• Title/Summary/Keyword: 확산농도

Search Result 1,155, Processing Time 0.035 seconds

Algorithms of the VLSI Layout Migration Software (반도체 자동 이식 알고리즘에 관한 연구)

  • Lee, Yun-Sik;Kim, Yong-Bae;Sin, Man-Cheol;Kim, Jun-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.712-720
    • /
    • 2001
  • Algorithms from the research of the layout migration were proposed in the paper. These are automatic recognition algorithm for the VLSI devices from it, graph based construction algorithm to maintain the constraints, dependencies, and design rule between the devices, and high speed compaction algorithm to reduce size of the VLSI area and reuse the design with compacted size for the new technology. Also, this paper describes that why proposed algorithms are essential for the era of the SoC (System on a Chip), design reuse, and IP DB, which are the big concerns in these days. In addition to introduce our algorithms, the benchmark showed that our performance is superior by 27 times faster than that of the commercial one, and has better efficiency by 3 times in disk usage.

  • PDF

Effects of Vth adjustment ion implantation on Switching Characteristics of MCT(MOS Controlled Thyristor) (문턱전압 조절 이온주입에 따른 MCT (MOS Controlled Thyristor)의 스위칭 특성 연구)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jong-Il;Kwak, Changsub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.69-76
    • /
    • 2016
  • Current driving capability of MCT (MOS Controlled Thyristor) is determined by turn-off capability of conducting current, that is off-FET performance of MCT. On the other hand, having a good turn-on characteristics, including high peak anode current ($I_{peak}$) and rate of change of current (di/dt), is essential for pulsed power system which is one of major application field of MCTs. To satisfy above two requirements, careful control of on/off-FET performance is required. However, triple diffusion and several oxidation processes change surface doping profile and make it hard to control threshold voltage ($V_{th}$) of on/off-FET. In this paper, we have demonstrated the effect of $V_{th}$ adjustment ion implantation on the performance of MCT. The fabricated MCTs (active area = $0.465mm^2$) show forward voltage drop ($V_F$) of 1.25 V at $100A/cm^2$ and Ipeak of 290 A and di/dt of $5.8kA/{\mu}s$ at $V_A=800V$. While these characteristics are unaltered by $V_{th}$ adjustment ion implantation, the turn-off gate voltage is reduced from -3.5 V to -1.6 V for conducting current of $100A/cm^2$ when the $V_{th}$ adjustment ion implantation is carried out. This demonstrates that the current driving capability is enhanced without degradation of forward conduction and turn-on switching characteristics.

A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web (HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발)

  • Lee, Ugwiyeon;Ji, Hyunmin;Oh, Jeongseok;Cho, Wansu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.39-60
    • /
    • 2019
  • Korea Gas Safety Corporation is developing consequence analysis system for combustible materials release events to enhance risk assessment technology and its efficiency. Unlike general consequence analysis programs, the final consequence area was implemented through ETA analysis based on API-581 standard, and a convenient user interface was constructed based on HTML5-based responsive web technology. In addition, a phase equilibrium module using third-order state equations (such as Peng-Robinson, SRK, and RK) and fugecity was implemented to analyze the mixture quality. Also. using the consequence analysis algorithm introduced in CCPS books and TNO Yellow Book, we developed material leak analysis module, fireball, pool fire, jet fire, flash fire, and vapor cloud explosion consequence assessment module. In addition, the conditions for calculating the safety distance were prepared with using the control values in the EIGA standard, PAC, and Bevi Reference Book.

Removal of pharmaceuticals in biologically treated sewage with $O_3$ and advanced oxidation processes (오존 및 고도산화처리에 의한 하수 2차 처리수중의 의약품류 제거)

