• 제목/요약/키워드: 24-pulse

검색결과 566건 처리시간 0.025초

출력전류의 고조파 저감을 위한 24펄스 전류형 인버어터 (24 Pulse Current Source Inverter For Reducing the Harmonics in Output Currents)

  • 유철로;이공희;이성룡;한우용
    • 대한전기학회논문지
    • /
    • 제41권1호
    • /
    • pp.24-31
    • /
    • 1992
  • A 24 pulse current source inverter for reducing the harmonics in output currents is presented in this paper. The proposed system operates a 24 pulse inverter by adding only tap changing circuit which consists of several taps and static switching elements to the 12 pulse inverter, which is the double connected 3 phase 6 pulse inverter with an auto transfomer. Also to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and tap changing control angle of auto transfomer are decided by digital simulation and its validity is verified with experiment. And under the optimum condition, it is clarified that the harmonics components involved in the output current of the proposed inverter are nearly equal to those of the conventional 24 pulse inverter.

  • PDF

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

간단한 보조회로 추가에 의한 6-펄스 싸이리스터 컨버터의 다펄스화 (Pulse Multiplication of 6-Pulse Thyristor Converter with Simple Auxiliary Circuit)

  • 정재혁;최세완;이인환;황용하
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.568-574
    • /
    • 2000
  • 본 논문에서는 6-펄스 싸이리스터 컨버터에 간단한 보조회로를 추가하여 펄스 수를 증대시키는 방식을 제안한다. 제안한 방식으로 6-펄스 컨버터는 12-펄스, 18-펄스 및 24-펄스 동작을 하여 입력전류 뿐만 아니라 출략전압에서도 파형의 개선효과룹 가셔온다. 또한 입력전류 및 출력전압의 해석을 통하여 시스템의 전 위상각에 대한 보 조싸이라스터의 최적제어각을 계산하고 실험을 통하여 본 방식의 타딩성을 입증한다.

  • PDF

"황제내경"에 나타난 침자 전후의 맥진 (Pulse diagnosis procedure before and after the acupuncture in Hwangjenaekyung)

  • 배성철;신승훈;김기왕
    • 대한한의학원전학회지
    • /
    • 제24권3호
    • /
    • pp.15-25
    • /
    • 2011
  • The acupuncture procedures in Hwangjenaekyung (黃帝內經) was different to modern ones in many aspects. Especially, the role of pulse diagnosis in acupuncture was totally different and the pulse diagnosis was essential part in acupuncture therapy in Hwangjenaekyung era. We found four noteworthy features on the pulse diagnosis before and after acupuncture in Hwangjenaekyung : (1) Pulse diagnosis was a mandatory process in acupuncture (2) Doctors who used pulse diagnosis in 12 meridians (十二經脈遍診脈法), pulse diagnosis in 9 points of 3 body parts (三部九候脈法), and comparative pulse diagnosis between radial artery and carotid artery (人迎寸口對比脈法) followed the former rule ((1)). (3) The major pulse features to detect before and after acupuncture were conversion between the vacuous pulse (虛脈) and the replete pulse (實脈), and conversion between slippery pulse (滑脈) and rough pulse (澁脈). (4) Deukki (得氣, Deqi) was synonym of Kiji (氣至), and it referred to the changes of arterial pulse, not the sensation followed by acupuncture manipulation.

A Zigzag Connected Auto-Transformer Based 24-Pulse AC-DC Converter

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.235-242
    • /
    • 2008
  • In this paper, a 24-pulse AC-DC converter is designed, modeled, simulated, and developed to feed non-isolated varying loads. The proposed AC-DC converter configuration consists of an auto-transformer based on zigzag connection to overcome current harmonic problems in AC mains. It improves power quality at AC mains and it meets IEEE-519 standard requirements at varying loads. A set of power quality indices on input AC mains and on DC buses for a load fed from 6-pulse and 12-pulse AC-DC converters is also given to compare their performance. It is observed that input current total harmonic distortion(THD) of less than 8% is possible with the proposed topology of AC-DC converter at varying loads.

