• Title/Summary/Keyword: 치과 보철물

Search Result 823, Processing Time 0.026 seconds

A Study on the Suitability of Cervical Margin According to Die Materials Used in Crown Prosthesis (치관보철물 제작시 사용되는 치형 재료에 따른 치경부 변인의 적합성에 관한 연구)

  • Lee, In-Kyu;Choi, Un-Jae;Chung, Hee-Sun
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.5-12
    • /
    • 2000
  • The gaps between the die margin worked and the casting body were measured with an optical microscope and compared after making crown prosthetic materials using three kinds of die material - dental stone, extra hard stone, epoxy resin - used in crown prosthesis. The results are as follows : 1. All the gaps between the cast cervical margin and the casting bodies were relatively good regardless of die materials used with the gaps under $50{\mu}m$, the allowable limit. 2. The cervical margin suitability of epoxy resin die was the highest among the three kinds of die material with the suitability value of $30.28{\pm}12.67$. 3. Among the four surfaces(buccal, lingual, mesial, distal) of all the casting bodies, buccal surface was the highest in the cervical margin suitability with the value of $25.93{\pm}15.51$.

  • PDF

Clinical Features of Oromandibular Dystonia (하악운동이상증의 임상양태)

  • Kang, Shin-Woong;Choi, Hee-Hoon;Kim, Ki-Suk;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.169-176
    • /
    • 2011
  • Oromandibular dystonia (OMD) is a form of focal dystonia that affects the masticatory, facial and lingual muscles in any variety of combinations, which results in repetitive involuntary and possibly painful jaw opening, closing, deviation or a combination of these movements. This study aimed to investigate clinical features and treatment type of OMD patients. By retrospective chart review, the study was conducted to consecutive OMD patients who visited a department of Oral Medicine and Orofacial Pain Clinic in a university dental hospital during Aug 2007 to Apr 2010. 78 OMD patients were identified with female preponderance (M:F=1:3.6) and a mean age of 72 years. Their mean duration of OMD was about 10 months. The most common chief complaints at the first visit was jaw ache, followed by uncontrolled, repetitive movement of the jaw and/or oral tissues, pain in the oral region(p=0.000). The most common subtype of OMD was lateral jaw-deviation dystonia, followed by combination and jaw-closing dystonia(p=0.001). While no apparent cause was recognized in over 60% of the OMD patients, peripheral trauma including dental treatment such as prosthetic treatment and extraction was the most frequently reported as precipitating factor(p=0.000). Medication was the 1st line therapy for our patients and anxiolytics such as clonazepam was given to most of them. Based on the results of this study, OMD is the disease of the elderly, particularly of women and causes orofacial pain and compromises function of orofacial region. Some patients considered dental treatment a precipitating factor. Dentists, therefore, should have knowledge of symptoms and treatment of OMD.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

Rheological properties of dental resin cements during polymerization (치과용 레진 시멘트의 유변학적 성질)

  • Lee, Jae-Rim;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.82-89
    • /
    • 2014
  • Purpose: The purpose of this study was to observe the change of viscoelastic properties of dental resin cements during polymerization. Materials and methods: Six commercially available resin cement materials (Clearfil SA luting, Panavia F 2.0, Zirconite, Variolink N, RelyX Unicem clicker, RelyX U200) were investigated in this study. A dynamic oscillation-time sweep test was performed with AR1500 stress controlled rheometer at $32^{\circ}C$. The changes in shear storage modulus (G'), shear loss modulus (G"), loss tangent (tan ${\delta}$) and displacement were measured for twenty minutes and repeated three times for each material. The data were analyzed using one-way ANOVA and Tukey's post hoc test (${\alpha}$=0.05). Results: After mixing, all materials demonstrated an increase in G' with time, reaching the plateau in the end. RelyX U200 demonstrated the highest G' value, while RelyX Unicem (clicker type) and Variolink N demonstrated the lowest G' value at the end of experimental time. Tan ${\delta}$was maintained at some level and reached the zero at the starting point where G' began to increase. The tan ${\delta}$and displacement of the tested materials showed similar pattern in the graph within change of time. The displacement of all 6 materials approached to zero within 6 minutes. Conclusion: Compared to other resin cements used in this study, RelyX U200 maintained plastic property for a longer period of time. When it completed the curing process, RelyX U200 had the highest stiffness. It is convenient for clinicians to cement multiple units of dental prostheses simultaneously.

Oral health status and treatment need of institutionalized elderly patients (노인요양시설에 있는 노인환자의 구강실태 및 치료수요도)

