• Title/Summary/Keyword: 하수처리시스템

Search Result 271, Processing Time 0.03 seconds

Modeling Fate and Transport of Organic and Nitrogen Species in Soil Aquifer Treatment-(I) Model Development and Verification (토양/대수층 처리(soil aquifer treatment)에서 유기물과 질소화합물 제거와 이송 모델링-(I) 모델 개발 및 검증)

  • Kim Jung-Woo;Kim Jeong-Kon;Cha Woo-Suk;Choi Hee-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.9-15
    • /
    • 2005
  • Soil aquifer treatment is a water reuse technology that secondary or tertiary treated wastewater is infiltrated into the aquifer in which physical and biochemical reactions occur. Major consideration in SAT is the removal and transport of DOC and nitrogen species. In this study, reaction mechanism in SAT was examined considering nitrification, denitrification and organic oxidation. In addition, SAT modeling system was developed as the reaction mechanism was applied to groundwater flow and transport model. In verification of the reaction module by 1-dimensional unsaturated soil column test, the experimental data of all of the species, ammonium, nitrate, DOC and DO, were well matched with the simulation results. In sensitivity analysis, ammonium partition coefficient, dissolved oxygen inhibition constant and biomass decay rate affect ammonium, DOC and DO concentration of effluent, respectively.

A Study on the Sewerage Facility Management Technique based on GIS (GIS를 이용한 하수도 시설물 관리 방법에 관한 연구)

  • 최재화;박희주;이홍술
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.11 no.2
    • /
    • pp.43-51
    • /
    • 1993
  • It is very important entity that a map of urban facility is in civic life and development of city. But now, there are many needs of computerization which was used for management of urban facility map because inefficiency was produced due to management of urban facility map by hand. This paper, it was showed that a processing of establishing database in computer by applying GIS. The used sample area in studying in Ansan city in Kyunggi province and a sewer pipe which was in there adapted to establish database in computer. A map of administration district, which is 1:38,000, a map of complex urban planning of city, which is 1:3,000, and the facility map were used for the input of spatial data and the address, the year when sewer pipe was burried, and the quality of pipe, the pipe diameter, and the length of pipe were used as attribute data. Relational structure was used for establishment of database then, searching, analyzing, and processing were possible. Additionary, the result of this studying can be used for replacement of a old sewer pipe, a material quantity which is related with repairement of sewer pipe, and calculation of time, cost by application program framed by Fortran.

  • PDF

Sludge Pre-Treatment by Hydrodynamic Cavitation-I: Optimization of Pre-Treatment System (수리동력학적 캐비테이션을 이용한 하수 슬러지의 전처리-I: 전처리 시스템의 최적화)

  • Maeng, Jang-Woo;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1119-1125
    • /
    • 2010
  • Most of the sludge pre-treatment methods to improve the anaerobic digestibility of sludge are not practied in the fields with low economical efficiency. The venturi cavitation system (VCS) adopting hydrodynamic cavitation is simple and requires low energy. This research was conducted to investigate the optimum design and operating conditions of the VCS. The experimental results indicated that the optimum number of venturi in series was three, and the suction mode operation of the pump yielded 1.6 times higher pre-treatment efficiency per unit energy consumption than the discharge mode. The combination of venturies with different throat sizes did not affect the pre-treatment efficiency. Also, the parallel installation of the three in series venture unit yielded 30% higher pre-treatment efficiency per unit energy consumption than the single unit. Under parallel conditions, the solubilization efficiency was 5.6 mg ${\Delta}SCOD/g$ TS/kWh, which is higher than the previously reported value.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Effect of Wet Milling on Scum Generation and Solubilization in Batch Ozone Reaction Using Digested Sludge (소화슬러지를 이용한 회분식 오존반응 시 습식분쇄가 스컴 생성과 가용화에 미치는 영향)

  • Hong, Seong-Min;Lee, Dong-Hoon;Kim, Choong-Gon;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.13-18
    • /
    • 2019
  • Sewage sludge treatment is increasing every year due to improvement of living and urbanization. However, interest in anaerobic digestion which is one of the recycling technology. There is anaerobic digestion of increasing due to limitations of ocean dumping and final disposal. But, the limit of anaerobic digestion efficiency due to the advanced treatment of sewage has been limited, and studies for solubilization technology have been actively conducted. Therefore, in this study, we aimed to investigate the variation of generation of scum and the solubilization efficiency in the application of pre-treatment of ozone reaction and the change of properties of digested sludge with wet milling. There are results of VS/TS increased by 4.4% and $SCOD_{cr}/TCOD_{cr}$ increased by 9.4% by wet milling alone. In addition, the increase of the specific surface area due to which the reduction of the particle size of the solid content of the sludge in the ozone reaction caused by wet milling decreased the generation rate of scum at 14.3% and increased VS/TS at 2.1%, compared with the ozone reaction alone. From these results, it is expected that the application of wet milling can be increased the contact efficiency with solids in the sludge during ozone reaction with suppress scum and increase the efficiency of the subsequent process in anaerobic digestion.

