• Title/Summary/Keyword: 휨 시험체

Search Result 288, Processing Time 0.03 seconds

A Study on the Flexural Strength Capacity of Wall Stud Assembly (경량형강 스터드 벽체의 휨강도에 관한 연구)

  • Kwon, Young Bong;Chung, Hyun Seok;Kim, Gap Deuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2003
  • An investigation on the structural behavior of cold-formed steel lipped C-section stud for interior walls or partitions was carried out. This experimental research was carried out to study the ultimate and service load capacity of stud assemblies that are subjected to lateral loads. Each test specimen consisted of three or four lipped C-section studs and two C-section tracks that restrained both ends. The major factors considered in this experiment were the perforation on the web, the connection of the bridge channel and the special clip. The effect of the plaster board and the ply wood, which were attached to the tension flange on the flexural strength, was also investigated. Thereafter, the test strength capacities were compared with the nominal strength, based on the AISI Specifications (1996).

A Study on the Fire Resistance Capacity of Slimfloor Beam with Asymmetric H Beam (비대칭 H형강을 사용한 슬림플로어 보의 내화성능에 관한 연구)

  • Han, Sang Hoon;Choi, Seng Kwan;Kim, Hee Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • This paper is a pilot study regarding an experimental and parametric study to investigate the structural behavior of slimfloor beam(ASB) in fire. The objective of this research is to obtain the rational fire resistance design method through understanding the structural behavior of composite members in fire. The flexural capacity of slimfloor section under various thermal conditions is examined on a basis of the strength retention of the materials at elevated temperatures and full bonding assumption. The effect of web thickness and ASB depth to the moment capacity in fire is also examined.

Evaluation Method of Self-healing Performance of Cement Composites (시멘트 복합체의 자기치유 성능평가 방법)

  • Lee, Kwang-Myong;Kim, Hyung-Suk;Min, Kyung-Sung;Choi, Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.134-142
    • /
    • 2020
  • In this study, in order to evaluate the self-healing performance of cement composites the self-healing test method and the analysis method were suggested by applying constant water head permeability test, chloride migration test and repeated bending test. The method of making a cracked specimen and controlling crack width are also proposed. Constant head water permeability test can evaluate the healing performance by using the decreasing rate of water flow passing through the crack zone of a specimen. Furthermore, the equivalent crack width can be used to intuitively investigate the healing effect with healing period. The chloride migration test can evaluate the healing rate by the decreasing rate of the diffusion coefficient obtained by ASTM C 1202. Mechanical healing performance can be evaluated using ISR and IDR estimated from load vs. CMOD relationship graph obtained through the repeated bending test. Finally, the applicability of proposed self-healing evaluation methods was examined by testing mortar specimens with or without self-healing agents.

Experimental Study on Bending and Shear Behavior of SC Structures under Out of Plane Load (면외하중을 받는 보형 SC구조 시험체의 휨 및 전단특성에 관한 실험적 연구-시험방법을 중심으로-)

  • Park, Dong-Su;Jeoung, Won-Seoup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.65-68
    • /
    • 2008
  • This is an experimental study on the out of plane load behavior of SC (Steel Plate Concrete) wall module under bending and shear loading. 4 tests were conducted to verify structural performance according to rib reinforcement ratio, stud reinforcement ratio and shear reinforcement ratio. On the basis of test results, it is found that rib reinforcement ratio is a main factor of flexural strength of SC structures.

  • PDF

Effect of Cutting Off Tension Bars in R/C Beams On the Full Scale and Model Specimens (철근콘트리트 보에서 체단된 철근의 효과에 관한 연구 실물 및 축소모형실험을 중심으로)

  • 이리형;최창식;임재형
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.1
    • /
    • pp.79-90
    • /
    • 1990
  • The purpose of this paper is to study on the effect of cutting off tension bars in reinforced concrete beams. that is, the ultimate strength, the failure mode and thl} tension stress distribution through the span. To achieve this purpose, a full-scale frame and seven small scale model beams (five rectangular and two T-section beams) were tested. The four main model specimens and two speciml}ns without cutting off tension bars 1,'{ere analyzed as plane stmss element with package program ADINA. As a result of test and analysis, the shorter' distance bet ween the reaction point and the cutting off point, the higher the ultimate strength of a bl}am will be when other physical properties are equal.

Evaluation of the Performance and Moisture Retaining Ability in Semi-Rigid Pavement (반강성포장의 성능 및 보수성 평가)

  • Park, Tae-Soon
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.69-79
    • /
    • 2008
  • This study presents the test results on the performance and the moisture retaining ability of semi rigid pavement using the moisture retaining grouting. The two kinds of the grouting materials were used for the Laboratory tests. The method of the tests includes the compression(3 hours and 7 days) and flexural strength(7 days) varying the P lot flow values. The test results show that the variation of the P lot value has no great effects on the strength, however, the different strength was found as the different grouting materials were used. The performance of the semi rigid pavement was evaluated varying the air void ration of the base asphalt pavement. The test results show that the flexural strength of the semi rigid pavement increases with increasing the air void of the base asphalt pavement so that the flexural strength of the semi rigid asphalt pavement can be effected by the air void of the base asphalt pavement. The moisture retaining tests were conducted and compared in the field the comparisons were made with the dense grade asphalt pavement and the semi rigid asphalt pavement with and without spraying the water. The difference of the temperature of the semi rigid pavement with the spraying water has recorded $11^{\circ}C$ when it compared with the dense grade asphalt pavement and $4^{\circ}C$, when it compared with the semi rigid pavement without the spraying the water. It can be seen that decrease the temperature of the pavement by the moisture retaining ability from the semi rigid pavement.

