• Title/Summary/Keyword: 2 order system

Search Result 14,811, Processing Time 0.052 seconds

Development of a Soil Hardness Meter with Strain Gages (스트레인 게이지를 이용(利用)한 토양(土壤) 경도계(硬度計)의 개발(開發) (I))

  • Kim, Tae Han;Lee, Ki Myung;Jang, Ik Joo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.95-100
    • /
    • 1983
  • A soil hardness meter with strain gages was developed in order to measure the hardness of the soil. Soil hardness tests were conducted at the laboratory based on this measuring system. Also, these results were compard with that from the cone penetrometer which is widely used for this purpose. The following conclusions were drawn from the results. 1. Since the correlation coefficient of calibration curve obtained from the soil hardness meter with strain gages was 0.99876 and that of calibration curve obtained from the cone penetrometer with dial gage was 0.97150, the soil hardness meter with strain gages was more recomendable than that with dial gage for this purpose. 2. Standard deviations of soil hardness for sands and soil of paddy field when the soil hardness meter with strain gages was used were 6.794 and 8.271, respectively and that of soil hardness for sands and soil of paddy field when the cone penetrometer with dial gage was used were 7.490 and 9.169, respectively. Thus, the soil hardness meter with strain gages seemed to have lower measuring error than with dial gage.

  • PDF

A Study on Matching Method of Hull Blocks Based on Point Clouds for Error Prediction (선박 블록 정합을 위한 포인트 클라우드 기반의 오차예측 방법에 대한 연구)

  • Li, Runqi;Lee, Kyung-Ho;Lee, Jung-Min;Nam, Byeong-Wook;Kim, Dae-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • With the development of fast construction mode in shipbuilding market, the demand on accuracy management of hull is becoming higher and higher in shipbuilding industry. In order to enhance production efficiency and reduce manufacturing cycle time in shipbuilding industry, it is important for shipyards to have the accuracy of ship components evaluated efficiently during the whole manufacturing cycle time. In accurate shipbuilding process, block accuracy is the key part, which has significant meaning in shortening the period of shipbuilding process, decreasing cost and improving the quality of ship. The key of block accuracy control is to create a integrate block accuracy controlling system, which makes great sense in implementing comprehensive accuracy controlling, increasing block accuracy, standardization of proceeding of accuracy controlling, realizing "zero-defect transferring" and advancing non-allowance shipbuilding. Generally, managers of accuracy control measure the vital points at section surface of block by using the heavy total station, which is inconvenient and time-consuming for measurement of vital points. In this paper, a new measurement method based on point clouds technique has been proposed. This method is to measure the 3D coordinates values of vital points at section surface of block by using 3D scanner, and then compare the measured point with design point based on ICP algorithm which has an allowable error check process that makes sure that whether or not the error between design point and measured point is within the margin of error.

CLINICAL EVALUATION OF CHILDREN WITH INATTENTION AND HYPERACTIVITY IN A PSYCHIATRIC CLINIC (주의산만과 과잉운동을 주소로 하는 정신과 내원 아동들의 임상 평가)

  • Kweon, Yong-Sil
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.13 no.1
    • /
    • pp.93-103
    • /
    • 2002
  • The aim of this study is to examine the diagnostic profiles and related clinical variables of children with attention and hyperactivity in psychiatric outpatient clinic. Seventy one children with age range of 5 to 14 were diagnosed by DSM-IV, and assessment battery including KEDI-WISC, KPI-C, ADS(ADHD Diagnostic System) were completed. The subjects were divided into 3 diagnostic groups:ADHD only(n=17), ADHD comorbid(n=27), Other diagnosis(n=27). The results were as follows:In ADHD comorbid group, tic disorder, developmental language disorder, borderline intellectual function, oppositional defiant/conduct disorder, and learning disorder were combined in descending order. Other diagnosis group consisted of tic disorder, borderline intellectual function, depression/anxiety, oppositional defiant/conduct disorder, and others. There were significant differences in IQ, PIQ, and VIQ among the three groups, and ADHD only group showed higher scores of IQ and VIQ than ADHD comorbid group. On the KPI-C, there were no significant differences in all subscales among the three groups. On the visual ADS, omission error and sensitivity showed significant differences among the three groups, and ADHD comorbid group represented higher omission error and lower sensitivity than other diagnostic group. The findings indicated that the inattention and hyperactivity symptoms could be diagnosed into diverse psychiatric disorders in child psychiatry, and ADHD children with comorbidity will show more problems in academic performance and school adjustment.