VDT작업대 설계의 인간공학적 연구

  • 권영국;이성렬;민재형
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.581-591
    • /
    • 1992
  • 최근 급속한 사무자동화와 함께 컴퓨터의 사용이 보편화되어 가지고 있다. 이에 따라 컴퓨터등 VDT에 매달려 일하는 사무직 근로자들이 시력장해, 두통, 어깨결림, 요통, 스트레스성 장애등 새로운 질병에 시달리고 있다. 이것은 "VDT증후군"(Visual Display Terminal Syndrome) 또는 "VDT병"이란 신종 직업병이다. 컴퓨터 수상기 화면을 계속해서 들여다보면 화면에서 나오는 자외선과 강한 빛으로 눈에 무리가 와 충혈되고 침침해지며 두통 증세가 나타난다. 이런 초기증상이 6개월이상 계속되면 시력이 떨어지고 만성피로를 느끼는가 하면, 때때로 독감과 비슷한 증상이 나타나며, 심하면 탈모현상까지 경험하게 된다. 요즘 시행되고 있는 초등 고교 컴퓨터교육의 의무화와 2천년대의 1가구 1단말기 설치를 목표로한 컴퓨터 영상단말기의 급속한 보급으로, 앞으로는 사무실뿐만 아니라 일반 가정에까지 컴퓨터 이용이 일상화될 전망이고 보면 VDT작업에 따른 건강장해 문제는 더이상 가볍게 볼 수 없는 문제이다. 이에 대해 선진국에서는 작업시간 규제, 회사가 종업원의 정기적인 시력검진 및 시력교정에 필요한 비용을 보조하도록 하는가하면 실작업환경 개선등 다각적인 대책을 마련하고 있다. 미국, 유럽, 일본등 선진국에서는 VDT작업 여성들의 유산 및 기형아 출산등 임신이상에 관한 실태보고서까지 나오고 있어 여성들에게 커다란 충격을 던져주고 있다. 그러나 우리나라에서는 VDT병 증상을 호소하는 근로자들의 직업병예방 및 대책에 큰 어려움을 겪고있다. 그러므로, VDT작업으로 인한 건강상의 문제, 작업환경 및 작업자세등을 조사하여 문제점과 예방대책을 살펴보고, 작업장을 인간공학적으로 설계하고 평가하여 사용자의 건강을 보호하고 생산성의 향상에 도움이 되고자 한다.생산성의 향상에 도움이 되고자 한다.Action Code를 계산처리부로 넘겨준다. 입력처리부에서는 Mouse와 Keyboard 어느것으로나 입력이 가능하도록 해준다. 출력처리부에서는 Action Code에 따라 계산처리부에서 계산된 결과를 화면에 보여주기 위한 각종 2D/3D Graphic Routine들이 포함되어있어 계산처리부에서 불러쓰도록 되어있다.에서는 전문가시스템 기법을 도입해서 사출금형 공정계획전문가의 지식과 경험을 획득하여 지식베이스를 구축하고, 전문가시스템 셀(shell)중 CLIPS를 이용하여 자동공정계획시스템인 Mold CAPP을 개발하였다.PP을 개발하였다.며 이와 상이한 결과도 보여주고 있다. 이상으로 볼 때 1) 가정하수의 질을 높이기 위하여 분뇨정화조 의 효율증대 2) 산업폐수의 공정별 폐수량의 조절 및 폐수성 상에 따른 총량규제에 대비한 효율증대 3) 하천의 오염부하와 자정능력 최대한 부여 4) 폐수처리를 위한 미생물제개발 및 오염지표 종 연구와 오염내성 생물의 연구등이 종합적 으로 수행되어야 한다. 5) 이상의 모든 조사와 연구결과를 객관적으로 표기할 수 있도록 하천의 이정표가 정해져야 하겠다.7%)에 비해 유의하게 낮았고 정상군과는 유의한 차이를 보이지 않았다.상고나성이 있었다. 혈중 호모시스테인 농도는 질병의 위험요인으로서 뿐 아니라 대사적으로 밀접하게 연관된 비타민 영양상태의 biomarker로서도 그 영향력이 크다고 할 수 있다. 따라서 성별에 다른 다양한 연령집단에서 건강한 일반인과 심혈관계 질환자 등을 대상으로 호모시스테인과 비타민 영양상태에 대한 연구가 체계적으로 이루어 져야 할 것이다.태를 보다 효율적으로 증진시킬 수 있는 대안이 마련되어져야 한다고 사료된다.$\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도

  • PDF

Evaluation of Water Quality Management of Estuarine Reservoir Based on Resilience Analysis Framework (회복탄력성 프레임워크 기반 담수호 수질 개선 방안 평가)

  • Hwang, Soonho;Jun, Sang Min;Kim, Seok Hyeon;Lee, Hyunji;Kwak, Jihye;Kang, Moon Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.348-348
    • /
    • 2020
  • 우리나라 하구에 조성된 담수호의 수자원은 다양한 용수 목적에 맞게 활용하고 있으며, 수질 기준에 부합하는 용수를 공급하고 담수호 및 간척지의 친환경적 가치를 높이기 위해서는 담수호의 상류 유역 및 유입 오염물질, 그리고 담수호 수체 특성에 대한 종합적인 이해를 기반으로 수질 오염 관리 대책을 수립하는 것이 중요하다. 일반적으로 담수호 개선을 위한 방안의 선정 방식은 연평균 수질 농도를 기준으로 목표하고자 하는 수질 기준의 만족 여부에 대한 평가와 경제적 평가를 함께 고려하여 최적의사결정 기반으로 주로 이루어져 왔다. 그러나 기존의 평가 방법에서는 목표 수질의 만족 여부가 중요하다는 점에서 담수호 수자원의 시기별 활용성에 대한 고려를 간과하기 쉽다. 또한 담수호 수자원 시스템의 수질 악화에 대한 회복탄력성을 높이는 일은 단순히 유역관리대책의 적용에 따른 수질 개선 문제와는 별도로 담수호 수자원 시스템의 지속 가능성과 연관된다는 점에서 기존의 평가 방식을 보완하기 위한 수단이 필요하다고 할 수 있다. 따라서 본 연구에서는 담수호 수자원 관리 방안을 평가하는 데 있어서 회복탄력성의 개념을 활용하였으며, 각 방안에 대한 시간적 변화에 따른 담수호의 회복탄력성 특징을 고려하기 위하여 동적 회복탄력성 개념 및 평가 방법을 도입하였다. 본 연구에서는 우선 기존의 수질 평가 방법에 따라 간월호를 대상으로 수질 개선 방안별 수질 변화를 SWAT-EFDC 연계모형을 통해 모의하고, 연평균 수질 농도와 총인 삭감량에 대해 분석하였다. 분석 결과, 간월호의 지형학적 특성에 따라 간월호 상류 구간의 수질 농도가 다른 구간에 비해 높게 나타났으며, 상류 구역의 경우 준설 시나리오만으로는 목표 수질을 달성하기 어려운 것으로 나타났다. 따라서, 상류 구역의 수질 목표 달성을 위해서는 준설 시나리오만으로는 한계가 있으므로 상류 유역 출구부에 위치한 하수처리시설의 총인 배출부하량을 삭감과 추가적인 유역 수질 관리 대책이 필요하다.

  • PDF

Microbial Communities and Diversities in a Full-Scale Mesophilic Anaerobic Digester Treating Sewage Sludge (하수슬러지 처리 실규모 중온 혐기성 소화조 미생물 군집 및 다양성 조사)

  • Minjae Kim;Suin Park;Juyun Lee;Hyebin Lee;Seonmin Kang;Hyokwan Bae;Joonyeob Lee
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1051-1059
    • /
    • 2022
  • This study investigated microbial communities and their diversity in a full-scale mesophilic anaerobic digester treating sewage sludge. Influent sewage sludge and anaerobic digester samples collected from a wastewater treatment plant in Busan were analyzed using high-throughput sequencing. It was found that the microbial community structure and diversity in the anaerobic digester could be affected by inoculation effect with influent sewage sludge. Nevertheless, distinct microbial communities were identified as the dominant microbial communities in the anaerobic digester. Twelve genera were identified as abundant bacterial communities, which included several groups of syntrophic bacteria communities, such as Candidatus Cloacimonas, Cloacimonadaceae W5, Smithella, which are (potential) syntrophic-propionate-oxidizing bacteria and Mesotoga and Thermovigra, which are (potential) syntrophic-acetate-oxidizing bacteria. Lentimicrobium, the most abundant genus in the anaerobic digester, may contribute to the decomposition of carbohydrates and the production of volatile fatty acids during the anaerobic digestion of sewage sludge. Of the methanogens identified, Methanollinea, Candidatus Methanofastidiosum, Methanospirillum, and Methanoculleus were the dominant hydrogenotrophic methanogens, and Methanosaeta was the dominant aceticlastic methanogens. The findings may be used as a reference for developing microbial indicators to evaluate the process stability and process efficiency of the anaerobic digestion of sewage sludge.

Physical and Chemical Analysis of Organic Wastes for the Establishment of Total Management System (유기성 폐기물 종합관리기술구축을 위한 물리·화학적 성상 분석)

  • Kim, Young-Koo;Phae, Chae-Gun;Choi, Hoon-Keun;Kim, Sung-Mi;Hwang, Eui-young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.1
    • /
    • pp.100-114
    • /
    • 2005
  • Organic waste, which is defined as wastes derived from various biological organisms that contain more than 40% of organic materials, is generated about 100 million tons per year in Korea. These organic wastes are now controlled by several governmental entities, under different rules and regulations, leading to the improper management and inefficient treatment. Therefore, integrated management system is primarily needed for the efficient recycling of organic waste. In this study, six kinds of organic wastes, which are food waste, sludges(sewage, waste water, night soil), animal excreta, animals and plants residues, and three kinds of recycling by-products(compost, feed, anaerobic digestion by-products) made of organic wastes, were analyzed for their physical and chemical characteristics. On the basis of this result, a possibility for the efficient recycling of organic waste was investigated.

  • PDF