Pulse Multiplication in Autotransformer Based AC-DC Converters using a Zigzag Connection

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.191-202
    • /
    • 2007
  • This paper deals with pulse multiplication in zigzag connected autotransformer based 12-pulse AC-DC converters feeding vector controlled induction motor drives (VCIMD) for improving the power quality at the point of common coupling (PCC) without using a Zero-Sequence-Blocking-Transformer (ZSBT). The proposed 24-pulse AC-DC converter is based on the principle of DC ripple re-injection technique for pulse multiplication and harmonic mitigation. The design of the autotransformer is carried out for the proposed AC-DC converter and the effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed AC-DC converter. Test results from a laboratory developed prototype, along with simulated results, are presented to validate the design and model of the proposed 24-pulse AC-DC converter.

새로운 고전압 대전력용 24펄스 다이오드 정류기 시스템 (A New 24-Pulse Diode Rectifier for High Voltage and High Power Application)

  • 최세완;김기용
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.304-309
    • /
    • 1999
  • 본 논문에서는 새로운 24펄스 다이오드 정류기 시스템을 제안한다. 제안하는 다이오드 정류기 시스템은 기존의 직렬형 12펄스 다이오드 정류기에 수동의 보조회로를 추가함으로서 구성되어지고, 입력전류는 제 22차까지의 고조파가 제거되어 거의 정현파에 가까운 전류 파형을 얻는다. 또한, 출력 전압은 n=24k, k=1,2,3... 의 고조파 성분을 갖는 24펄스 특성를 나타낸다. 더욱이, 이 보조회로의 용량은 출력용량에 비하여 매우 작으며, 능동 스위칭소자를 사용하지 않으므로 외란에 강하고 구현이 간단하다. 따라서, 본 방식은 중·대용량급의 고전압 비제어(uncontrolled) 직류전원이 필요한 인버터나 무정전 전원장치등의 앞단에서 입력고조파의 저감에 경제적이고 효율적이다. 220V, 3KVA 정류기 시스템의 실험을 통하여 제안한 시스템의 타당성을 검증하였다.

  • PDF

테이퍼를 갖는 맥동관의 2차원 해석모델 (Two-Dimensional Analysis Model for Tapered Pulse Tubes)

  • 백상호;정은수
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.668-676
    • /
    • 2000
  • A two-dimensional model for pulse tubes with tapered cross-section was proposed. Net enthalpy flow and steady mass streaming were investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. Steady mass flux profiles show good agreement with the previous approximate solution. It was shown that steady mass streaming can be reduced by tapering a pulse tube and by increasing the length of a pulse tube. Effects of the velocity phase angle and frequency on steady mass streaming were shown.

간단한 보조회로 추가에 의한 6-펄스 싸이리스터 컨버터의 다펄스화 (Pulse Multiplication of 6-Pulse Thyristor Converter with Simple Auxiliary Circuit)

  • 오준용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.294-298
    • /
    • 2000
  • A new pulse multiplication technique based on 6-pulse thyristor converters is proposed in this paper. With the proposed technique 12-pulse 18-pulse and 24-pulse operations have been obtained both on the input current and on the output voltage. A control strategy over the whole range of phase angle is provided along with sophisticated input current and output voltage analysis. Experimental results from a laboratory prototype verify the proposed theory.

  • PDF

Design Considerations for Auto-Connected Multi-Pulse Rectiviers for High Power AC Motor Drives

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.413-422
    • /
    • 1999
  • Auto-connected multipulse(12/24pulse) rectifier schemes are cost effective methods for reducing line current hamonics in PWM drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations In particular, excursion of dc-link voltage at no load, effect of pre-existing voltage distortion, impedance mismatches, unequal diode drops on rectifier current sharing and performance, are fully analyzed, Several corrective measures to improve the performance of 12/24­pulse rectifier systems are also discussed. Finally, experimental results on a 460V, 60Hz 400kVA commercial ASD, retrofitted with 12/24pulse rectifier systems are discussed in detail.

  • PDF