• 제목/요약/키워드: 1mm 응력

검색결과 539건 처리시간 0.03초

임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향 (THREE-DIMENTIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION FOR DIFFERENT IMPLANT THREAD SLOPE)

  • 서영훈;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.482-491
    • /
    • 2007
  • Statement of problem: The screws of dental implant, having various thread types, can be categorized into different classes by their geometrical form, and each type transmits dissimilar amount and form of stress to alveolar bone. Purpose: The purpose of this study was to find an inclination angle of the screw thread that is favorable in distributing the stresses to alveolar bone. Material and methods: In this study, We used three dimensional finite element analysis with modeling having three types of thread inclination angles and fixed pitch-0.8 mm (single thread type with $3.8^{\circ}$ inclination, double thread type with $7.7^{\circ}$ inclination, triple thread type with $11.5^{\circ}$ inclination). Results: The results obtained from this study were as follows; 1. When the number of thread increased, the amount of Von-Mises stress was reduced since the generated stress was effectively distributed. 2. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants when comparing the magnitude of the maximum principal stress double thread had least amount of stress. This shows that the double thread screw gave best result. Conclusion: In conclusion, double, and triple thread screws were found to be more effective on distribution of the stress than the single thread screws. But, increasing in the thread inclination angle such as triple thread screw relate on the magnitude of the maximum principal stress affecting on the alveolar bone can become problematic. Thus, effective combination of thread number and thread inclination angle can help prolonging the longevity of implant.

사람 소구치부위에서 주위골의 구조 및 밀도변화가 교합력에 의한 치아의 응력분포에 미치는 영향 (The effect of varying peripheral bone structure and bone density on the occlusal stress distribution of human premolar regions)

  • 서예준;심준성;이근우;정문규;이호용
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.7-15
    • /
    • 2003
  • This study used FEM(Finite Element method) based on micro-CT images to see the effects of occlusal force distribution with varying bone density and structure. the mandibular premolar region from human cadaver, thickness of 10mm was imaged using micro-CT. the cross sectional images were taken every $10{\mu}m$. these were reconstructed and the longitudinal image at the mid point of mesiodistal of the speciman was obtained for the specimen for the FEM. The stress disribution produced by a vertical force at 100N and 100N horizontal were analyzed by MSC Nastran FEM Package. according to the result of this study the occlusal force distribution depends on the structure of cancellus bone and for further information on the occlusal force distribution on the tooth and the surrounding structure requires further studies on cancellus bone structure. CEJ of all model show the highest peak and region whice meet teeth and bone show second high peak. Original model and cortical bone add model show different stress distribution. Stress distribution changed according to bone structures and densities.

SA 516-70 압력용기용강의 저온피로 크랙전파 특성에 관한 연구 (Fatigue Crack Propagation Characteristics in SA 516-70 Steel for Pressure Vessels at Low Temperature)

  • 박경동;차성수
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.51-56
    • /
    • 1999
  • Fatigue crack propagation rates and characteristics of the SA516-70 steel which is used for the low temperature pressure vessels, were studied in the room temperature of $10^{\circ}C$ and low temperature ranges of $-10^{\circ}C,\;-30^{\circ}C,\;-50^{\circ}C,\;and\;-70^{\circ}C$ with stress ratio of R=0.05. The obtained experimental results are as follows; 1) In the logarithmic relationship between the fatigue crack propagation rate(da/dN) and stress intensity factor K, the linear relationship was obtained up to da/dN > $8{\times}10^3$ mm/cycle in the same of room temperature, but in low temperature case, the relationship was extended to the range of low crack propagation rate. 2) The lower limit stress intensity factor of SA516-70 ${\Delta}K_{th}\;was\;23MPa\sqrt{m}$ and in the case of low temperature $-50^{\circ}C\;and\;-70^{\circ}C$, the crack propagation rate da/dN which showed a linear relation, reached rapidly to the ${\Delta}K_{th}$. As the results, the crack propagation rates of $-50^{\circ}C\;and\;-70^{\circ}C$ were lower than that of room temperature and according to the testing temperature the rates were decreased rapidly to the ${\Delta}K_{th}$. 3) On the relationship between the stress intensity factor ${\Delta}K$ and the track propagation cycle, the stress intensity factors of low cycle region was rapidly increased at low temperature, but ${\Delta}K$ was increased rapidly at room temperature of high cycle. 4) On the relationship between the fatigue crack propagation rate and cycle, the fatigue crack propagation rate showed higher gradient in the room temperature than the low temperature due to the increment in ductility at low temperature.