  • PDF

An Experimental Study on Bearing Capacity of Drilled Shaft with Mid-size (중구경 현장타설말뚝의 지지력 특성에 관한 실험적 연구)

  • Lee, Kwang-Wu;You, Seung-Kyong;Park, Jeong-Jun;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.263-272
    • /
    • 2019
  • This paper describes the results of bearing capacity using field loading test of pile, in order to extend the applicability of drilled shaft with mid-size, and the results were compared with the prediction results of design bearing capacity by empirical formular. The static load test result showed that the allowable bearing capacity of high pile strength was about 2.4 times higher than that of low pile strength. The dynamic load test result showed that the allowable bearing capacity of high pile strength was about 1.4 times~1.5 times higher than that of low pile strength. The comparison result of allowable bearing capacity between static and dynamic load test showed that the difference of allowable load ranged from 3% to 6% under the same settlement conditions. As a result of comparing the ultimate bearing capacity by load test and design bearing capacity, it was found that the FHWA proposed equation could be more reasonable than the other proposed equation in load sharing ratios of end bearing and skin friction.

Analysis of Stream Depletion Rate by Groundwater Abstraction in Leaky Aquifer (누수대수층 지하수 양수에 따른 하천수 감소율 거동 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.1001-1008
    • /
    • 2017
  • This study was to evaluate the stream depletion rate from groundwater pumping with varying stream-well distance, aquifer transmissivity, storage coefficient, leakage coefficient, streambed hydraulic conductance using the Zlotnik and Tartakovsky analytical solution which considers a two-layer leaky aquifer-stream-well system. For the hydraulic conditions applied in this study, the streambed hydraulic conductance and the aquitard leakage coefficient were assessed to have a dominant influence on the stream depletion rate. In order to evaluate the applicability of Zlotnik and Tartakovsky analytical solution ignoring the change in the drawdown in the lower aquifer and applying the fixed head boundary condition, the solution was compared with Hunt analytical solution derived from the more practical conditions simultaneously taking into account the drawdown changes in the upper and lower aquifers. As a result, the Zlotnik and Tartakovsky analytical solution is suitable for predicting short-term effects of less than one year in the pumping period, and when the stream depletion factor (SDF) is greater than 2,500 days, or when the product of the leakage coefficient and the stream-well distance is less than 10 cm/s.

A numerical study of the effects of the ventilation velocity on the thermal characteristics in underground utility tunnel (지하공동구 터널내 풍속 변화에 따른 열특성에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Ra, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • In this research, thermal design data such as heat transfer coefficient on the wall surface required for ventilation system design which is to prevent the temperature rise in the underground utility tunnel that three sides are adjoined with the ground was investigated in numerical analalysis. The numerical model has been devised including the tunnel lining of the underground utility tunnel in order to take account for the heat transfer in the tunnel walls. The air temperature in the tunnel, wall temperature, and the heating value through the wall based on heating value(117~468 kW/km) of the power cable installed in the tunnel and the wind speed in the tunnel(0.5~4.0 m/s) were calculated by CFD simulation. In addition, the wall heat transfer coefficient was computed from the results analysis, and the limit distance used to keep the air temperature in the tunnel stable was examined through the research. The convective heat transfer coefficient at the wall surface shows unstable pattern at the inlet area. However, it converges to a constant value beyond approximately 100 meter. The tunnel wall heat transfer coefficient is $3.1{\sim}9.16W/m^2^{\circ}C$ depending on the wind speed, and following is the dimensionless number:$Nu=1.081Re^{0.4927}({\mu}/{\mu}_w)^{0.14}$. This study has suggested the prediction model of temperature in the tunnel based on the thermal resistance analysis technique, and it is appraised that deviation can be used in the range of 3% estimation.

The Agricultural Utilization of Daecheong Lake Sediments and Algae (대청호(大淸湖) 저니(底泥) 및 조류(藻類)의 농업적(農業的) 활용(活用) 연구(硏究))

  • Chang, Ki-Woon;Lim, Jae-Shin;Lee, In-Bog
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.2
    • /
    • pp.111-116
    • /
    • 1994
  • These studies were carried out to investigate the possibility on the agricultural utilization of lake sediment collected in the Daecheong Lake. Several parameters to estimate the degree of maturity of compost by windrow system were tested during a 50 day periods, and the results were as follows : During the composting of Daecheong Lake sediment, C/N ratio decreased gradually from 18.9 at the beginning to 13.1 at the final, while CEC increased from 33.5me/100g to 62.5me/100g. The temperature of lake sediment pile was the highest as $52^{\circ}C$ at 15th day and then decreased slowly until $30^{\circ}C{\sim}40^{\circ}C$ after 50 days. The results may be suggested that Daecheong Lake sediment compost reaches an acceptable level of stability after about 50 days. In order to know the effect of the Lake sediment and its compost on the growth of tomato(Lycopersicum esculentum M.), pot experiments were performed. The appiication of lake sediment(AS) itself, sediment organic fertilizer(SOF), and NPK mixed with sediment organic fertilizer(NSF) was more effective for tomato plant height, fresh and dry weight, and chlorphyll content than those of control treatment. Also, the lake sediment compost improved the physico-chemical properties of soil such as pH, total carbon, total nitrogen, available phosphorous and CEC.

