• Title/Summary/Keyword: 환산인자

Search Result 111, Processing Time 0.026 seconds

Conversion Factors for Calibration of Personnel Dosimeters (개인선량계 교정을 위한 환산인자 계산)

  • Lee, Won-Koo;Lee, Tae-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 1991
  • MCNP code was used to calculate conversion factor H(d)ma at the depths of 0.07 and 10mm within a water phantom recommended by IAEA and within a PMMA phantom required by the US dosimeter proficiency testing programmes. The calculations were performed for an expanded parrallel beam of monoenergetic photons of perpendicular incidence on one faces of the phantom. The results can be used as conversion factor in calibrating individual dosemeters in terms of the dose equivalent quantities defined directly in the phantom.

  • PDF

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF

A New Approach for the Calculation of Neutron Dose Equivalent Conversion Coefficients for PMMA Slab Phantom (PMMA 평판형 팬텀에서의 중성자 선량당량 환산계수의 새로운 계산법)

  • Kim, Jong-Kyung;Kim, Jong-Oh
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.297-311
    • /
    • 1996
  • ANSI decided PMMA slab phantom as a calibration phantom and introduced a conversion coefficient calculation method for it. For photon, the conversion coefficient can be obtained by using backscatter factor and conversion coefficient of the ICRU tissue cube and backscatter factor of the PMMA slab. For neutron, however, the ANSI has not introduced any conversion coefficient calculation method for the PMMA slab. In this work, the ANSI method for the photon conversion coefficient calculation was applied to the neutron conversion coefficient calculation of the PMMA slab. Quality weighted tissue kerma of neutron was applied to calculate the backscatter factors on the ICRU cube and the PMMA slab. The dose conversion coefficient of the ICRU cube was also calculated by using MCNP code. Then, the dose conversion coefficient of the PMMA slab was calculated from two backscatter factors and the dose conversion coefficient of the ICRU cube. The discrepancies of the dose conversion coefficients of the PMMA slab and the ICRU cube were less than 10% except 1eV(20%), 1keV(17%), and 4 MeV(16%).

  • PDF

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors

  • Kwon, Seog-Guen;Kim, Kyung-Eung;Ha, Chung-Woo;Moon, Philip S.;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.171-179
    • /
    • 1980
  • This paper presentss flux-to-dose conversion factors for neutrons and gamma-rays based on the concept of the maximum absorbed dose. Neutron flux-to-does-rate conversion factors for energies from 2.5$\times$10$^{-8}$ to 20 MeV are presented while the conversion factors for gamma-rays are given in the energy range of 0.01 to 15MeV. Flux-to-does-rate conversion factors, which were calculated under the assumption that the radiation energy distribution has nonlinearity in phantom, are different from those values obtained by monoenergetic radiation. Especially, these values obtained here were determined for the cross section libray such as DLC-23, DLC-27, and DLC-31. The flux-to-dose-rate conversion factors obtained in this work are in a good agreement with the values presented by American National Standard Institute (ANSI) N666. These results are used to calculate the dose rate distribution of neutron and gamma-ray in any radiation fields, and will be useful for the radiation shielding analysis, radiation protection and radiation dosimetry concerned with problems of continuous energy distribution.

  • PDF

Dose rate conversion factor for soil by the beta-rays and gamma-rays from 238,235U, 232Th and 40K (238,235U, 232Th과 40K의 베타선 및 감마선에 의한 토양의 흡수선량 환산 인자)

  • Kim, Gi-Dong;Eum, Chul-Hun;Bang, Jun-Hwan
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.460-467
    • /
    • 2007
  • Dose rate conversion factor was calculated to estimate the absorbed effective annual doses for soils for the beta-rays and gamma-rays, which were emitted from $^{238,235}U$, $^{232}Th$, and $^{40}K$ isotopes. The most recent data of the emitted energies per decay, half-lifes, and branching ratios, which were obtained from National Nuclear Data Center, were used. When this factor and the effective annual doses for the beta-rays and the gamma-rays of natural radioisotopes were compared with those of Aitken, these of $^{238}U$, $^{232}Th$ and $^{40}K$ are estimated to have good agreements but a large difference is shown in this for $^{235}U$. Through the calculations of effective annual doses by using these factor and the measurements of gamma-ray spectra for soils, which were extracted from prehistoric remains (Mansuri) on Osong, Chungchengbuk-do, The annual effective doses were obtained to be 3.8~5.9 mGy/yr. Also, when these doses including decay elements upper Rn were compared with those on all isotopes, the differences within 9~30 % were obtained. The analysis method of the annual effective doses for the beta-rays and the gamma-rays of the natural isotopes of soils was established by this dose rate conversion factor.

