• Title/Summary/Keyword: 회생인버터

Search Result 81, Processing Time 0.027 seconds

Development of Regenerative Inverter for Electric Railway Using Space Vector PWM (SVPWM을 이용한 전기철도용 회생 인버터 개발)

  • 백병산;정문구;김태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • As a device that returns surplus energy, regenerated from trains to d.c. source, to a.c. system and reuses it, the thyristor Inverter has been widely used. Because the conventional thyristor inverter is a unidirectional phase-controlled device, it Is Impossible to control the power factor of its output. Moreover, harmonics emission is high and it needs to take a additional filter. In this paper, to solve the problems stated above, the inverter, which can control real and reactive power by adopting IGBT modules as switching elements and being controlled by means of space vector PWM, is developed. Considering high economical efficiency and reliability in order to apply to the system for commercial use, the developed inverter is equipped with fully digital control system and low pass filter, and reduces harmonics and has compact size. The detail description about the developed inverter is stated in various respects: design criteria, technical description, power circuits, control techniques, the developed system, test results, etc.

A Study on the Deceleration Techniques in an Industrial drive (산업용 인버터의 감속 기법에 관한 연구)

  • Kim, Jung Han;Jeon, Jong Wook;Kim, Jeong Bin
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.69-70
    • /
    • 2012
  • 유도 전동기를 제어하기 위한 일반적인 상용인버터는 다이오드 정류부, 평활용 Cap부, 인버터부로 구성된다. 시스템의 설계에 따라 가감속을 선정 할 수 있으며 산업현장에서는 부하의 관성이 큰 경우에 빠른 감속이 요구되는 경우가 있다. 상용 인버터는 감속 시 소비되는 에너지 외에 회생에 사용되며 회생 에너지에 비례하여 DC 링크 전압이 커지는데 이는 인버터의 소손 원인이 된다. DB유닛으로 이 문제를 해결해 줄 수 있지만 가격적인 부담을 가지고 있다. 부하의 관성이 크고 감속시간이 짧은 경우 DC 링크 과전압 방지를 위해 모터 출력의 정격에 맞는 출력지령을 내보내는 기술에 경제형 상용 인버터 시스템에 맞게 지령을 조정하는 부분을 추가하여 본 논문의 감속기법을 제안하였다. 이 방법은 DB유닛을 사용하지 않았으며, 실험을 통해 검증하였다.

  • PDF

Development of Regeneration Inverter using 3-Level Inverter (3레벨 인버터를 이용한 직류전력 회생인버터 개발)

  • 김상균;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1007-1012
    • /
    • 2002
  • In this paper, a regeneration inverter is proposed using 3-level inverter. Electric regeneration means regeneration brake in electric railway vehicles. Induction motors, generally used with railway vehicles, convert the electric energy to the movement energy when vehicle is running. When the vehicle stop, the induction motor convert the movement energy to the electric energy. Usually, this energy is used with another running vehicle in the same section. If there is no vehicle around when the regeneration is occurred, regeneration energy is consumed by heat energy with resistors. The proposed inverter is capable of reuse this regeneration energy in another place.

  • PDF

Regenerative Power Drive of a Induction Motor Based the Acceleration Method (FAM 법에 의한 유도형 서보 전동기의 전력회생 구동)

  • Hong, Jeng-Pyo;Nam, Jing-Rak;Kim, Jong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.202-205
    • /
    • 2005
  • 본 연구는 스파이랄 벡터에 기초한 유도전동기 모델의 해석을 나타내고 이 해에 기초한 자계가속법(Field Acceleration Method)에 의해 순시 토크 제어와 회생전력 해석을 나타내었다. 전압지령형의 PWM제어에서 전압형 인버터에 의해 전동기가 동작할 때 전력회생이 수식으로 해석 되었다. 전압지령형의 전압 PWM 인버터에 의한 유도 전동기의 속도 서보시스템을 설계하고 이 속도제어 시스템을 이용해 가감속시의 소비(회생)전력을 측정하여 실제 시스템에서 전력 절약정도를 검토하였다. FAM법에 의한 실험을 행하고 유효성을 확인하였다. 고정자 저항의 측정오차나 변동은 여자전압에 맥동이 생겨 출력 토크에 영향이 나타는 것을 알 수 있었다.

  • PDF

Measurement and Analysis of Regenerative Energy in DC 1500V Electric Traction Substation (직류 1500V 전철변전소의 회생전력량 측정 및 분석)

  • Bae, Chang-Han;Jang, Dong-Uk;Kim, Ju-Rak;Han, Moon-Seub;Kim, Yong-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.717-722
    • /
    • 2007
  • Most of DC 1500V electric railway substations have adopted diode rectifiers to supply stable DC power. However, the diode rectifiers operate in the first quadrant of the voltage-current plane and thus need regenerative inverters which transfer the surplus regenerative power caused by regenerative braking of electric train sets into the grid. In order to select the proper capacity and installation position of regenerative inverter, it needs to investigate the consumed and regenerative energy of the electric traction substations in advance. This paper presents an analysis of regenerative energy in two substations operating in Seoul Seolleung and Kwangju Yangdong substations. DC line voltage and feeder currents are measured for a day to calculate consumed and regenerative power far four feeders. We calculated an amount of regenerative energy consumed in other feeders and estimated the cost reduction in energy consumption due to the reuse of regenerative energy

Instant Power Failure Response Algorithm of H-bridge Multilevel Inverter (H-브리지 멀티레벨 인버터의 순간정전 대응 알고리즘)

  • Won, Je-Hyuk;Lee, Hyun-Won
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.377-378
    • /
    • 2014
  • 본 논문에서는 H-브리지 멀티레벨 인버터의 순간정전 발생 대응 알고리즘을 제안한다. 순간정전 발생 시 인버터를 정지시키면 연속적인 운전을 요구하는 부하의 경우 재정적인 손해로 이어지므로 이에 대응 하는 알고리즘이 필요하다. 순간정전 시 감소하는 각 셀의 직류전압을 회생에너지를 통하여 확보한다. 또한 순간정전 대응시간을 초과하는 경우에는 재기동 기능으로 절체함으로서 제품에 보다 효과적으로 적용하고자 한다. 본 논문에서 제안한 제어 알고리즘을 실험을 통해 검증하였으며, 제품의 상용화를 고려하여 재기동 기능과 연계하여 실험하였다.

