• 제목/요약/키워드: 2-D resistivity survey

검색결과 72건 처리시간 0.021초

지구물리학적 방법에 의한 화산 칼데라 지역의 지질구조 연구 (Study of geological structure in area of Hwasan caldera using geophysical method)

  • 권병두;이희순;양준모;박계순;엄주영;김동오
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.267-272
    • /
    • 2007
  • Uiseong subbasin belonging to Kyungsang basin resulted from volcanic activity in the late Cretaceous. In this study, we carry out MT and gravity survey at the Hwasan caldera, which was formed of volcanic and abyssal rocks complex, then analyze and identify geological substructure. Potential survey such as gravity and magnetic survey has been mainly carried out in former studies, so depth information for understanding substructure was not enough. To complement a potential survey, we use MT method, which has high vertical resolution. Moreover we make a simple 2D model comparing with former study. The result of MT and gravity 2D modeling shows that this area is roughly composed of 3 layers; The bottom layer is a basement. In the second layer, intrusive rocks having high resistivity is placed along the ring faults and the sedimentary layer of low resistivity is inside caldera. The highest layer is alluvium. To comprehend the 3D structure of the Hwasan caldera, we perform 3D gravity inversion, and construct the 3D model from the result of 3D gravity inversion. MT responses are calculated by using the constructed 3D model and the 3D model of the Hwasan caldera's structure is suggested after comparing the calculated values with the observed values at MT line.

  • PDF

전기비저항 탐사를 이용한 노은매립장 침출수 분포에 관한 연구 (A Study on Electrical Resistivity Geophysical Surveys of the Noen Landfill Site)

  • 김준경;홍상표;김광렬;조용진
    • 환경영향평가
    • /
    • 제13권5호
    • /
    • pp.223-230
    • /
    • 2004
  • The electrical resistivity prospecting method with dipole-dipole array were applied in order to survey 3-D structure characteristics of the Noen landfill site. For the electrical resistivity prospecting, 3 line of measurements were established parallel to the main boundary of the Noen landfill site and additional 2 lines were also established perpendicular to the existing 3 lines for the effective investigation of the landfill site. The results showed that the uppermost layer of the landfill site is believed to be stabilized generally based on the characteristics of electrical resistivity distribution. Lowest layer was partially polluted by the leachate.

3차원 IP 탐사의 모형 응답 계산 (Three Dimensional Induced Polarization Modeling)

  • 남명진;서정희
    • 지구물리와물리탐사
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2001
  • 지하 환경 오염 현황 조사 및 대규모 토목 구조물 현장의 지반 조사 시 대상 지역의 정밀 영상화 자료가 요구된다. 이를 위해서 다양한 물리 탐사 기법이 통합되어 적용될 필요가 있다. 본 연구에서는 현재 국내에서 가장 활발하게 활용되고 있는 물리탐사 방법인 전기비저항 탐사와 동시 탐사가 가능하다는 장점이 있는 유도 분극 탐사 자료에 대한 고찰한다. 이 논문에서는, 기존의 3차원 전기비저항 모형 반응 계산 알고리듬을 바탕으로 3차원 충전성 모형 반응 계산을 하고자한다. 본 연구에서의 3차원 모형 응답 반응 계산의 결과를 2차원 모형 반응 계산 결과와 비교하여 모형 반응 계산알고리듬의 타당함을 확인하였다. 본 연구는 앞으로 이루어질 유도 분극 탐사자료에 대한 연구의 기반이 되리라 기대된다.

  • PDF

대형 고분에서의 3차원 전기비저항 탐사 (3-D Resistivity Imaing of a Large Scale Tumulus)

  • 오현덕;이명종;김정호;신종우
    • 지구물리와물리탐사
    • /
    • 제14권4호
    • /
    • pp.316-323
    • /
    • 2011
  • 대형 고분의 발굴 조사를 위한 전기비저항 탐사법의 적용 가능성을 시험하기 위하여, 나주 복암리 3호분에 대하여 3차원 전기비저항 탐사를 수행하였다. 높은 해상도의 지하구조 영상을 얻기 위해서는 고분의 정확한 지형 구조 및 전극 위치에 대한 정보 획득이 필수적이다. 이에 따라 문화재 발굴 조사에서 사용하는 방법인 실을 이용한 구획설정법을 응용하여 전극을 설치하였다. 탐사 자료는, 전극 간격은 2 m, 측선 간격은 1 m로 하여 얻었으며, 각 탐사 측선은 상대적으로 1 m 엇갈리게 배열함으로써 전체적으로 고분에 대하여 1 m ${\times}$ 1m 크기의 격자망으로 구성하였다. 탐사 자료에 대하여 3차원 전기비저항 영상화를 수행하고 이를 기존의 발굴 조사 결과와 대비하였으며, 이로부터 확인된 매장 유구 분포와 전기비저항 영상이 매우 잘 일치함을 확인하였다. 이 연구를 통하여 대형 고분에서 매장 유구를 조사할 때 3차원 전기비저항 영상화 기술이 매우 유용함을 밝혔다.