Calculations of ISO Narrow and ANSI X-Ray Spectra, Their Average Energies and Conversion Coefficients (ISO Narrow Series및 ANSI의 X선 스펙트럼, 평균에너지 및 선량환산인자의 이론적 계산)

  • Kim, Jang-Lyul;Kim, Bong-Whan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 1995
  • In spite of the prescriptions on the reference X-ray fields given by the International Organization of Strandard(ISO) and American National Standard Institute(ANSI), the measurement of X-ray spectrum is not only time consuming but very difficult, paticularly when significant corrections have to be applied to the measured pulse-height distributions of the observed spectra. This paper describes the calculation method of ISO Narrow Series and ANSI X-ray filtered radiations by theoretical model which is modified framer's theory by target attenuation and backscatter correction. The X-ray spectra, average energies and conversion coefficients are calculated and compared with those obtained using the spectra prescribed by ISO and AMSI to assure good agreement.

  • PDF

Method for Determining Transportation Grade for HIC Containing Spent Resin Using Radioactivity Analysis (방사성페기물 핵종분석 결과를 사용한 폐수지의 운반물등급 분류 방법)

  • Kim, Tae-Wook;Choi, Ki-Seop;Kang, Ki-Doo;Ha, Jong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • In order to transport spent resin in a high integrated container made of high density polyethylene, a method for determining transportation grade by radioactivity analysis was developed. Ratios of radioisotopes in spent resin were derived from radioactivity analysis on spent resin. Associated curie-to-dose factors were determined to estimate radioisotope inventory from surface dose rates of spent resin. From the results, Activity limit of type A package was derived to be 1.19 TBq for HIC, and the corresponding surface dose rate was found to be 124.2 mSv/h.

  • PDF

말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산

  • 김광표;윤석철;윤여창;김종수;홍종숙
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.57-62
    • /
    • 1996
  • ANSI N13.32는 손목팬텀과 손가락팬텀에서 말단선량계의 특성조사를 위하여 방향의존성인자를 선량계의 성능평가에 적용하도록 권고하고 있다. 본 연구에서는 말단선량의 정확한 선량평가를 위하여 ANSI N13.32에 제안된 팬텀과 동일하게 모사하고 그 팬텀내의 7mg/$\textrm{cm}^2$ 깊이에서 단일에너지를 가진 광자의 선량당량환산인자 및 방향의존성인자를 MCNP 전산코드를 사용함으로써 계산하였다. 또한 본 연구의 최종목적인 ISO Narrow X-선 빔에 의해 조사된 손가락팬텀에서 선량당량환산인자 및 방향의존성인자를 도출하였다. 전산 수행한 결과 낮은 전압에서 발생된 X-선 빔인 경우, 팬텀의 주축을 따라 수평회전각이 증가할수록 방향의존성인자가 크게 감소하며, 한편 높은 전압에서 생성된 X-선 빔인 경우, 수평회전각이 증가할수록 방향의존성인자간 처음에는 근소하게 감소하지만 90。까지는 증가하고 있음을 알 수 있었다.

  • PDF

A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter (말단선량계의 광자선량당량환산인자에 대한 이론적 계산)

  • Kim, Kwang-Pyo;Lee, Won-Keun;Kim, Jong-Su;Yoon, Yeo-Chang;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • In this study, the theoretical calculation of the air kerma-to-dose equivalent conversion factors was performed with a Monte Carlo N-Particle transport code for the two types of extremity phantom of the ANSI and the KAERI, respectively. Considering the distribution of absorbed dose due to the interaction of homogeneous Parallel broad beam of monoenergetic primary photons in the range between 15keV and 1.5MeV, the air kerma-to-dose equivalent conversion factors based on the kerma approximation were calculated. It is showed that all the theoretical conversion factors of the two types of the extremity phantom for the ANSI and the KAERI agree well with the experimental values of the ANSI N13.32 draft(1995) for each energy within 5.7%, maximum difference ratio, except for 13.6%, difference ratio in the case for the energy of less than 40keV. It is due to uncertainties of experiment occurred in the low X-ray energy range and geometry considered in the MCNP code.

  • PDF