• Title/Summary/Keyword: 콘크리트 양생

Search Result 739, Processing Time 0.023 seconds

Estimation of Compressive Strength of Concrete Incorporating Admixture (혼화재 치환 콘크리트의 압축강도 증진해석)

  • Joo Eun-Hee;Pei Chang-Chun;Han Min-Cheol;Sohn Myoung-Soo;Jeon Hyun-Gyu;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.75-78
    • /
    • 2005
  • This raper investigates the effect of curing temperature on strength development of concrete incorporating cement kiln dust(CKD) and blast furnace slag (BS) quantitatively. Estimation of compressive strength of concrete was conducted using equivalent age equation and rate constant model. An increasing curing temperature results in an increase in strength at early age, but with the elapse of age, strength development at high curing temperature decreases compared with that at low curing temperature. Especially, the use of 35 has a remarkable strength development at early age and even at later age, high strength is maintained due to accelerated pozzolanic activity resulting from high temperature. Whereas, at low curing temperature, the use of BS leads to a decrease in compressive strength. Accordingly, much attention should be paid to prevent strength loss at low temperature. Based on the strength development estimation using equivalent age equation, good agreements between measured strength and calculated strength are obtained.

  • PDF

An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting (전기발열시트 표면가열 양생공법의 현장적용 연구)

  • 김형래;조호규;김찬수;지남용
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

The designed compressive strength assurance method to the concrete subjected to cold weather at 28 days (한중환경하 타설된 구조체콘크리트의 결합재 종류별 관리재령 28일 설계기준강도 확보 기법)

  • Lee, Young-Jun;Hyun, Seung-Yong;Lee, Sang-Woon;Lee, Joung-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.47-48
    • /
    • 2018
  • The aim of the research is to suggest the compensating strength values depending on various managing periods of concrete based on the strength development model calculated with equivalent age method for OPC 100 % concrete. As a result, for 28 days of managing period, 6, and 3 MPa of compensating strength values were suggested when the temperatures were from 4 to 9℃, from 9 to 17℃, respectively. Additionally, for 42 days of managing period, 3MPa of compensating strength value was suggested when the temperature was from 4 to 10℃, and for 56 days of managing period, 3 MPa of compensating strength value was suggested when the temperature was from 4 to 5℃. Furthermore, for 28, 42, 56, and 91 days of managing periods, any compensating strength values were needed when the temperature were higher than 17, 10, 5, and 4℃, respectively.

  • PDF

Effect of the Replacement of Fine Particle Cement on Mechanical Properties of the Concrete (미분 시멘트의 치환율 변화가 콘크리트의 역학적 특성에 미치는 영향)

  • Choi, Sung-Yong;No, Dong-Hyun;Kim, Kyung-Min;Park, Sang-Joon;Kwan, O-Bong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.133-136
    • /
    • 2007
  • This study investigates mechanical properties of the concrete using fine particle cement which is manufactured by the pulverizing process. The variable factors are 3 types of W/C such as 40, 50, and 60%, 3 types of curing temperature such as 5, 20, and $35^{\circ}C$, and 5types of the replacement of the fine particle cement such as 0, 25, 50, 75, and 100%. The unit water content, S/a and amount of the SP and AE agents to secure the slump and air content is gradually increased in accordance with amount of replacement. It can be confirmed that the delay of the setting time depending on FC content is decreased corresponding to FC content, so the effect of the acceleration to the setting time is expected. The compressive strength corresponding to FC content is proportionally increased, and the growth is confirmed about $30{\sim}40%$ at a day in 50% of FC contents. However, the increase of the strength is gradually decreased in accordance with increasing age.

  • PDF

Effects of Blasting Vibrations of Physical Properties of Curing Concrete (발파진동이 양생 콘크리트의 물성에 미치는 영향)

  • Jeong, Dong Ho
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.1 no.1
    • /
    • pp.81-87
    • /
    • 1999
  • Effects of blasting vibrations on curing concrete have not been well studied. As a result, unrealistic and costly blasting vibration constraints have been placed on blasting when it occurs in the vicinity of curing concrete. To study the effects of blasting, concrete blocks of $30\times20\times20cm$ were molded and placed on the quarry Different sets of concrete blocks were subjected to peak vibrations of 0.25, 0.5, 1.0, 5.0, and 10cm/sec. The impulses of blasting vibrations were applied at thirty minutes intervals . Along with unvibrated concrete blocks, the vibrated concrete samples with 60.3mm in diameters were measured for elastic moduli, sonic velocity and uniaxial compressive strength. Test results can be summarized as follows : 1) The blasting vibrations between 6 and 8 hours after pour generally have exerted bad influences on the uniaxial compressive strength of the concrete 2) Under low vibration of 0.25cm/sec variations of the uniaxial compressive strength were not shown. As the magnitudes of blasting vibration increased, compressive strength of concrete decreased. But under the vibrations between 5 and 10cm/sec decreases in strength were almost same. 3) Physical properties of the p-wave velocity, Young's modulus, and Poisson's ratio appeared to decrease for the concrete blocks subjected to vibration for 6 to 8 hours.

