• Title/Summary/Keyword: 콘크리트 압축강도 추정

Search Result 173, Processing Time 0.021 seconds

The Estimation of Compressive Strength of Ready-Mixed Concrete In the North Territory of Gyeonggi on the base of Mix Design (배합표에 의한 경기북부 레미콘의 압축강도 추정에 관한 연구)

  • 임창훈;지남용;조홍범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.979-984
    • /
    • 2003
  • Quality control of ready-mixed concrete is most important in the production step because, the performance of hardened concrete is revealed due to ready-mixed concrete. Hardened concrete has several properties physically. Above all things compressive strength of concrete has a greate effect in the design of structures, analysis, and durability. Compressive strength is simple predicted by w/c up to date, but there are some limits because different compressive strengths can be revealed in the same w/c. Therefore this study contributes to the quality control of ready-mixed concrete through statistical analysis for the relation between mix factors in mix design and compressive strength, predictable equation for compressive strength.

  • PDF

A Study on the Determination of Slip-up Time for Slip-Form System using Surface Wave Velocity (표면파 속도를 이용한 슬립폼 시스템 상승 시기 결정에 관한 연구)

  • Kim, Heeseok;Kim, Young Jin;Chin, Won Jong;Yoon, Hyejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.483-492
    • /
    • 2012
  • The early setting time of concrete is an important factor determining the slip up velocity of the slip-form system. Accordingly, need is for a technique evaluating the early setting time in order to secure the safety of the slip-form system and the construction quality of concrete. This paper intends to estimate the early setting time by evaluating the setting degree of concrete using surface wave velocity so as to determine the slip up time of the slip-form system. Penetration resistance test and compressive strength test are performed first to clarify the relationship between the early setting time of concrete and the compressive strength. Then, compressive strength test and ultrasonic wave test are conducted to examine the relation between the compressive strength and the surface wave velocity. Continuous wavelet transform is adopted to measure the surface wave velocity. Numerical analysis is carried out to demonstrate the appropriateness of the application of continuous wavelet transform. Based on these results, the propagation velocity of the surface wave required for the slip up of slip-form system is suggested. Finally, a reduced model test of the slip-form system is conducted to verify the feasibility of the proposed surface wave velocity for the determination of th slip up velocity.

A Study on the proposal of Strength Presumption Equation of Concrete Using Admixture by Nondestructive Testing (비파괴 시험에 의한 혼화재를 사용한 콘크리트의 강도 추정식 제안에 관한 연구)

  • Kim Jeong-Sup;Shin Yong-Seok;Kim Koung-Ok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.3 s.21
    • /
    • pp.59-66
    • /
    • 2006
  • This study aims to estimate strength approximate to actual concrete strength by presenting appropriate non-destructive strength estimation expression with admixtures such as fly ash, blast furnace slag and silica fume which are used as cement substitute and owing to theirs of cement owing to their equal conditions to blending characteristics of concrete used for domestic structures and their recyclable properties. As a result of comparing error rate of existing expressions and this estimation expression, error rate of this estimation is reduced compared to existing expressions and has higher reliability. When conventional concrete expression is applied to admixture concrete, error rate occurs and then this study suggests the following estimation expressions depending on types of admixture concrete.

Estimating Compressive Strength of High Strength Concrerte by Ultrasonic Pulse Velocity Method (초음파속도법에 의한 고강도 콘크리트의 압축강도 추정에 관한 연구)

  • Lim, Seo-Hyung;Kang, Hyun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.123-130
    • /
    • 2001
  • The purpose of this study is to suggest the non-destructive equation for the estimation of concrete strength by ultrasonic pulse velocity at the Age of 28day compressive strength of $600{\sim}1000kg/cm^2$. For this purpose, selected test variables were water-hinder ratio, replacement ratio of silica fume, binder content, maximum size of coarse aggregate and sand-aggregate ratio. From the results, the average increase or decrease of ultrasonic pulse velocity is 61m/sec for each 1% of moisture content. And the correlation equation between the ultrasonic pulse velocity and the compressive strength of concrete is as follows. $F_c=896.3V_p-3514$ ($R^2$ = 0.81) where, $F_c$ : compressive strength($kgf/cm^2$), $V_p$ : ultrasonic velocity(km/sec).

  • PDF

Estimation of Setting Time and Compressive Strength of Ternary Blended Concrete Applying Estimator (추정계를 활용한 3성분계 콘크리트의 응결 및 압축강도 추정)

  • Park, Jae-Woong;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.143-144
    • /
    • 2023
  • This study aimed to evaluate the feasibility of estimating the setting time and compressive strength in Ternary Blended Concrete(TBC) using Settimeter, Strength meter, and Hybrid meter. It was determined that the hardness values at the initial setting time and final setting time of Settimeter, Hybrid meter, and at the 5 MPa of Strength meter were not affected by the mixing ratio of TBC. However, future studies need to consider the errors caused by the instability of the measurement surface during condensation and the state of the measurement surface after hardening.

