• Title/Summary/Keyword: 피난 안전성

Search Result 253, Processing Time 1.999 seconds

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

Factors Affecting Potential Disaster Damage and Perceptible Stress Influencing Evacuation Behavior (재난피해가능성불안 및 지각된 스트레스가 대피행동에 영향을 미치는 요인)

  • JI, Youngil;Moon, YooMi
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.594-601
    • /
    • 2020
  • Purpose: The purpose of the present study was to identify factors affecting anxiety about disaster damage potential in Gyonggi-do and evacuation behavior that influences evacuation behavior. Method: Multiple regression analysis was performed to test the hypothesis and to analyze the influence of anxiety about disaster damage potential and perceived stress, and analyzed similarity in correspondence between age and anxiety about disaster damage potential. Results: The anxiety about disaster damage potential of a group vulnerable to safety and anxiety about disaster damage potential of disaster system collapse were perceived in close proximity. Disaster system collapse, evacuation life, and natural disasters were found to be factors affecting perceived stress. Stress and natural disasters were found to be influencing factors on evacuation behavior. Conclusion: The necessity of managing stress was confirmed since anxiety about natural disaster damage potential and stress affect evacuation behavior. The recent experiences of heavy rain disasters indicate that the anxiety about disaster damage potential is expected to increase. The findings also indicate the importance of preventive planning and psychological management to manage the anxiety about disaster damage potential.

Trends of Research and Practical Use on Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete (고강도콘크리트의 폭렬대책공법에 대한 국내외 현황과 성능적 구조내화설계를 위한 과제)

  • Kwon, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.935-940
    • /
    • 2008
  • When reinforced concrete is subjected to high temperature as in fire, there is deterioration in its properties of particular importance are loss in compressive strength, cracking and spalling of concrete, destruction of the bond between the cement paste and the aggregates and the gradual deterioration of the hardend cement paste. Assessment of fire-damaged concrete usually starts with visual observation of color change, cracking and spalling of the surface. In this paper, it was reported the trends of research and practical use on the Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete.

  • PDF

Study on the Ship Fire Analysis According to Explosion Hazard (폭발의 위험성에 의한 선박화재의 사고사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • This study analyzed recent cases of ship fires explosions and investigated their problems and coping plans. Through analysis on the statistical figures, it was found that our nation's situations of maritime accidents by kind during the period of 2009~2013 showed the ratios of ship accidents caused by fires explosions was the highest in 2012 with 7.58% (55 cases) followed by year 2009 with 3.39% (34 cases), year 2010 with 3.39% (25 cases), year 2011 with 6.03% (57 cases) and year 2013 with 6.74% (43 cases), which indicates a steady increase in the number of ship accidents. Majority of reasons for ship fires explosions were lack of safety awareness. Since those accidents happen on the sea, fires, once they happen, tend to get serious due to absence of on board & nearby fire extinguishing facilities, public fire service's uneasy access to them and great influences of natural factors such as wind and etc. Ship fires explosions are special cases unlike what happens to general edifices. So, their coping plans should focus on preventive measures since the damages those cases bring about can be detrimental. For this reason, it's necessary to research precise evacuation plans, develop ship structure & materials reinforcing fire resistance to secure more time for evacuation and enhance people's safety awareness by implementing thorough safety training.

A Study on the Behavior of an Existing Tunnel and the Safety Implications on its Facilities from a New Tunnel Blasting (신설 터널 발파 시 기존 터널 거동 및 시설물 안전에 관한 연구)

  • Kim, Sung Hoon;Cho, Woncheol
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 2010
  • In this study, the behavior and safety of an existing tunnel and its facilities are investigated when a new tunnel adjacent to the existing tunnel is blasted. The design of the new tunnel puts priority on stability of the tunnel itself over the safety of the facilities which are installed within the existing tunnel such as jet fans. And thus, a detailed consideration on securing the safety of the existing facilities has been insufficient. An analysis on the types of traffic accidents in the last ten years shows that most incidents were due to the driver's improper response in emergency situations and unexpected obstacles. In consideration of this analysis, the safety of the facilities in the existing tunnel was secured by minimizing the charging amount for each hangfire and changing the excavation method of evacuation communication shelters to the large center hole cut blasting method to reduce blasting vibration. For a more quantitative analysis, measurement devices were installed inside the existing tunnel, at houses adjacent to the new tunnel, near jet fans in the existing tunnel. This enabled real time measurement of displacements of the existing tunnel, adjacent houses, and jet fans without interrupting traffic flow. Therefore, the improvements of charging amount for each hangfire, the blasting method, and the measurement method are suggested in this paper to secure the safety of the facilities in the existing tunnel when a new tunnel, located on a large city and adjacent to an existing tunnel, is designed.