  • PDF

Ride-through control method for instantaneous power interruption in V/f controlled drive system (순간 정전 시 V/f 제어의 Ride Through 운전)

  • Choi, Seung-Cheol;Lee, Hak-Jun;Hong, Chanook;Lee, Sang-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.558-560
    • /
    • 2019
  • 범용 인버터는 계통 전원의 전압 강하 또는 정전 발생 시, 정류기의 직류단 전압이 감소하여 인버터 고장(fault)이 발생한다. 보호 동작으로서 인버터는 일시적으로 전원 공급이 이루어 지지 않는 상태에서 제어 기능 및 관리가 이루어 질 수 있도록 Ride-Through 운전을 수행한다. 고장 발생 없이 제어 시스템 상태를 유지하여 전원 복구 후, 빠른 재기동이 가능하다. 본 논문에서 V/f 제어를 사용하는 범용 인버터를 고려한 Ride-Through 방법으로 KEB(Kinetic Energy Backup) 운전을 제안한다. KEB 운전은 순시 정전에 의한 인버터 고장 방지를 위해 요구되는 에너지를 계산하고 슬립 주파수를 조절하여 회생 운전을 통해 인버터의 직류단 전압을 일정하게 유지한다. 제안한 방법은 실험을 통해 유효성을 검증한다.

  • PDF

The Inverter Control Method Using The Voltage sag compensation algorithm (순간전압강하 보상 알고리즘을 이용한 인버터 제어에 관한 연구)

  • Yun, Hong-Min;Kim, Yong;Yong, Bae-Jin;Cho, Gyu-Man;Eom, Tae-Min
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1169-1170
    • /
    • 2011
  • 일반적으로 유도전동기를 구동시키기 위한 범용 인버터는 입력 전원에 정전이 발생하였을 경우 부하에 따라 수십 msec안에 저전압 트립이 발생하여 PWM 출력이 차단된다. 부하의 관성이 큰 경우 전원이 복구 되었을 때, 기존의 속도로 정상 가속하기 위해서는 부하가 완전히 멈춘 후 인버터를 구동시키고, 다시 큰 관성의 부하를 가속하는데 긴 시간이 필요하다. 본 논문은 유도전동기를 V/f 제어방법으로 운전하고 있는중에 정전이 발생했을 때 인버터의 출력을 차단하지 않고 연속적인 제어를 행하는 순간정전 보상 알고리즘방법으로서 부하의 관성 에너지를 인버터 직류단에 회생시키도록 출력 주파수를 제어하는 방법을 제안하고 실험을 통해 이를 검증하였다.

  • PDF

Power Loss Ride-Through of Industrial Inverter (산업용 인버터의 Power Loss Ride-Through)

  • Jeon, M.R.;Kim, K.Y.;Kim, J.B.;Kim, K.S.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.309-310
    • /
    • 2010
  • 일반적으로 유도전동기를 구동시키기 위한 범용 인버터는 입력 전원에 정전이 발생하였을 경우 부하에 따라 수msec에서 수백msec 안에 저전압 트립이 발생하여 PWM 출력이 차단된다. 부하의 관성이 큰 경우 전원이 복구 되었을 때, 기존의 속도로 제어되기 위해서는 부하가 완전히 멈춘 후 인버터를 구동시키고, 다시 큰 관성의 부하를 가속하는데 긴 시간이 필요하다. 본 논문은 유도전동기를 V/f 제어방법으로 운전할 경우 정전이 발생했을 때 인버터의 출력을 차단하지 않고 연속적인 제어를 행하는 Ride-Through 방법으로서 부하의 관성 에너지를 인버터 직류단에 회생시키도록 출력 주파수를 제어하는 방법을 제안하고 실험을 통해 이를 검증하였다.

  • PDF

Research and Design of Inverter for Controlling A Large Size Plasma Sign Board (대면적 플라즈마 사인 보드의 제어를 위한 인버터 설계 및 연구)

  • Lee, Jae-Deog;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.41-42
    • /
    • 2010
  • 본 논문에서는 대면적 플라즈마 사인 보드 제어를 위한 저소비 전력용 인버터를 개발하였다. 이 인버터는 215*86mm 사이즈로 인가전압 220V, 출력전압 1200V, 스위칭 주파수 20KHz, 소비전력 50W 급인 인버터를 역률개선회로 PFC(Power Factor Correction)를 적용하여 리플을 줄이고 안정적인 전압 공급, 전체 전류 정격감소, 회생전압 상승분 억제, 유니버설 입력범위에서 동작 가능하게 만들었다. 고전압트랜스를 4개를 집적화 하였으며 전력 소비 전류가 감소되면서 온도가 상승되는 것을 막을 수 있었고 전자파도 줄일 수 있음을 보였다.

  • PDF