  • PDF

Evaluation of the Flexural Behavior of Composite Beam with Tunnel Steel Rib Support Using Circular Concrete Filled Steel Tube (콘크리트 충전 원형 강관을 이용한 터널강지보 합성부재의 휨거동 평가)

  • Ma, Sang Joon;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • The purpose of this study is to evaluate the strength and behavior of the composite member in case of concrete filled steel tube embedded in concrete for application concrete filled steel tube to steel rib support in tunnel. A total of six beam specimens were prepared for steel tube in-filled with plain concrete and aerated concrete, and static bending tests were performed. As a result, the member of concrete steel tube embedded with plain concrete showed higher strength than those with aerated concrete. However, it was found that the flexural strength of member with reinforcing bar around the steel tube is more influenced by the amount of the reinforcing bar than the type of the filled concrete.

Performance of Geogrids for Retarding Reflection Crack of Asphalt Overlay Pavement (아스팔트 덧씌우기의 반사균열 지연을 위한 지오그리드의 적용성 연구)

  • Kim, Kwang-Woo;Doh, Young-Soo;Kim, Bun-Chang;Lee, Moon-Sup
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.1-12
    • /
    • 2005
  • This study was conducted to evaluate effect of geogrid and fabric, which are used underneath the overlaid asphalt pavement for retarding reflection cracking by simulated laboratory test. In this study, an interlayer at the interface between old concrete pavement surface and overlaid asphalt mixture, and polymer-modifier were used as an effort of retarding reflection crack initiation and for strengthening mixture. Five products were used in preparation of asphalt concrete beam specimen which was tack coated on top of jointed concrete block. Simulated Mode I and II fracture test were conducted under wheel loading and results were compared among those products. From the test results, several material and reinforcement combinations were observed to have a significant retardation effect against reflection cracking. The most effectively strengthened pavement against reflection cracking was found to be the LDPE-modifier asphalt mixture with a grid reinforcement at the bottom.

  • PDF

Evaluation of the Properties of Absorbent-Pervious Cement Mortar (보투수성 시멘트 모르타르의 성능평가)

  • Lho, Byeong Cheol;Joo, Myung Ki;Choi, Jong Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.288-295
    • /
    • 2011
  • The objective of this study is to develop a proper absorbent-pervious pavement. By using single graded aggregates and SAP, permeability and water absorbability of absorbent-pervious pavement are improved, and also temperature reducing effect is found out. And several tests such as compressive and flexural strength tests, and permeability/water absorption tests of absorbent-pervious pavement are carried out to verify these kind of effects. The compressive and flexural strengths are increased according to decrease of single graded aggregate size, and increase of SAP content. And the volume of water retention and absorbability are increased according to the increase of SAP content and these are also increased in small size of single graded aggregate. And about $20^{\circ}C$ of difference is observed in surface temperature between normal asphalt pavement and absorbent-pervious pavement.

Flexural Behavior of High-Strength Reinforced Concrete Beam with Recycled Aggregate Strengthened by FRP Plate (FRP로 보강된 순환골재 고강도 철근콘크리트 보의 휨거동)

  • Hong, Seong-Uk;Lee, Seung-Ho;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.126-132
    • /
    • 2018
  • As means to increase the use of concrete with recycled coarse aggregate (RCA), this study aims to evaluate the applicability for flexural strengthening of reinforced concrete beam with high-strength concretes and RCA on which FRP plates, used for repair and strengthening of old and low-durability reinforced concrete structures, is applied. In order to increase the adhesive force of epoxy and FRP plate, FRP plate was installed according to Near-Surface-Mounted (NSM) method. 12 specimens were manufactured using substitution rate of RCA (30%), concrete strengths (40MPa, 60MPa), diameters of deformed bar (D10, D13), and types of FRP plate (AFRP, CFRP) as variables to analyse flexural performance according to FRP plate and substitution rate of recycled aggregate. As a result, in all specimens, specimens strengthened by FRP plate showed a maximum of 17% increase in performance compared to specimens without FRP plate and strengthening performance of CFRP was found to be higher than AFRP. When modulus of rupture was used, the value of cracking moment was similar to that of the reference equation. As bending moment of some specimens strengthened by FRP plate failed to satisfy the criteria of KCI 2012 and ACI 440-2R, additional experiment is deemed as necessary.