructed through UAV images, an average of 0.01 m deposition occurred between June 2018 and December 2018, and in December 2018 and June 2019. It was analyzed that 0.03m of erosion occurred. Therefore, 0.02m of erosion occurred between June 2018 and June 2019. From the topographical change analysis results, the area of erosion and sediment height was analyzed, and the area of erosion and sedimentation was widely distributed in the ±0.5m section. If we continuously monitor the topographical changes in the coastal regions by using the 3D terrain modeling results using the time series UAV images presented in this study, we can support the coastal management tasks such as supplement or dredging of sand.

Evaluation of bone quality in alveolar crest obscured by dental implants ; A pilot study by densitometric digital analysis in mandibular bone specimen (치과 임플란트 주변 협설측 치조골의 변화분석 - 하악골 시편에서의 디지털 농도분석법을 이용한 실험적 고찰 -)

  • Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.900-913
    • /
    • 1998
  • Despite of technical difficulties, the combination of occlusal projection and densitometric digital analysis may ultimately provide a means of detection of subtle bone loss at the facial and lingual side of dental implant (Oblique occlusal view is more useful for $ITI^{(R)}$ dental implant due to its contour of shoulder as like tulip flower). In this study, conventional periapical projections of x-ray beam had shown more high sensitivity to detect the bony defects than oblique occlusal projections in alveolar crest obscured by dental implants or not, even if the difference was not statistically significant. Unlike conventional periapical projections. occusal projections combined with densitometric digital analysis technique may provide a means for detection of subtle bone change at the all around of implants without obscuring effect by implant itself. Although the results from this in vitro study were performed under limited circumstances, these results might afford more possibility and versatile modality of diagnosis options to clinician in the implant practice.

  • PDF

Factors Influencing Sexual Satisfaction in Women who have had a Hysterectomy : A comparative group study (자궁적출술을 받은 부인과 자궁적출술을 받지 않은 부인의 성생활 만족 요인 분석)

  • 장순복
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.3
    • /
    • pp.357-367
    • /
    • 1990
  • This descriptive study was done to identify factors influencing sexual satisfaction in women who had had a hysterectomy and to compare these with women who had not had a hysterectomy. The purpose was to contribute theoretical understanding on which to base nursing care planning. One group of subjects were 156 women who had had a hysterectomy, between one and 18 months post surgery, living with their spouse, having no complications, and menstruating before surgery. The other group of subjects were 282 healthy women who were living with their husbands and menstruating. The study tool consisted of 108 items including item concerning personal characteristics, characteristics related to the hysterectomy, husband's support, body image, emotions, attitude toward the sexual relationship, knowledge of sexuality, sexual behavior, and sexual satisfaction. Sexual satisfaction was measured by a tool based on Derogatis Sexual Function Inventory. The range of the internal level of the study tool was from. 5208 to .9462. Data collection was done during the period from June 20 to Aug.20, 1989. The same questionnaire was used of data collection for both groups, but a mail survey method was used for the women who had had a hysterectomy, and an interview method was used for the women who had not had a hysterectomy. Data analysis was done using frequency, ratio, mean and S.D. for the characterstics of the subjects and level of sexual satisfaction. t - test or ANOVA was used for the differences between the groups with regard to the general and hysterectomy related characteristics. The relationship between the score for sex life related factors and the level of sexual satisfaction was analyzed using the Pearson Correlation, and the influencing factors on sexual satisfaction were analyzed by stepwise multiple regression. The results of this study were as follows ; 1. Mean age and income level were the only general characteristics for the two groups that were significantly different. The mean age, and income level of the group who had had a hysterectomy were 45years, and 1,150,000 won respectively, and for those who had not had a hysterectomy, 41 years and 999,000 won. 2. There was no statistical difference of the sexual satisfaction score between the two groups. 3. There was differences in the factors influencing sexual satisfaction between the two groups. Factors influencing sexual satisfaction for the group who had had a hysterectomy were husband's support (R=.5793, P=.000) and the women's Knowledge of sexuality(R=.6670, P=.000) (total variance : 33.56). On the other hand, emotional status(R=.4294, P=.000), sexual behavior(R=.4294, P=.000), husband's support(R=.5274, P=.000) and attitude towards sexual relations (R=.5412, P=.000) (total variance : 54.12) were the factors influencing sexual satisfaction in the group who had not had a hysterectomy. Since husband's support and sexuality knowledge were identified as factors influencing sexual satisfaction of women who have had a hysterectomy, it can be concluded that, before a woman who has had a hysterectomy is discharged from hospital, nurses should include strategies in the nursing care plan that will promote husband's support and the women's knowledge of sexuality.

  • PDF

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF