• Title/Summary/Keyword: 화재 예방

Search Result 833, Processing Time 0.025 seconds

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가)

  • Song, Jung Soo;Yu, Jong Min;Han, Seung Youn;Choi, Jeong Woo;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • The proportion of natural gas-fueled power generation is expanding due to the change of domestic energy policy pursuing reduction of dust and increasing clean energy consumption. Natural gas fuels used for the combined-cycle power plants and the district-heating power plants are operated at high temperature and high pressure in the fuel supply system. Accidents due to leakage of the gas such as fire and explosion should be prevented by applying risk management techniques. In this study, risk assessment was performed on the natural gas fuel supply system of a combined power plant based on the API RP 581 RBI code. For the application of the API RBI code, lines and segments of the evaluation target system were identified. Operational data and input information were analyzed for the calculations of probability of failure and consequence of failure. The results of the risk assessment were analyzed over time from the initial installation time. In the code-based evaluation, the gas fuel supply system was mainly affected by thinning, external damage, and mechanical fatigue damage mechanisms. As the operating time passes, the risk is expected to increase due to the external damage caused by the CUI(Corrosion Under Insulation).

Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant (방염 처리 고목재의 미생물 분해의 미시형태적 특징)

  • Wi, Seung Gon;Kim, Ik-Joo;Park, Young Man;Kim, Yoon Soo
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.27-34
    • /
    • 2001
  • Following the recommendations made by the cultural authorities the wooden cultural properties (WCP) had been treated with fire-retardants for fire protection. However, visual inspections of some of the WCPs treated with fire-retardants showed microbial decay. The work was extended to examine the micromorphological characteristics of the WCPs in a Buddhist temple which had been treated with fire-retardant. Microscopic examination showed the presence of typical soft rot cavities along the length of microfibrils in the secondary wall. Bacterial attack was also observed by scanning and transmission electron microscopy. It is interesting that the decay patterns observed in the Buddhist temple were very similar to those observed in the waterlogged woods. Presumably chemicals in the fire-retardants used rendered the wood susceptible to attack by soft-rot and bacterial decay by causing an increase in the moisture content of wood. Further studies are needed to investigate the effect of fire-retardants used currently on the hygroscopicity and the strength of wood materials in the WCPs. Microbial attacks caused degradation of the secondary cell walls and in some cases also of the middle lamella. In addition, the cell walls in the outer parts of wood were also degraded due to weathering, and cell separation occurred from total disintegration of the middle lamella.

  • PDF

Climate Change Adaptation and the Role of Special Weather Warning (기후변화 적응과 기상특보의 역할)

