• Title/Summary/Keyword: 2D Imaging

Search Result 1,169, Processing Time 0.03 seconds

Three-Dimensional Printed Model of Partial Anomalous Pulmonary Venous Return with Biatrial Connection (양측 심방 연결을 형성하는 부분 폐정맥 환류 이상의 3D 프린팅 모델)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Sung-A Chang;Tae-Gook Jun;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1523-1528
    • /
    • 2020
  • Partial anomalous pulmonary venous return (PAPVR) is a rare congenital cardiac anomaly that can be difficult to detect and often remains undiagnosed. PAPVR is diagnosed using non-invasive imaging techniques such as echocardiography, CT, and MRI. Image data are reviewed on a 2-dimensional (D) monitor, which may not facilitate a good understanding of the complex 3D heart structure. In recent years, 3D printing technology, which allows the creation of physical cardiac models using source image datasets obtained from cardiac CT or MRI, has been increasingly used in the medical field. We report a case involving a 3D-printed model of PAPVR with a biatrial connection. This model demonstrated separate drainages of the right upper and middle pulmonary veins into the lower superior vena cava (SVC) and the junction between the SVC and the right atrium, respectively, with biatrial communication through the right middle pulmonary vein.

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

High Efficiency AMOLED using Hybrid of Small Molecule and Polymer Materials Patterned by Laser Transfer

  • Chin, Byung-Doo;Suh, Min-Chul;Kim, Mu-Hyun;Kang, Tae-Min;Yang, Nam-Choul;Song, Myung-Won;Lee, Seong-Taek;Kwon, Jang-Hyuk;Chung, Ho-Kyoon;Wolk, Martin B.;Bellmann, Erika;Baetzold, John P.
    • Journal of Information Display
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2003
  • Laser-Induced Thermal Imaging (LITI) is a laser addressed patterning process and has unique advantages such as high-resolution patterning with over all position accuracy of the imaged stripes of within 2.5 micrometer and scalability to large-size mother glass. This accuracy is accomplished by real-time error correction and a high-resolution stage control system that includes laser interferometers. Here the new concept of hybrid system that complement the merits of small molecule and polymer to be used as an OLED; our system can realize easy processing of light emitting polymers and high luminance efficiency of small molecules. LITI process enables the stripes to be patlerned with excellent thickness uniformity and multi-stacking of various functional layers without having to use any type of fine metal shadow mask. In this study, we report a full-color hybrid OLED using the multi-layered structure consisting of small molecules and polymers.

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

Cytoprotective Constituents of the Stem Barks of Fraxinus rhynchophylla on Mouse Hippocampal HT22 Cells and Their Antioxidative Activity (물푸레나무 수피의 생쥐 해마 유래 HT22 세포 보호와 항산화 활성 물질)

  • Jeong, Gil-Saeng;Yoon, Kwon-Ha;Kim, Hyun-Chul;Oh, Seung-Hwan;Kim, Myong-Jung;Kang, Dae-Gill;Lee, Ho-Sub;Kim, Youn-Chul
    • Korean Journal of Pharmacognosy
    • /
    • v.38 no.3 s.150
    • /
    • pp.287-290
    • /
    • 2007
  • Phytochemical investigation of the MeOH extract of the dried stem barks of Fraxinus rhynchophylla Hance (Oleaceae), as guided by cytoprotective activity against tert-butyl hydroperoxide (t-BHP)-induced cell injury in mouse hippocampal HT22 cells, furnished two coumarins, esculetin (1) and fraxetin (2). Compounds 1 and 2 had the significant cytoprotective effects on t-BHP-induced cellular oxidative injury in HT22 cells. Furthermore, compounds 1 and 2 showed potent DPPH radical scavenging effect, exhibiting $IC_{50}$ values of 14.68 and 9.64 ${\mu}M$, respectively.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

The establishment of the secondary copyright according to the production method of the 3D stereoscopic video content and the attribution (3D입체영상 콘텐츠의 제작방법에 따른 2차적 저작권 성립 여부와 귀속에 관한 연구)

  • Lee, Sung-Gil;Kim, Gwang-Ho;Kim, Joon-Gi
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.237-250
    • /
    • 2014
  • In this paper, the research problem (1) 2D to 3D stereoscopic images to create the work, the stereoscopic 3D production work in accordance with the method works independently of the 2D image derivatives can be recognized as whether the rights were discussed. (2) In addition, 3D imaging work has to be recognized as a derivatives, the copyright belongs create derivatives and about the rights of attribution investigated.