  • PDF

Assessment of Confining Effect of Steel and GFRP Jackets for Concrete (콘크리트 보강강판 및 GFRP 튜브의 구속효과 분석 및 평가)

  • Choi, Eunsoo;An, Dong Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.385-392
    • /
    • 2009
  • In this study, the confining effect of the proposed steel jackets and GFRP tubes for concrete was investigated. The new steel jacket differs from the existing steel jacket in terms of installation technique and behavior. Thus, it is necessary to assess its confining effect on concrete. Moreover, the method was compared to GFRP tubes to investigate its strong and weak points. The confining effect of the proposed steel jacket was shown to correspond with that presented in the previous researches. The GFRP jacketing method, however, does not show any confining effect in some cases, according to the tube thickness and concrete peak strength as such, the previous assessment equation cannot be used in such cases. Thus, in this study, a new method of assessing the peak strength of confined concrete was suggested, and the minimum thickness was determined to show the confining effect. Lastly, the ultimate strains of concrete that had been confined through the two methods were compared to assess their ductile behavior.

ing Durometer D type Evaluation of the possibility of Estimatingon of Setting Time and InitialEarly aAge Compressive Strength Using Durometer D type Durometer (D형 Durometer를 이용한 콘크리트의 미장용 모르타르의 응결시간 및 초기재령 압축강도 추정)

  • Han, Soo-Hwan;Han, Jun-Hui;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.57-58
    • /
    • 2021
  • This study is conducted an experiment to unifyprovide a method to estimate the method of measuring the condensationsetting time and estimating the initialearly age compressive strength using the existingD type ddurometer. into a single device and to adopt the best estimation guidelines of the estimator. As a result of the experiment, Test results indicated that it is analyzed that the use of D type Durometer attached with modified needle, which was designed to secure improved accuracy in setting and compressive strength, enables to estimate it is possible to estimate the condensationsetting time of mortar and estimate the compressive strength ofat early age. the initial age when the estimation No. 2 is adopted for the Durometer D type.

  • PDF

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.

A Study on Mechanical Characteristics of Masonry Structure Constructed by Clay Brick with Lime Mortar (점토벽돌과 석회모르타르를 사용한 조적구조의 역학적 특성에 관한 연구)

  • Yu, Hye Ran;Kwon, Ki Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.87-98
    • /
    • 2011
  • Clay bricks with lime mortar are recently popular since they are eco- and environment-friendly construction material being capable of air flow and moisture movement. However, there is little study on those of clay brick an lime mortar while relatively many researches on the structural characteristics of concrete bricks with cement mortar are available in Korea. Furthermore, the current Korean Building Code of masonry structures was established on the base of the Foreign Codes which does not reflect Korean masonry construction circumstance, such as material characteristics and section properties. To overcome these problems, experiments of masonry structures constructed using clay bricks with lime mortar were carried out to evaluate their structural characteristics such as, prism compressive strength, adhesive strength and diagonal tensile(shear) strength. Also this research compares the mechanical characteristics between clay bricks with lime mortar and concrete bricks with cement mortar to provide information that will be used for revisions of the domestic standards for masonry structures. As masonry structures constructed with clay bricks and lime mortar show different aspects over the ones constructed with concrete bricks and cement mortar, we suggest estimation equation of prism compressive strength and diagonal tensile strength on masonry structures constructed with clay bricks and lime mortar.

Microstructure and Properties of Mortar Containing Synthetic Resin using Image Analysis (이미지 분석을 활용한 합성수지 혼입 모르타르의 특성 및 미세구조 분석)

  • Lee, Binna;Min, Jiyoung;Lee, Jong-Suk;Lee, Jang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Commercial synthetic resins with great amount of hydrogen atoms were investigated for neutron shielding aggregates. Total three types of resins were considered in this study: high density polyethylene (HDPE), polypropylene (PP), and ultra molecular weight polyethylene (UPE). When these resins replaced 20, 40, 60 vol% of fine aggregates, mechanical properties were first evaluated including compressive and tensile strengths, and then image/microstructure analyses such as cross-section analysis, SEM, and X-ray CT were performed. The results showed that the compressive and tensile strengths decreased with the increase of replacement ratio of HDPE and PP, which was found through image analysis that it was closely related to the distribution of resins at the failure surface of test specimens. The strength reduction of UPE was quite small compared to HDPE and PP but it abruptly increased when the replacement level exceeded 60 vol%. The results of microstructure analyses indicated that the replacement level significantly affected the amount of air void so that it is critical to determine the reasonable amount of UPE to make cementitous materials for neutron shielding.