  • PDF

순간중심 고정식 및 이동식 인공디스크 적용에 대한 유한요소 모델을 이용한 생체역학적 분석 (Biomechanical Analysis of the Implanted Constrained and Unconstrained ICR Types of Artificial Disc using FE Model)

  • 윤상석;정상기;김영은
    • 한국정밀공학회지
    • /
    • 제23권4호
    • /
    • pp.176-182
    • /
    • 2006
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical changes with its implantation were rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, a nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Biomechanical analysis was performed for two different types of artificial disc having constrained and unconstrained instant center of rotation(ICR), ProDisc and SB Charite III model. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, forces on the spinal ligaments and facet joint, and stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400N were compared. The implanted model showed increased flexion-extension range of motion compared to that of intact model. Under 6Nm moment, the range of motion were 140%, 170% and 200% of intact in SB Charite III model and 133%, 137%, and 138% in ProDisc model. The increased stress distribution on vertebral endplate for implanted cases could be able to explain the heterotopic ossification around vertebral body in clinical observation. As a result of this study, it is obvious that implanted segment with artificial disc suffers from increased motion and stress that can result in accelerated degenerated change of surrounding structure. Unconstrained ICR model showed increased in motion but less stress in the implanted segment than constrained model.

인장법에 의한 박판 판계 용접부의 잔류 응력 거동 특성에 관한 연구 (A Study on the Behavior Characteristics of Residual Stress of the Thin Butt Weldment by Mechanical Tensioning Method)

  • 김하근;김경규;신상범
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.57-57
    • /
    • 2010
  • For thin panel welded structure, the various welding distortions were found due to the low resistance against welding deformation. Especially, buckling distortion induced in the thin panel welded structure produce severe problems related to cost in production stage and safety in service life. So, many researches including mechanical and thermal tensioning method for preventing the occurrence of buckling distortion in the production stage have been performed. The purpose of this study is to identify the behavior of longitudinal residual stress at the SA butt weldment with thin plate of 6mm thickness under tension load by 3 dimensional FEA. For it, mesh design for 3D FEA was constructed with 20 nodes brick element for butt weldment and 8 nodes shell element for base metal. According to FEA results, the longitudinal compressive strain inducing tensile residual stress at the butt weldment decreased. It was because the compressive thermal strain in way of weldment was reduced by tension load. The control effect of residual stress increased with an increase in tension load. So, if the amount of tension load applied to the weldment exceeds 1.5 times of longitudinal shrinkage force, the amount of longitudinal residual stress decreased below the critical value inducing the buckling distortion at the SA butt weldment. Its validity was verified by experiment.

  • PDF

ASTM 516-60 강의 저온피로 크랙전파 특성에 관한 연구 (Fatigue Crack Propagation Characteristics in ASTM 516/60 Steel at Low Temperature)

  • 박경동;김정호
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.240-245
    • /
    • 2000
  • Fatigue crack propagation rates and characteristics of the SA516-60 steel which is used for the low temperature pressure vessels, were studied in the room temperature of $25^{\circ}C$ and low temperature ranges of $10^{\circ}C,\; -10^{\circ}C,\; -30^{\circ}C,\; -50^{\circ}C, \;and\; -70^{\circ}C4 with stress ratio of R=0.05. The obtained experimental results are as follows; 1) In the logarithmic relationship between the fatigue crack propagation rate(da/dN) and stress intensity factor K, the linear relationship was obtained up to da/dN 〉$8\times10^{-3}$/mm/cycle in the same of room temperature, but in low temperature case, the relationship was extended to the range of crack propagation rate. 2) The lower limit stress intensity factor of SA516-60 $\DeltaK_{th}$ was 15.8MPa and in the case of low temperature $-50^{\circ}C\; and\; -70^{\circ}C$, the crack propagation rate da/dN which showed a linear relation, reached rapidly to the $\DeltaK_{th}$/. As the results, the crack propagation rates of $-50^{\circ}C\; and\; -70^{\circ}C$ were lower than that of room temperature and according to the testing temperature the rates were decreased rapidly to the $\DeltaK_{th}$/. 3) On the relationship between the stress intensity factor $\DeltaK$ and the crack propagation cycle, the stress intensity factors of low cycle region was rapidly increased at low temperature, but $\DeltaK$ was increased rapidly at room temperature of high cycle. 4) On the relationship between the fatigue crack propagation rate and cycle, the fatigue crack propagation rate showed higher gradient in the room temperature than the low temperature due to the increment in ductility at low temperature.