  • PDF

The Study on the Comparison of Building Use Classification between Building Act and Installation.Maintenance & Safety Management of Fire-Fighting System Act (건축법과 소방시설 설치유지 및 안전관리에 관한 법령간 건축물 용도분류체계 비교 연구)

  • Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-119
    • /
    • 2009
  • Building use classification is classified the building types according to the similar structure, the goal of the use, and its shape. The important reason of building use classification is that building restrictions are applied according to building use classifications. But there are a lot of confusion because the building use classification is regulated not only by the Building Act but also by the several individual Act. Particularly in the large-scaled, high-raised and complex building construction, it is very important to remain the consistency of the building use classification between the Building Act and the Fire-Fighting System Act for safety of occupants. So the purpose of this study is to suggests the improve direction of the building use classifications through the comparative analysis of the Building Act and the Fire-Fighting System Act.

A Study on the Actuality of School Safety and the Development of Safety Manual (학교안전교육의 실태분석과 안전교육매뉴얼 개발에 관한 연구)

  • Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.83-88
    • /
    • 2005
  • It is necessary to hold the school safety manual because recently, the safety-related accidents occur frequently in schools. Accidents can occur inside of schools as well as out of schools, and they can be classified with human accidents, traffic accidents, fire accidents, and explosion accidents. Safety-related accidents occurring in the school are dangerous because nobody can predict them. Illegally infringing violence, targeting unspecified and a lot of people, informs the parents and persons concerned to education of danger. School safety manual, never precedented before, describes epoch-making educational methods for students' safety. It describes safety security such as refuging ways at an emergency, the way to recognize danger for elevated safety based on prevention education, the use and practice of checklist for related facilities, and the implements and facilities for school personnels and students. So, the school safety manual is an important guidance for safety education at the level of prevention from various accidents which occur inside the school as well as out of the school. It presents a variety of prompt response after an accident. At the same time, it checks facilities and dangerous factors in schools and facilities for safety, and analyzes special factors based on them. So it will present the status of safety management of existing facilities and implements, the installment of new facilities and implements, and the way to secure safety for use.

A Study on the Trends of Research and Application of FDS in the Overseas Country (국외 FDS 연구동향 및 적용사례 분석)

  • Lee, Rang;Kim, Ding-Eun;Kim, Bong-Chan;Lee, Jae-Won;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.19-22
    • /
    • 2011
  • 최근 국내의 경우 FDS를 이용한 성능설계, 화재영향평가 및 피난안전성평가와 더불어 화재조사분야에 이르기까지 다양한 분야에서 활발하게 사용되고 있는 반면 FDS의 소스코드의 분석 및 검증등과 관련한 연구는 매우 미비하며 그결과 또한 구체적인 문제점제시보다는 FDS를 활용하여 실험결과와를 대비하는 수준에 머물러 있는 상황이다. 따라서 본연구는 FDS의 검증을 위한 외국사례를 조사분석하여 향후 국내에서 FDS의 활용시에 대한 주의점 및 향후 한국에서의 활용을 위한 개선방안을 도출한 것이다.

  • PDF

A Study on risk management measurers about High-rise APT (고층아파트 위험관리 방안)

  • Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.178-187
    • /
    • 2013
  • This paper studied the potential risk of high-rise apartment by analysis of the loss ratio of housing fire insurance, statistics related high-rise apartment fire, and the insured amount of housing fire insurance, and, found that it is so high and need the improvement of risk management measures for high-rise apartment. Accordingly, the study recommend the composit risk management measures including preventing of fire expanding for higher stories, a shelter for people of hire-rise apartment, and sprinkler protection, etc. Also as risk transfer measures, the composit risk measures for high-rise apartment includes the full insurance of housing fire insurance, third party property liability insurance, and development of endorsement for special risk such as a typhoon, liability etc.