2차원 전기비저항 탐사에 사용되는 ROLL-ALONG 기법에 대한 고찰 (A STUDY ON THE ROLL-ALONG TECHNIQUE USED IN 2D ELECTRICAL RESISTIVITY SURVEYS)

  • 한원석;윤종렬
    • 지구물리
    • /
    • 제6권3호
    • /
    • pp.155-164
    • /
    • 2003
  • 차원 전기비저항 탐사자료의 획득에 널리 사용되는 roll-along 기법의 타당성과 효율성을 현재 통용되고 있는 쌍극자-쌍극자 배열법(dipole-dipole array) 과 베너 슐럼버저 (Wenner-Schlumberger array)배열법 의 경우에 대하여 수치 모델링을 통해 분석하였다 천부 정보를 상대적으로 많이 포함하고 있는 가단면도 상부에 위치한 자료들은 기법에 의한 자료의 누락이 없으므로 천부의 전기비저항 이상대는 두 배열법에서 모두 성공적으로 영상화되었다 그러나 비교적 심부에 위치한 이상대는 roll-along기법으로 야기되는 자료의 누락으로 인해 왜곡된 형태로 나타날 수 있으며 이 현상은 자료획득의 수평 범위가 상대적으로 빈약한 베너 슐럼버저 배열법에서 더 크게 나타나는 것으로 확인되었다 또한 실제 탐사에서 쌍극자 쌍극자 배열법은 S/N비가 낮아 유한한 전극 개수로 구현할 수 있는 최대전극전개계수($n_max$) 까지 전극을 전개할 수 없는 경우가 많은 이유로 roll-along기법으로 인한 자료의 누락이 적게 나타나지만 베너 슐럼버저 배열법의 경우에는 S/N비가 높아 ($n_max$)까지 전극을 전개하게 되어 자 료의 누락이 커지므로 역산 단면의 왜곡이 야기될 수 있는 것으로 분석되었다 따라서 동일한 기본전극간격 ($a$)과($n$)을 사용하였을 때 쌍극자 쌍극자 배열법보다 깊은 median depth(Edwards, 1977)를 제공하는 베너 슐럼버저 배열 법의 경우 roll-along기법에 의한 자료의 왜곡을 줄이고 효율적인 현장 작업을 위하여 ($n_max$)보다는 자료의 누락이 무시될 수 있는 ($n_prob$)을 기준으로 가탐심도에 적합한 를 결정한 후 측선 중첩구간이 전체 측선 길이의 3/4이 되도록 전극을 전진 배치하는 전극배열 방식이 추천되며 이는 수치 모델링을 통해 확인되었다.

  • PDF

Estimation of the zone of excavation disturbance around tunnels, using resistivity and acoustic tomography

  • Suzuki Koichi;Nakata Eiji;Minami Masayuki;Hibino Etsuhisa;Tani Tomonori;Sakakibara Jyunichi;Yamada Naouki
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.62-69
    • /
    • 2004
  • The objective of this study is to estimate the distribution of a zone disturbed by excavation (EDZ) around tunnels that have been excavated at about 500 m depth in pre-Tertiary hard sedimentary rock. One of the most important tasks is to evaluate changes in the dynamic stability and permeability of the rock around the tunnels, by investigating the properties of the rock after the excavation. We performed resistivity and acoustic tomography using two boreholes, 5 m in length, drilled horizontally from the wall of a tunnel in pre-Tertiary hard conglomerate. By these methods, we detected a low-resistivity and low-velocity zone 1 m in thickness around the wall of the tunnel. The resulting profiles were verified by permeability and evaporation tests performed at the same boreholes. This anomalous zone matched a high-permeability zone caused by open fractures. Next, we performed resistivity monitoring along annular survey lines in a tunnel excavated in pre-Tertiary hard shale by a tunnel-boring machine (TBM). We detected anomalous zones in 2D resistivity profiles surrounding the tunnel. A low-resistivity zone 1 m in thickness was detected around the tunnel when one year had passed after the excavation. However, two years later, the resistivity around the tunnel had increased in a portion, about 30 cm in thickness, of this zone. To investigate this change, we studied the relationship between groundwater flow from the surroundings and evaporation from the wall around the tunnel. These features were verified by the relationship between the resistivity and porosity of rocks obtained by laboratory tests on core samples. Furthermore, the profiles matched well with highly permeable zones detected by permeability and evaporation tests at a horizontal borehole drilled near the survey line. We conclude that the anomalous zones in these profiles indicate the EDZ around the tunnel.