3-D OCT Image Reconstruction for Precision Analysis of Rat Eye and Human Molar (쥐 눈과 인간 치아의 정밀한 단층정보 분석을 위한 OCT 3-D 영상 재구성)

  • Jeon, Ji-Hye;Na, Ji-Hoon;Yang, Yoon-Gi;Lee, Byeong-Ha;Lee, Chang-Su
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.423-430
    • /
    • 2007
  • Optical coherence tomography(OCT) is a high resolution imaging system which can image the cross section of microscopic organs in a living tissue with about $1{\mu}m$ resolution. In this paper, we implement OCT system and acquire 2-D images of rat eye and human molar samples especially in the field of opthalmology and dentistry. In terms of 2-D images, we reconstruct 3-D OCT images which give us another inner structural information of target objects. OPEN-GL reduces the 3-D processing time 10 times less than MATLAB.

Radio-Sensitization by Piper longumine of Human Breast Adenoma MDA-MB-231 Cells in Vitro

  • Yao, Jian-Xin;Yao, Zhi-Feng;Li, Zhan-Feng;Liu, Yong-Biao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3211-3217
    • /
    • 2014
  • Background: The current study investigated the effects of Piper longumine on radio-sensitization of human breast cancer MDA-MB-231 cells and underlying mechanisms. Materials and Methods: Human breast cancer MDA-MB-231 cells were cultured in vitro and those in logarithmic growth phase were selected for experiments divided into four groups: control, X-ray exposed, Piper longumine, and Piper longumine combined with X-rays. Conogenic assays were performed to determine the radio-sensitizing effects. Cell survival curves were fitted by single-hit multi-target model and then the survival fraction (SF), average lethal dose ($D_0$), quasi-threshold dose ($D_q$) and sensitive enhancement ratio (SER) were calculated. Cell apoptosis was analyzed by flow cytometry (FCM). Western blot assays were employed for expression of apoptosis-related proteins (Bc1-2 and Bax) after treatment with Piper longumine and/or X-ray radiation. The intracellular reactive oxygen species (ROS) level was detected by FCM with a DCFH-DA probe. Results: The cloning formation capacity was decreased in the group of piperlongumine plus radiation, which displayed the values of SF2, D0, Dq significantly lower than those of radiation alone group and the sensitive enhancement ratio (SER) of D0 was1.22 and 1.29, respectively. The cell apoptosis rate was increased by the combination treatment of Piper longumine and radiation. Piper longumine increased the radiation-induced intracellular levels of ROS. Compared with the control group and individual group, the combination group demonstrated significantly decreased expression of Bcl-2 with increased Bax. Conclusions: Piper longumine at a non-cytotoxic concentration can enhance the radio-sensitivity of MDA-MB-231cells, which may be related to its regulation of apoptosis-related protein expression and the increase of intracellular ROS level, thus increasing radiation-induced apoptosis.

Automatic Generation of the Personal 3D Face Model (3차원 개인 얼굴 모델 자동 생성)

  • Ham, Sang-Jin;Kim, Hyoung-Gon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.1
    • /
    • pp.104-114
    • /
    • 1999
  • This paper proposes an efficient method for the automatic generation of personalized 3D face model from color image sequence. To detect a robust facial region in a complex background, moving color detection technique based on he facial color distribution has been suggested. Color distribution and edge position information in the detected face region are used to extract the exact 31 facial feature points of the facial description parameter(FDP) proposed by MPEG-4 SNHC(Synthetic-Natural Hybrid Coding) adhoc group. Extracted feature points are then applied to the corresponding vertex points of the 3D generic face model composed of 1038 triangular mesh points. The personalized 3D face model can be generated automatically in less then 2 seconds on Pentium PC.

  • PDF