  • Park, Jong-Kil;Jung, Woo-Sik;Oh, Jin-A;Kim, Eun-Byul;Choi, Soo-Jin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.173-173
    • /
    • 2011
  • 최근 기후변화로 인한 기상재해 중 건조와 관련하여 인플루엔자, 호흡기질환 등과 같은 질병과 산불발생빈도의 증가로 인해 건강 및 재산상의 피해가 증가하고 있다. 특히, 한반도의 주택지역은 산림지역과 근접하여 산불 발생시 그 피해와 복구비용이 막대한 것으로 나타났다. 뿐만 아니라 향후 지구온난화가 가속화 될 경우 건조와 관련한 환자와 산불로 인한 피해가 증가할 것으로 예상되므로, 이에 대한 사전방재계획 및 복구계획 등이 필요하다. 이와 같은 건조현상 등의 자연재해에 대한 방재계획이 효과적으로 운영되기 위해서는 방재 정보를 인지하고 실천하는 개인의 적극적인 활용이 필요하다. 특히, 개인의 생활에 영향을 미치는 피해는 정부적인 대책보다 개인이 스스로 인지하여 대비함으로써 감소시킬 수 있기 때문에 재해에 대한 개인의 인지정도는 대책마련에 있어 중요한 요인이 된다. 이에 따라, 본 연구에서는 건조로 인한 질병 및 산불 발생 등 기상재해 증가에 대한 사전방재계획의 효과적인 운영을 위하여 설문조사분석을 통한 일반인의 건조특보 인지도 및 활용도 분석을 실시하였다. 또한, 기후가 변화함에 따라 더운 낮과 밤의 증가로 건조현상뿐만 아니라 폭염의 발생빈도도 증가할 것으로 예상되고 있다. 이와 관련하여 기후변화 적응측면에서 국민들의 건조특보 및 폭염특보와 관련한 정보 습득이 잘 이루어지고 있는지를 파악하고자 한다. 이를 위해, 선행연구에서 대학생의 주된 폭염특보 관련 정보습득경로가 TV와 인터넷인 점을 참고하여, 기상청에서 제공하는 건조특보와 폭염특보 발표일수와 TV, 인터넷의 대중매체를 통한 보도회수를 비교 분석하였다. 본 연구를 통해 대학생집단과, 10대, 20대의 저연령층의 인지도가 상대적으로 낮은 것으로 파악되었으며, 이는 대중 매체를 통한 건조특보와 관련한 정보전달의 부족으로 나타났다. 폭염특보와 관련한 언론보도는 기상전달뿐만 아니라, 폭염의 위험성, 폭염으로 인한 피해상황, 폭염특보제 홍보, 폭염과 관련한 대비책 등 다양한 내용으로 기재되었다. 반면에, 건조특보의 경우에는 대부분이 단순 기상전달로 폭염특보에 비해 보도의 다양성이 결여되어 있었다. 차후 대중매체를 통한 이용자들의 접근성을 증대시키기 위해서 신속하고 정확한 정보전달이 필요하다. 산불 및 화재예방과 관련하여 기상청의 정확한 기상정보 제공과 사전방재계획 수립에 대한 필요성을 직업별, 연령별로 구성된 각 집단의 50%이상이 느끼는 것으로 나타났다. 이에 따라, 기상정보 전달의 핵심인 기상청을 중심으로 온라인/오프라인 상의 기초교육부터 체계적인 사전방재계획 및 안전교육 프로그램 마련이 필요하다.

  • PDF

Development of Laboratory Safety Management System for Chemistry and Chemical Engineering Laboratory (화학 및 화학공학 실험실의 안전관리 시스템 개발)

  • Yoo, Jin Hwan;Lee, Heon Seok;Choi, Joung Woo;Seo, Jae Min;Park, Chulhwan;Ko, Jae Wook
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.376-382
    • /
    • 2008
  • There are many accidents such as fire and explosion in laboratories that have caused a great loss to lives and property in spite of the effort to the enhancement of laboratory safety level for years. Development of laboratory safety management system is a necessary to improve safety level because the accidents of similar types have periodically occurred in laboratories. The laboratory safety management system may reduce many accidents and a serious loss in laboratory. In this study, we summarized major items for a risk management and safety improvement based on the analysis results of various accidents in the laboratories. And then the laboratory safety management system was developed containing a laboratory safety management manual, a laboratory management system, a education management system, a MSDS (material safety data sheet) management system and a laboratory safety audit system. It may have a potential application for the laboratory safety management in the chemical laboratories.

The Study on the dweller's Expressions of Apartment Facility Management in accordance with Built Year (준공연수에 따른 공동주택 관리에 대한 주민인식 비교분석)

  • Choi, Yeol;Ha, Kyu Yang;Kim, Jong-Gyeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.149-155
    • /
    • 2011
  • The aim of this study is to grasp how the dwellers of apartment cognize the real condition of the management such as general control of janitor office or management of maintenance, environment, account and imposing price of management. The analysed results of recognition are as following. First, as the dwellers judged that the janitors are incapable to control dispute among the households, it needs to develop the ability to cope with the demand of control dispute by various curriculum. There should be more strict management of parking lot for the handicapped. Second, it needs to establish the plan to improve maintenance of the rest facility. Third, as dwellers thought the management expenses not to be made public clearly, it needs to use various way, not only by neighborhood meeting but also information system such as establishing web page or E-mail notice for better announcement of the settled matters such as management expenses. Forth, the audit result of management expenses and the measures conducted after audit should be reported widely, contract of construction work services needs to be publicized by neighborhood meeting or other information system.

Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station (발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2017
  • The only method used in the power stations in order to deliver generated electric power is 6 kV XLPE (or CV) single core cables. Among many kinds of accidents happening in the power stations, the outbreak of fire due to the deterioration of live cables causes enormous socioeconomic losses. From the installation of the cables, the management and diagnose should be thoroughly made. Even though it differs depending on the installations and usage conditions, the cross-sectional area of cables is in shortage. The excessive allowable temperature caused from the current causes the deterioration of cables. In order to prevent an unexpected breakdown of live cables, we have invented a device to monitor and diagnose the status of cables. We have installed our device in the Korea Western Power Co., Ltd.. In this paper, we present our research results in situ that we have obtained by measuring the temperature of sheath, changing with the surrounding circumstances, especially ambient temperatures. We also show our study results of characteristics for temperature of sheath surface and load current at the ambient temperatures of $40^{\circ}C-10^{\circ}C$.

The Continuity of Operation (COOP) Application to a Local Government for Disaster Risk Reduction

  • Jang, Young-Jin;Wang, Won-joon;Jung, Jae-Wook;Seo, Yong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.157-166
    • /
    • 2019
  • Globally, various disasters such as typhoons, floods, earthquakes, fires, explosions have caused work to be halted. If there is a large-scale disaster at public institutions in charge of major national affairs and their works are interrupted, not only will there be property damage, but there will also lead to a decline in national credibility and direct and indirect impacts on the people. Therefore, it is necessary to ensure continuity of operation by minimizing the interruption period of critical operations due to disasters. Overseas advanced countries such as the United States and Japan developed guidelines for Continuity of Operation (COOP) to prevent unexpected work disruptions caused by disasters. Recognizing the necessity of COOP in South Korea, a relevant law has been newly established in 「the Framework Act on the Management of Disasters and Safety」 to enable public institutions to establish the COOP in response to this situation. In this study, the definition, the necessity and overseas cases of COOP were investigated and described. Using the templates developed by these results, operational impact analysis, risk assessment, operational continuity strategies and operational continuity procedures were applied to "A" City Hall in Gyeonggi-do province and those results were described. The objective of this study is to substantially contribute to the introduction of COOP to local governments through their pilot application and implications of COOP.

A Study on Characteristics of Auto Ignition and Activation Energy of Ethylene Glycol and Diethylene Glycol (Ethylene Glycol과 Diethylene Glycol의 자연발화 특성과 활성화에너지에 관한 연구)

  • Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.16-22
    • /
    • 2016
  • Auto ignition characteristic is an important factor for handling combustible substance and fire prevention. This research studied about auto ignition characteristic and activation energy of Ethylene Glycol (EG) and Diethylene Glycol (DEG) by using ASTM D2155 type ignition temperature measuring apparatus. As the auto ignition temperatures, it was possible to get $434^{\circ}C$ for EG within sample amount range of $75{\sim}160{\mu}l$ and $387^{\circ}C$ for DEG within sample amount range of $130{\sim}150{\mu}l$. Also, it was possible to get $579^{\circ}C$ and $569^{\circ}C$ as instantaneous ignition temperatures with sample amount of $140{\mu}l$ for EG and DEG respectively. By using least square method from Semenov equation on measured ignition temperature and ignition delay time from this study, it was possible to calculate activation energy of EG as 25.41 Kcal/mol and DEG as 14.07 Kcal/mol. Therefore, it was possible to claim that DEG has more risk of auto ignition since the auto ignition temperature, instantaneous ignition temperature and activation energy of DEG is lower than EG.

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

An Improvement in Level of Facility Security Operation (시설보안 운영수준 향상방안)

  • Chung, Tae-Hwang;Chang, Hang-Bae
    • Korean Security Journal
    • /
    • no.32
    • /
    • pp.205-225
    • /
    • 2012
  • This study is to present an improvement of facility security through the evaluation of facility security operation level. To fulfill the purpose of the study, a survey of some facilities was conducted and the result was analyzed as follows; First, although security personnels were deployed in the facilities, the level of security personnel operation was relatively low. Second, job education training level was relatively proper, that is relevant to the result that show the level of service mind and the working mind of security personnel were proper, also relevant to the relatively good work shift system. Third, although situation room was operated well, the level of restricted area set-up and access control of visitor were low, and the level of article inspection and vehicle access control were very low. Forth, the level of security manual application that include detailed security method and procedure was proper. But accident prevention and response manual application was lower than security manual application, that show preparation for fire and negligent-accident is passive. For the improvement of facility security, the high level part and low level part in the survey result could be merged. For example, we could specify factors that show low level in the survey such as security personnel operation, access control of visitor and vehicle, article inspection, accident prevention and response in the security manual and promote education circumstance that show high level.

  • PDF