물리탐사 결과 복합해석을 통한 방조제 제체 정밀안전진단 사례 (Case History for Safe Diagnosis of Embankment Dike using Composite Analysis of Various Geophysical surveys)

  • 송성호;성백욱;김영규;강미경;이규상;김양빈
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.107-112
    • /
    • 2007
  • To establish the reinforce region and technique through the embankment dike after identifying the region of seawater inflow, we carried out small-loop electromagnetic (EM) survey, electrical resistivity survey and refraction seismic method. We also analyzed the distribution of electrical conductivity in reservoir with depth every two month and monitored water level variations with tidal variation in four observation wells located at seaside and reservoir side in order to analyze the relationship with survey results. From both the cross-correlation between tidal and water level variation at four wells and the distribution of electrical conductivity in reservoir with depth, the major portion of seawater inflow are identified through the embankment dike. From electromagnetic and electrical resistivity survey results, it was found that the seawater inflow were happened through several small regions at seaside and became wider near reservoir side. The 2-D inversion sections of refraction seismic method showed that the pebble-bearing sand layer is spread over the whole region with two to four width. From the this study, small-loop EM, electrical resistivity and refraction seismic surveys accompany with the distribution of electrical conductivity in reservoir with depth and the monitoring results for water level variations are revealed to be effective to identify seawater inflow pathway through embankment dike and to establish the reinforce region and technique through the embankment dike.

  • PDF

석회석 광산지역 지반침하 분석을 위한 물리탐사 기술 적용 연구 (A Geophysical Survey of Subsidence area around Limestone Mine Sites)

  • 홍진표;지윤수;오석훈;최성웅
    • 지구물리와물리탐사
    • /
    • 제18권4호
    • /
    • pp.207-215
    • /
    • 2015
  • 지반침하가 발생한 두 곳의 석회석 광산 지역에서 전기비저항 탐사를 수행하여 침하 원인과 향후 위험지역을 추정하고자 하였으며, 해석의 한계성을 극복하기 위해 암반공학적 해석을 수행하여 광산 개발과의 연계성을 검토하고자 하였다. 연구지역은 점토와 모래질 토층의 석회석 광산 인근 지대(연구지역 1)와 석회석 광산과의 연관성이 예측되는 채굴적 상부 지대(연구지역 2)를 대상으로 하였다. 연구지역 1, 2의 2차원 전기비저항 탐사 결과, 침하 발생 위치 하부에서 각각 70 ~ 120 ohm-m, 20 ~ 50 ohm-m의 상대적으로 저비저항 이상대가 확인되었다. 연구지역 1은 2차원 전기비저항 단면을 파악하여 3차원 역산 해석을 통해 지반침하의 가능성을 확인하였다. 연구지역 2는 침하가 발생하고 이상대가 관찰된 측선 7번에 대하여 암반공학적 안정성 해석을 실시하고, 침하의 원인과 향후 침하 발생 가능성을 확인하였다.

하천제방의 안전성 평가기법 연구 (A Study on Assessment Techniques of Levee Safety)

  • 윤종렬;김진만;최봉혁
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.111-116
    • /
    • 2005
  • 시트파일과 그라우팅 차수벽의 차수효과를 비교 판정하고 제방하부에서 발생하는 파이핑 현상을 감지하기 위하여 합천군의 덕인2제를 대상으로 갈수기와 우수기에 걸쳐 2차원 및 3차원 전기비저항탐사를 실시하였다. 자료의 해석결과 2차원이나 3차원탐사 모두 시트 파일과 일반 그라우팅 차수벽의 경계부나 육안으로 관찰된 파이핑 발생지점을 비교적 정확하게 탐지하였다. 또한 제방붕괴의 주요원인중 하나인 배수통문 배면의 공동을 조사하기 위하여 GPR탐사를 실시하였으나 구조물에 배근된 철근의 영향으로 만족할 만한 자료를 얻을 수 없었다. 배수통문 구조물의 특성상 여타 지구물리탐사법의 적용이 어려우므로 본 연구에서는 통문 하부 공동의 연결성을 평가할 수 있는 수리응답시험을 제안하였다.

  • PDF

매립장 침출수 환경 재해에 관한 연구 (Analysis of Environmental Hazard by the Leachate from Disposal Waste)

  • 김준경;배효준;최오순
    • 한국방재학회 논문집
    • /
    • 제3권4호
    • /
    • pp.145-151
    • /
    • 2003
  • 생활폐기물 및 산업폐기물은 인간의 활동으로부터 배출되며 소각법 혹은 매립법 또는 2가지 방법을 동시에 이용하여 처리되고 있다. 특히 매립법은 침출수로 인하여 매립지가 있는 지역의 지하수계를 심각하게 오염시켜 환경재해를 발생시키고 있다. 따라서 오염지역의 침출수 오염특성을 3차원적으로 조사하여 환경재해를 최소화하는 것이 중요하다. 본 연구는 비위생 매립지인 충주시 노은 매립장의 3차원적 침출수 오염특성을 조사하였다. 조사를 위한 1개 측선의 방향은 주된 매립지 경계와 평행하도록 설치하였다. 노은 매립장을 탐사한 결과 가장 상부층은 안정화가 완전하게 진행되었으나 가장 하부층은 부분적으로 침출수가 일부 존재하는 것으로 분석되었다.