  • PDF

저속 충격하에서의 금속복합재료의 동적 특성 (Dynamic Behaviors of Metal Matrix Composites in Low Velocity Impact)

  • 남현욱;;;한경섭
    • Composites Research
    • /
    • 제12권1호
    • /
    • pp.68-75
    • /
    • 1999
  • 본 연구에서는 저속 충격에서 충격 속도에 따른 금속복합재료의 동적 거동을 연구하였다. 시험에 사용된 재료는 모재로 AC8A와 보강재로 알루미나($Al_2O_3$)와 탄소를 사용하였으며 용탕 주조법을 이용하여 금속복합재료를 제조하였다. 금속복합재료에는 15%의 부피분율을 가진 알루미나 예비성형체와 알루미나와 탄소를 각각 12%와 3% 사용한 혼합 에비성형체가 사용되었다. 제조된 금속복합재료는 인장 시험과 진동 시험을 통해 인장 강도와 탄성계수를 구하였으며, 저주파 여파기(low pass filter)와 계장화 충격 시험기를 이용하여 충격 속도에 따른 금속복합재료의 충격 거동을 연구하였다. 저주파 여파기를 이용함으로써 충격 속도에 관계없이 안정적인 실험치를 확보할 수 있었다. 충격 속도의 증가에 따라 모재와 금속복합재료의 충격에너지는 증가하였으나, 동적인성치는 일정한 값을 보였다. 충격 속도가 증가할수록 충격에너지 중 균열전파에너지의 향상이 두드러졌으며, 재료의 변형량이 증가하였다. 충격에너지 중 균열개시에너지와 동적파괴인성치의 관계를 설명하기 위하여 변형율 에너지와 노치에서의 응력 분포를 이용하여 간단한 모델을 제시하였으며, 이로부터 균열개시에너지는 동적 파괴 인성치의 자승에 비례하고 탄성계수에 반비례하는 것을 보였다.

  • PDF

자동차용 PCV밸브내 유통특성에 의한 밸브응력 및 변형에 미치는 입출구 차압의 영향 (The Effect of In-Outlet Differential Pressure on a Valve Body Stress and Deformation by the Blow-by Gas Flow Characteristic in the PCV valve for Automobile)

  • 권오헌;이연원;송상민;이종훈;강지웅
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.36-41
    • /
    • 2005
  • PCV(Positive Crankcase Ventilation) valve acts as a flow control valve to get a re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. The blow-by gas of the crankcase should be eliminated or taken properly because it cause corrosion to critical parts, and contributes to increase crankcase pressure that can cause a drop in efficiency. The excessive stress and strain on the PCV valve that remove these harmful gas would be bring the difficult on the flow rate control and failure of the valve. Those condition inevitably induce the accident. Therefore, this study purpose is FEM evaluation of the stresses and deformation in the X3 PCV model according to the change of the differential pressure between inlet and outlet. From results, the maximum equivalent stresses increased linearly according to the increase of the differential pressure at the about 50mm from the inlet position and were under the yield strength of the valve. And the deformations were relatively small regardless of the in-outlet differential pressure variation.

접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구 (Contact non-linear finite element model analysis of initial stability of mini implant)

  • 윤현주;정의원;이종석;김창성;김정문;조규성;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

시멘트-대퇴Stem 경계면 해리가 골-시멘트 경계면에 미치는 응력 분석 -3차원 비선형 Finite Element Analysis- (Stress analysis of the effect of debonding of cement-femoral stem interface to the bone-cement interface -A three-dimensional Finite Element Analysis-)

  • 김성곤
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.337-346
    • /
    • 1996
  • Debonding of cement-femoral stem interface has been suggested as a initial focus of loosening mechanism in many previous studies of cemented total hip replacement. The purpose of this study was to investigate the effect of debonding of cement-femoral stem interface to the bone-cement interface by using three-dimensional non-liner finite element analysis. Three cases of partial debonded, full debonded, full bonded cement-bone interface were modelled with partial bonding of distal 70mm from the tip of femoral stem. Each situation was studied under loading stimulating one-leg stanced gait of 68kg patient. The results showed that under partial and full debonded cement-stem interface condition the peak von Mises stress(3.1 MPa) were observed at the cement of bone-cement interface just under the calcar of proximal medial of femur, and sudden high peak stresses(3.5MPa) were developed at the distal tip of femoral stem at the lateral bone-cement interface in all 3 cases of bonding. The stresses were transfered very little to the cement of upper lateral bone-cement interface in partial and full debonded cases. Thus, once partial or full debonded cement-femoral stem interface occured, 3 times higher stress concentration were developed on the cement of proximal medial bone-cement interface than full bonded interface, and these could cause loosening of cemented total hip replacement. Clinically, preservation of more rigid cement-femoral stem interface may be important factor to prevent loosening of femoral stem.

  • PDF