  • Kim, Il-Ho;Tanaka, Hiroaki;Song, Ho-Myeon;Joo, Jin-Chul;Ahn, Chang-Hyuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.137-137
    • /
    • 2011
  • 급격한 세계인구의 증가에 의해 물 부족지역이 세계 각지로 확산되고 있다. 이에 따라, 건전한 수자원으로써 하수처리수의 재이용이 주목을 받고 있다. 하수처리수의 재이용시에는 특히, 재이용수의 미생물학적 안전성과 더불어 화학물질 등으로부터 기인할 수 있는 인체 및 생태계에의 리스크를 고려해야 한다. 미국 EPA는 병원성 미생물 뿐만 아니라 화학물질에 대한 안전성을 확보 차원에자외선/과산화수소 등의 고도산화처리법을 검토하였다. 1일 $10m^3$ 처리규모의 연속실험장치를 이용, 검토된 공정별 실제 하수 2차 처리수중에 존재하는 의약품류의 제거효과, 에너지 소비량 및 생태리스크 저감효과 등을 비교, 평가하였다. 에너지 소비량에 있어서는 공정별로 다소 차이가 있었으나, 본 실험동안 검출된 38종의 의약품류 제거에는 각 공정 모두 매우 효과적이었다. 에너지 소비측면에서는 오존 단독공정이 가장 적은 에너지 소비량에서 타 공정과 동일한 수준의 의약품류 서 막처리나 자외선 처리 등의 고도처리시설에 대한 정보를 재이용수 가이드라인에 제시하고 있는 반면, 우리나라에서는 재이용수중에 일정농도 이상의 염소가 잔류하도록 함으로써, 재이용수의 미생물학적 안전성 확보만을 고려하고 있다. 최근, 수환경분야에서는 의약품류라는 화학물질이 유럽, 미국 및 일본 등지를 중심으로 주목을 받아오고 있으며, 이들은 ng/L-${\mu}g$/L 수준으로 수환경중에서 검출되고 있다. 이들의 주요 발생원으로 하수처리시설이 지목되고 있으며, 따라서 하수처리수의 재이용시 잔류 의약품류에 의한 리스크 발생 가능성이 우려되고 있다. 이를 배경으로, 하수처리시설에서 의약품류를 효과적으로 제거할 수 있는 공정으로 오존 및 오존/자외선, 제거효과가 얻어졌다. 한편, 오존처리시 발암성 물질인 브로메이트($BrO_3^-$) 등과 같은 부생성물 생성 가능성을 고려하면, 오존 단독공정보다 상대적으로 많은 에너지를 소비하는 오존/자외선, 자외선/과산화수소 등의 고도산화처리법이 높은 적용성을 갖는 것으로 나타났다. 향후, 수자원 부족문제로 재이용수의 용도가 훨씬 다양해 질 것으로 예상된다. 그에 따라, 재이용수의 안전성 확보를 위해 보다 폭넓은 검토가 예상되지만, 현 단계에서는 오존을 포함, 다소 많은 에너지 소비가 예상되는 자외선을 이용한 고도산화처리법이 다양한 미량 화학물질의 제거에 유효한 공정으로 판단된다.

  • PDF

Evaluation of the Removal Properties of Cu(II) by Fe-Impregnated Activated Carbon Prepared at Different pH (pH를 달리하여 제조한 3가철 첨착 활성탄에 의한 구리 제거특성 평가)

  • Yang, Jae-Kyu;Lee, Nam-Hee;Lee, Seung-Mok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.345-351
    • /
    • 2008
  • Fe-impregnated activated carbon(Fe-AC) was prepared by Fe(III) loading on activated carbon(AC) in various preparation pH. In order to evaluate the stability of Fe-AC, dissolution of iron from Fe-AC in acidic conditions was measured. In addition, batch experiments were conducted to monitor the removal efficiency of copper by Fe-AC. Results of stability test for Fe-AC showed that the amount of extracted iron increased with contact time but decreased with increasing solution pH. The dissolved amount of iron gradually increased at solution pH 2 and finally 13% of the total iron loaded on activated carbon was extracted after 12 hr. However dissolution of iron was negligible over solution pH 3. Removal of Cu(II) by Fe-AC was greatly affected by solution pH and was decreased as solution pH increased as well as initial Cu(II) concentration decreased. Surface complexation modeling was performed by considering inner-sphere complexation reaction and using the diffuse layer model with MINTEQA2 program.

An Analysis of Flushing Effects for Instantaneous Contaminants Input into River (하천에 순간적으로 유입된 오염물질의 플러싱 효과 분석)

  • Jung, Jae-Wook;Kim, Soo-Youl;Kim, Jin-Young;Yoon, Sei-Eui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.43-50
    • /
    • 2004
  • This study had been performed to analyze flushing effects for instantaneous contaminants input with changing dam discharge in River. RMA-2 and RMA-4 models were applied to the downstream part of the Han River(from Jamsil submerged weir to Singok submerged one) The longitudinal dispersion coefficient of $50m^2/s$ was used. The four cases of dam discharges were selected as $500m^3/s,\;1000m^3/s,\;1500m^3/s$ and $2000m^3/s$, respectively, for 1 hour. The drought flow was fixed $200m^3/s$ in the Han River. The arrival time and the concentration of contaminant, the area of dispersion were estimated with RMA-4 model in the downstream part of the Han River. The arrival time which the concentration of contaminants become under 1ppm was analyzed with the stagnant and the instantaneous inflow contaminant at the section of Sungsan Bridge. The more increasing a dam discharge, the more short a dilution time of contaminant. The relation between the dam discharge and dilution time shows linearity. The instantaneous contaminant input was sensitively affected by the dam discharge than the stagnant contaminant one in the river. If it is tried to flush with a temporally increased dam discharge, it should be understood the range of overflowed contaminant dispersion from main channel to tributary channel.