  • PDF

Research on Fabrication of Silicon Lens for Optical Communication by Photolithography Process (포토리소그래피를 통한 광통신용 실리콘 렌즈 제작 및 특성 연구)

  • Park, Junseong;Lee, Daejang;Rho, Hokyun;Kim, Sunggeun;Heo, Jaeyeong;Ryu, Sangwan;Kang, Sung-Ju;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.2
    • /
    • pp.35-39
    • /
    • 2018
  • In order to improve the coupling efficiency, a collimator lens that collects the light emitted from the laser diode at a wide angle to the core of the optical fiber is essential. Glass mold method using a mold is widely used as a collimator lens currently used. Although this method is inexpensive to produce, it is difficult to form precisely and quality problems such as spherical aberration. In this study, the precision of surface processing was improved by replacing the existing glass mold method with the semiconductor process, and the material of the lens was changed to silicon suitable for the semiconductor process. The semiconductor process consists of a photolithography process using PR and a dry etching process using plasma. The optical coupling efficiency was measured using an ultra-precision alignment system for the evaluation of the optical characteristics of the silicon lens. As a result, the optical coupling efficiency was 50% when the lens diameter was $220{\mu}m$, and the optical coupling property was 5% or less with respect to the maximum optical coupling efficiency in the lens diameter range of $210-240{\mu}m$.

Case Study on the Leadership Shifts in Smart Phone Industry: Rise of China and Falling Behind of Korea (스마트폰 산업에서의 주도권 이전: 중국의 부상과 우리나라의 쇠퇴에 관한 사례 연구)

  • Kwak, Kiho;Lee, Eunju
    • Journal of Technology Innovation
    • /
    • v.26 no.2
    • /
    • pp.95-128
    • /
    • 2018
  • Since mid and late 2000s, the smartphones has been widely diffused and Korea ranked first in global smartphone market in 2011 thanks to its rapid adoption of Android operating system, technology capability accumulated in featurephone development, vertical integration on smartphone production and premium positioning. However, Korea fell behind because of the rise of another latecomer, China, in four years (2015) after it recorded the top position globally. How did the leadership change occurred in the smartphone industry so rapidly? In order to answer the question, we investigated three favorable windows of opportunity for the rise of China, which are technological, demand, and institutional, and the strategic responses of Chinese firms as well as the rigidity and complacency with the past success of Korean firms. Our findings contribute to the extension of 'catch-up cycle' theory as well as provide in-depth insights for strategies and policies settings to overcome the recent rise of China in information and communication technology sector for Korea.

Comparison of SpineJet$^{TM}$ XL and Conventional Instrumentation for Disk Space Preparation in Unilateral Transforaminal Lumbar Interbody Fusion

  • Huh, Han-Yong;Ji, Cheol;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.370-376
    • /
    • 2010
  • Objective : Although unilateral transforaminal lumbar interbody fusion (TLIF) is widely used because of its benefits, it does have some technical limitations. Removal of disk material and endplate cartilage is difficult, but essential, for proper fusion in unilateral surgery, leading to debate regarding the surgery's limitations in removing the disk material on the contralateral side. Therefore, authors have conducted a randomized, comparative cadaver study in order to evaluate the efficiency of the surgery when using conventional instruments in the preparation of the disk space and when using the recently developed high-pressure water jet system, SpineJet$^{TM}$ XL. Methods : Two spine surgeons performed diskectomies and disk preparations for TLIF in 20 lumbar disks. All cadaver/surgeon/level allocations for preparation using the SpineJet$^{TM}$ XL (HydroCision Inc., Boston, MA, USA) or conventional tools were randomized. All assessments were performed by an independent spine surgeon who was unaware of the randomizations. The authors measured the areas (cm2) and calculated the proportion (%) of the disk surfaces. The duration of the disk preparation and number of instrument insertions and withdrawals required to complete the disk preparation were recorded for all procedures. Results : The proportion of the area of removed disk tissue versus that of potentially removable disk tissue, the proportion of the area of removed endplate cartilage, and the area of removed disk tissue in the contralateral posterior portion showed 74.5 ${\pm}$ 17.2%, 18.5 ${\pm}$ 12.03%, and 67.55 ${\pm}$ 16.10%, respectively, when the SpineJet$^{TM}$ XL was used, and 52.6 ${\pm}$ 16.9%, 22.8 ${\pm}$ 17.84%, and 51.64 ${\pm}$ 19.63%, respectively, when conventional instrumentations were used. The results also showed that when the SpineJet$^{TM}$ XL was used, the proportion of the area of removed disk tissue versus that of potentially removable disk tissue and the area of removed disk tissue in the contralateral posterior portion were statistically significantly high (p < 0.001, p < 0.05, respectively). Also, compared to conventional instrumentations, the duration required to complete disk space preparation was shorter, and the frequency of instrument use and the numbers of insertions/withdrawals were lower when the SpineJet$^{TM}$ XL was used. Conclusion : The present study demonstrates that hydrosurgery using the SpineJet$^{TM}$ XL unit allows for the preparation of a greater portion of disk space and that it is less traumatic and allows for more precise endplate preparation without damage to the bony endplate. Furthermore, the SpineJet$^{TM}$ XL appears to provide tangible benefits in terms of disk space preparation for graft placement, particularly when using the unilateral TLIF approach.