  • Yang, Soon-Bong;Moon, Hong-Suk;Han, Dong-Hoo;Lee, Ho-Yong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.455-469
    • /
    • 2008
  • Statement of problems: In the area of dental care, the institutionalized elderly have placed the most vulnerable state, and we cannot find their subjective need of dental treatment because of the physical and mental disabilities, But we have no basic investigation of their oral health conditions. Purpose: The aims of the current study were to investigate the oral health status of institutionalized elderly patients who are in the least benefited side of dental service, and to analyze their dental treatment needs. Material and methods: The survey of the oral status was carried out on 758 institutionalized elderly, and 212 elderly who was more than 65 years old from D dental office, and it was based on the Guidelines of Oral Health Research of year 2000 in Republic of Korea. Results and conclusion: The DMFT index of the institutionalized elderly appeared higher than that of the same ages in control group, and it increased with age. The number of residual teeth of the institutionalized elderly appeared lower than that of the same ages in control group, and it decreased with age (P < .05). The number of fixed partial denture in institutionalized elderly was lower than that of the same ages in control group (P < .05). The percentage wearing removable partial denture was not significant between the elderly in institutions and the control group, and was not different according to age between the two groups. The percentage of institutionalized elderly wearing complete denture appeared lower than that of the same ages in control group, and it increased with age. The percentage of institutionalized elderly needing complete denture was higher than that of control group, and the percentage of elderly needing complete denture on the maxilla was higher than that of the mandible. 16.35% of the institutionalized elderly was living without denture in spite of their fully edentulous state. The need for complete denture increased rapidly with age. The number of valued teeth and dental prostheses in shortened dental arch concept and number of occluding pairs of teeth of institutionalized elderly were lower than that of the control group (P < .05). In institutionalized elderly, the number of residual teeth, the number of fixed partial dentures, and the percentage wearing removable partial dentures were higher in the mandible, and the percentage wearing complete dentures was higher in the maxilla (P < .05). The rate of institutionalized elderly needing prosthodontic treatment appeared to be 67.82%, where the number of occluding pairs of teeth was less than 10. When it is difficult to evaluate the subjective need of dental treatment as with the institutionalized elderly, estimation using the number of occluding pairs of teeth can be a useful indicator that can project treatment needs. For the oral health care of institutionalized elderly, it is essential to increase the awareness of nurses and caregivers who take care of them, about the importance of the oral health. Since the average life span and number of residual teeth are increasing gradually, the welfare policy should be changed to implementing regular dental examinations, preservative treatment forms and oral health control of dentulous patients where the traveling-treatment system and visit system are supplemented. And principles should be set that the present denture project of edentulous patients should be done by specialists who'll also be responsible for postmanagement. Through this research of institutionalized elderly, the oral health status which is worsened by aging could be confirmed. And the interest and positive participation of dental society on the elderly should come first in order to solve the rising treatment needs of the elderly patients.

Study on the Infection Control and Dental waste Disposal in Dental Clinic Located in Seoul City (서울시 치과의원의 진료실 감염관리 및 폐기물 처리 실태 조사연구)

  • Kang, Jae-Kyoung;Kim, Eun-Sook;Kim, Kyung-Mi
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2002
  • This study was aimed to investigate the practice on the infection control and dental waste disposal in dental clinic. The data used in this study had been collected in 100 dental clinics located in Seoul city from August to October, 2001. It was shown that examination instruments, oral surgery instruments, and periodontal instruments were almost sterilization in dental clinic. It was high in the recognition of individual protection but it was low in the degree of practice. Therefore, the practice in infection control is very important to dental team for safety of patients and operators.

  • PDF

Dimensional Changes of Ceromer Crown by Water Absorption (치과용 심미수복재료 세로모에서 수분흡수와 체적 변화에 관한 연구)

  • Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • Statement of problem: The increasing demand for esthetic restorations has been required developing new materials for tooth colored restoration. Ceromer(Ceramic Optimized Polymer) has some advantages over porcelain, and has gained increasing popularity in restorative dentistry. However, there is little information on the dimensional changes in a clinical restoration in moist conditions. Purpose: This study examined the dimensional changes in Ceromer restorations with a clinical crown shape that were fabricated in a clinical manner. Material and methods: The crowns for the maxillary central incisor were fabricated with two Ceromers($BelleGlass^{(R)}$ and $Targis^{(R)}$) using a similar clinical restoration manufacturing technique. A total of twenty specimens were prepared and immersed in distilled water at room temperature to allow for water absorption. The weight, height and width were measured at 24, 72 and 168 hours. The accumulated ratios of the changes were calculated and evaluated using a paired t-test and an independent independent t-test. Results: The dimensions and weight increased with increasing soaking time. $Targis^{(R)}$ showed significant differences in height and weight between 24 hours and the other times(P<.05). $BelleGlass^{(R)}$ showed significant differences in width and weight between 24 hours and the other times. The two materials showed different changing patterns of the dimensions but there were no statistically significant differences between them. Conclusion: The dimensions and weight of the Ceromer restorations were changed by water absorption. The clinical crown shaped specimen showed more complicated dimensional changes than the simplified specimens.

Antimicrobial activity of dental polishing bur material with fluoride ion (불소이온을 함유한 연마용 버 재료의 항균력 연구)

  • Jeong, Insun;Kim, Ji-Hyun;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • Purpose: The purpose of this study is to evaluate the antimicrobial activity on the dental bur with fluoride for S. mutans. Materials and methods: 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, 1,450 ppm fluoride ion is added to a specimen. S. mutans was incubated for 24 hours, the number of S. mutans were counted. Kruskal-Wallis and MannWhitney analysis were used SPSS 25.0 (IBM SPSS 25.0, Chicago, IL, USA). Results: The mean S. mutans counts of 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, and 1,450 ppm were 374.0 ± 12.6, 251.0 ± 66.7, 111.4 ± 35.6, 41.6 ± 11.7 and 13.2 ± 4.6, respectively. All groups except the control and 300 ppm showed statistically significant. Conclusion: Thus, more than 500 ppm fluoride ion showed the statistically significant antimicrobial activity. 1,450 ppm group showed the highest antimicrobial activity. This study showed the clinical possibility for dental caries protection and antimicrobial activity of dental bur.

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.