Construction of Environmental Friendly Special-Purpose Ship for the Removal of Blue-green Algae (친환경적 녹조 제거용 특수선박 건조)

  • Shin, Jae-Ki;Yi, Hye-Suk;Jeong, Sun-A;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.404-406
    • /
    • 2009
  • This study note wished to introduce special-purpose ship for algae removal that is developed by core technology of our country. The ship is consisted of main frame and adjuvant that can attach and detach as cross (+) shape of a character. The characteristics of ship are super light weight and low draft. That is consisted of four devices as suction, collection, filtration and recovering units. Among these, filtration used screen filter (mesh size 30 ${\mu}m$). Also, can separate and remove water and algae by compression air participle notion. Percentage of moisture content of concentrated algal particle was 85%. Water parted with algae finally is exhausted to water area. Removal efficiency that compare by chlorophyll-$\alpha$ concentration was about 57% (inflow: 83.2 ${\mu}g\;L^{-1}$, outflow: 35.8 $[\mu}g\;L^{-1}$) without physical and chemical pretreatment. Forward, need to achieve effect test in various conditions (algal biomass, flow etc.) for efficiency and technological elevation of exclusion device. We wished to contribute in presuppression system construction of massive algal development that manage blue-green algae occurrence area effectively, and prevents spread as lower part of reservoir.

Analysis of water quality improvement efficiency using constructed wetland in a coastal reservoir (연안 담수호 수질오염 방지를 위한 인공습지의 수질정화효율 분석)

  • Hong, Jungsun;Maniquiz-Redillas, Marla C.;Ham, Jong-Hwa;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.292-300
    • /
    • 2016
  • Diverse and comprehensive countermeasures were established to prevent water pollution in coastal areas such as constructed wetlands(CW).This study was conducted to assess the water quality improvement through CW constructed along the shoreline of Hwaseong coastal reservoir. The CW is located in Hwaseong-si, Gyeonggi-do and consisted of a forebay and a wetland. The CW was monitored twice during rainy days and 10 times during dry days. The monitoring results indicated that in and out flowrates were highly correlated with COD and TN loads. COD, TN and TP concentrations in the forebay was lower during dry days than rainy days. However, concentration and mass removal efficiencies of COD, TN and TP were greater during rainy days. In addition, the volume flowing into the CW was less compared to the outflow during rainy days indicating that the CW efficiently reduced the runoff volume. The overall pollutant removal efficiency of the CW were at least 50% for TSS, 20 to 35% for TP, and 26 to 94% for TN. The data gathered may be used to improve the pollutant removal efficiency of the system in the future.

Numerical Simulation on Seawater Intrusion in Coastal Aquifer using N-S Solver Based on Porous Body Model (PBM (Porous Body Model) 기반의 N-S Solver를 이용한 해안대수층의 해수침투모의)

  • Lee, Woo-Dong;Jeong, Yeong-Han;Hur, Dong-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.12
    • /
    • pp.1023-1035
    • /
    • 2015
  • This study applies 3-D N-S solver based on PBM (Porous Body Model), LED-WASS-3D ver 2.0 to directly analyze non-linear interaction of seawater-freshwater-coastal aquifer in order to simulate the seawater infiltration into coastal aquifer. This numerical simulation is the first trial in Korea, as well as unusual and new numerical analysis abroad. Firstly, to validate the applied numerical model, the validity and effectiveness was verified for the numerical model by comparing and considering it with the result of laboratory experiment for seawater-freshwater interface in coastal aquifer. And then it simulated the seawater infiltration into coastal aquifer considering the changed levels of seawater and groundwater in order to analyze the distribution characteristics of flow field and seawater-freshwater interface of coastal aquifer as the level difference between seawater and groundwater and rate of seawater level (${\Delta}h/h$) increased. In addition, the characteristics of seawater infiltration were analyzed from the vertical salinity in the coastal aquifer by ${\Delta}h/h$, which cannot be obtained from existing non-diffusion numerical models. Finally, it analyzed the effect of ${\Delta}h/h$ on the seawater infiltration distance in coastal aquifer, which was indexed.

A Impact Analysis of Air Quality by Air Pollution Control Facilities Improvement on Point Source Pollution (점오염원의 대기오염방지시설 개선에 의한 대기질 영향 분석)

  • Jeon, Byeong-Geun;Lee, Sang-Houck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2876-2882
    • /
    • 2015
  • The object of this study is to identify changes in air pollution in the maximum ground level concentration and the surrounding area when air pollution control facilities are improved in the thermal power plants. The effects of improved facilities are analyzed by comparing air quality after applying improved air pollution control facilities. For prediction of air quality, the change of wind field can be represented with movement of Puff and CALPUFF Model, air pollution diffusion models which can implement abnormal conditions. Major air pollutants of thermal power plants such as $SO_2$, $NO_2$, and $PM_{10}$ are selected as prediction items. That results show that improvement of air pollution control facilities is significantly effective in reduction of air pollution of $SO_2$ and $NO_2$ in the maximum ground level concentration and areas around of thermal power plants. In the case of $PM_{10}$, it is found that the effect of reduction in pollution is high in the maximum ground level concentration, but the effect of reduction in air pollution is somewhat low in the area around of the thermal power plant.