  • PDF

A Case Study for Influence of Form-oil on Surface Condition of Steam-cured Concrete (증기양생 콘크리트 표면상태에 대한 박리제의 영향 사례연구)

  • Han, Sang Hoon;Yoon, Ju Yong;Hong, Ki Nam;Choi, Jae Wan;Lim, June Woo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.52-56
    • /
    • 2013
  • The purpose of this study is to evaluate the influence of form-oil on steam-cured concrete surface condition. Based, viscosity(high, medium, low) and flash point($26^{\circ}C$, $70^{\circ}C$) of form oil were considered as test variables. The digital image process method was applied for the extraction of air-void area from concrete surface. Test result showed that oil-based form oil reduced air-void by approximately 46% compared to water-based form oil, and the higher the viscosity was, the smaller air-void rate was. In addition, it was conformed that flash point of form oil had a considerable influence on the surface condition of steam-cured concrete.

Temperature History of the Slab Concrete applying Revised Bubble Sheet with Heating Cable (열선 매입과 열선 및 버블시트 조합의 개량형 버블시트를 포설한 슬래브 콘크리트의 온도이력 특성)

  • Jung, Eun-Bong;Ahn, Sang-Ku;Jung, Sang-Hyun;Ko, Kyung-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.23-25
    • /
    • 2013
  • In this study, the results are compared with the case of the concrete with embedded heating wire to verify the performance of the IB made in order to improve the workability and affordability, and to determine the effectiveness of early frost damage prevention. The IB was made using the 5W heating wire and layed on the upper surface of the concrete. The temperature was reduced to below 0℃ approximately within 24 hours, then approached the external temperature thereafter. On the other hand, when the 20W heating wire was used to make the IB and applied the same way, the temperature remained around -2 to 3℃ on the average even through the temperature was reduced to below 0℃, due to the heating wire with relatively large heating capacity. It appeared to reach 85% of the direct heating by embedding the heating wire relatively deeper in the concrete. However, it was determined that using the IB made with the 20W heating wire will prevent the early frost damage to some degree in -10℃.

  • PDF

Characteristics of Temperature History of Slab concrete by the Change of Hot wire Heat Capacity at -10℃ (-10℃ 조건에서의 열선 열용량 크기 변화에 따른 슬래브 콘크리트의 온도이력 특성)

  • Jung, Eun-Bong;Ahn, Sang-Ku;Jung, Sang-Hyun;Koh, Kyung-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.75-77
    • /
    • 2013
  • In this study, the characteristics of temperature history was evaluated for three hot wires with different capacity installed in slab concrete which are relatively thin. Results can be summarized as follows. First, for the case of material using 5W hot wire, all decreased to below zero at or around 24 hours. Similarly, the material using 20W hot wire decreased to 2℃ below zero at or around 80 hours but satisfied the accumulative temperature of 45° D·D at 7 days of material age. On the other hand, the case of 30W hot wire, the biggest capacity, showed the high temperature history of 5℃ in average at all areas except the corners. Thus, the target accumulative temperature was secured at or around the 3 days of material age. Considering the above, the initial damage by freezing can be prevented only if 20W or higher hot wires are used for the slabs at -10℃ of extremely low temperature environment.

  • PDF

A Study on Influences of Waterproofing Admixtures for Concrete on Self-Healing Properties of Hardened Cement Paste (시멘트페이스트 경화체의 Self-Healing 특성에 미치는 구체방수재의 영향)

  • Kim, Jae-Young;Byun, Seung-Ho;Ma, Sang-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.109-116
    • /
    • 2008
  • This study was performed to get information of self-healing mechanism in cement system and the influence of waterproofing admixtures for concrete on self-healing property. For testing, cement paste specimens cured for 7, 14 and 28 days were prepared and crushed into plate-shape pieces. Screened specimens with thickness not more than 1mm were covered with wet rags and cured in a plastic container for 7 and 28 days. After stopping hydration process of the specimens by treatment with acetone, the surfaces of specimens have been contacted with wet rags were analyzed by XRD, DSC, SEM and EDX. The analysis results showed that cement paste has self-healing property and this property is mainly affected by water. Self-healing in cement system is more effective and faster at an early stage of hydration as there is enough content of unreacted cement to make an additional hydration in this period. The results of this study also showed that waterproofing admixtures for concrete have a considerable effect on self-healing of cement pastes; i.e., they improved self-healing effect of cement and, especially, the specimen using admixture C has shown a lot of needle-like or fibrous hydration products which are estimated as ettringite. It is supposed that these ettringite products are effective to enhance self-healing in cement system.

Flexural Behavior of Hybrid Beam of Reduced Story Height (층고 절감을 위한 하이브리드 보의 휨 거동에 관한 실험적 연구)

  • Hong, Sung-Gul;Yang, Dong-Hyun;Jung, Jong-Hyun;Yim, Byung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.557-567
    • /
    • 2007
  • In underground parking lots of apartment housing, the story height is increased by $300{\sim}400mm$ because of various ducts for HVAC. In order to reduce this story height, this study proposed the 'hybrid beam', which is composed of PC beam with embedded steel beam and insitu concrete. The depth of the hybrid beam is reduced by 300 mm and then the steel beam is embedded over the length of reduced depth to compensate for the loss of strength. Then, we performed the large-scale structural tests on 9 specimens and investigated the flexural behavior of the specimens. The parameters of tests were the shape of steel beam section, the length of the reduced depth, the stage of construction, the effects of slab and shear connectors. The test results showed that the specimens, after the insitu concrete has cured, has the flexural capacity which exceeds the required design capacity regardless of other parameters. On the other hand, the specimens of construction stage do not have sufficient strength. Based on these results, it is thought that the proposed hybrid beam with reduced depth is applicable to the underground parking lots of apartment housing as long as the support is placed at construction stage.