• Title/Summary/Keyword: 측모 두부 방사선 계측치

Search Result 54, Processing Time 0.02 seconds

Comparison of analysis of the lateral cephalogram and analysis of lateral facial photograph (측모 두부방사선계측사진 분석과 측모 사진 분석의 비교)

  • Lim, Sung-Hoon;Cho, Ju-Young;Choi, Gab-Lim;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.74-83
    • /
    • 2006
  • Analysis of lateral cephalometric radiograph (cephalogram) has been used routinely to evaluate skeletal and dental relationships, but analysis of the lateral facial photograph has not been used frequently for evaluation of skeletal relationships. As concerns about harm of X-ray irradiation increases, this study was planned to evaluate the possibility of substituting analysis of the lateral cephalogram with analysis of the lateral facial photograph by comparing these two analyses. According to the ANB values from cephalometric analysis, subjects were divided into three groups: Class I malocclusion group (n=32). Class II malocclusion group (n=32), and Class III malocclusion group (n=31). After measurements of angles indicating horizontal and vertical relationships of the maxilla and mandible on the lateral cephalograms and photographs, differences between Class I, II and III groups were evaluated. To evaluate the similarity between two similar values in the cephalograms and photographs, t-test using standardized variable Z and correlation analysis were performed in the Class I malocclusion group. The results showed that 1) SnN'Pg' on the photograph can be used to evaluate the antero-posterior relationship of the maxilla and mandible (ANB), 2) N'-Sn/Sn-Pg' on the photograph can be used to evaluate facial convexity (NA/APg), 3) Sn-Tra-Me' on the photograph can be used as a measurement similar to FMA. In conclusion, partly substituting lateral cephalogram analysis with lateral facial photograph analysis was possible in the evaluation of the maxilla and mandible.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograms in linear and angular measurements (3차원 두부방사선규격사진의 정확성에 관한 연구 -실제 계측 및 측모 두부방사선 규격사진 계측과의 비교-)

  • BAE, Gi-Sun;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.129-140
    • /
    • 1997
  • Conventional cephalometrics have inherent errors because their evaluation is performed in two-dimension for threedimensional object. To compensate these errors, three-dimensional cephalograms - derivation of three-dimensional data from conventional lateral and postero-anterior cephalograms - were developed. In this study, the accuracy and precision of three dimensional cephalograms were determined by means of 10 linear and 12 angular measurements on 36 acrylic skull models and by the comparison of conventional lateral cephalograms. The results were as follows 1. Mean difference between three-dimensional cephalograms and actual models in linear measurements was $0.94{\pm}0.62mm$ and mean rate of magnification of three-dimensional cephalograms was $100.31{\pm}0.91%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in linear measurements(${\alpha}=0.1$). 2. Mean difference between conventional lateral cephalograms and actual models in linear measurements was $6.44{\pm}1.48mm$ and mean rate of magnification of lateral cephalograms was $106.99{\pm}1.45%$. There were statistically significant differences between lateral cephalograms and actual models in linear measurements(P<0.005). 3. Mean difference between three-dimensional cephalograms and actual models in angular measurements was $1.22{\pm}0.82^{\circ}$ and mean rate of magnification of three-dimensional cephalograms was $105.71{\pm}12.07%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in angular measurements(${\alpha}=0.1$). 4. Mean difference between conventional lateral cephalograms and actual models in angular measurements was $1.70{\pm}0.94^{\circ}$ and mean rate of magnification of lateral cephalograms was $106.35{\pm}15.70%$. There were no statistically significant differences between lateral cephalograms and actual models in angular measurements(${\alpha}=0.1$). There were similarity between three-dimensional and lateral cephalograms in angular measurements.

  • PDF

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

A comparative study of guiding methods for natural head posture in cephalometrics (두부방사선규격사진 촬영 시 유도방법에 따른 자연두부자세의 차이 및 재현성에 관한 연구)

  • Song, Jin-Myoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.341-350
    • /
    • 2005
  • The Purpose of this study was to compare the degree of vortical head rotation and to evaluate the reproducibility of natural Head posture (NHP) according to two guiding methods, the head posture aligner (HPA) method and the solf balance posture (SBP) method. The subjects consisted of 30 adults. On the first day. lateral and frontal cephalometric radiographs were obtained through the two guiding methods. One mouth later. lateral and frontal cephalometric radiographs were obtained again through both guiding methods. The degrees of vertical head rotation of both guiding methods were compared and the reproducibility was evaluated for each guiding method. A comparison of the degrees of vortical head rotation for the two methods revealed that the vertical head posture was lower in the SBP method than in the HPA method by an average of $2.79^{\circ}$. All measurements obtained using the HPA and SBP methods with a time interval of one north did not show any significant difierence in lateral and frortal cephalometric radiographs. The results of the present study suggest that the SBP method may be used as an alternative to the HPA method in case the HPA method can not be applied.

CEPHALOMETRIC ANALYSIS FOR CHILDREN WITH NORMAL OCCLUSION IN THE PRIMARY DENTITION (정상교합을 가진 유치열기 아동의 두부방사선 계측학적 연구)

  • Suh, Moon-Sun;Son, Heung-Kyu;Baik, Hyung-Sun;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.109-118
    • /
    • 2005
  • In the field of pediatric dentistry, comparison and analysis of cephalogram values of children are important fir evaluation of growth and development, and are essential to evaluate the craniofacial form and growth pattern for early diagnosis of malocclusion. For this, cephalographic norm values are important, but not many studies on the primary dentition exist. To compare the past norm values of normal occlusion in the primary dentition with current norms, preschool children, 4 to 5 years of age, with normal occlusion in the primary dentition who visited our hospital were examined. Among these children, 46 children with normal facial form and developmental status were chosen for evaluation of cephalogram values. The following results were as follows: 1. For skeletal values, the angular values showed no significant differences between males and females, and the linear values were generally greater in males than females. 2. SNA was $81.3^{\circ}$, SNB was $76.6^{\circ}$ and ANB difference was $4.7^{\circ}$. 3. The ratio for Mandibular body length to Anterior cranial base length was 0.9 : 1 for both male and female and the ratio for posterior facial height to anterior facial height was 61.4 % for male, 62.0 % for female. 4. For dental values, IMPA was $84.2^{\circ}$ and UA to SN was $90.8^{\circ}$. 5. The upper lip to Ricketts esthetic line was positioned 2.6 mm anteriorly, and the lower lip to Ricketts esthetic line was positioned 2.5 mm anteriorly.

  • PDF

The effect of CR-CO discrepancy on cephalometric measurements in Class III malocclusion patients (골격성 III급 부정교합자에서 중심위 변위가 두부 방사선 계측치에 미치는 영향)

  • Park, Yang-Soo;Kim, Jong-Chul;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.255-265
    • /
    • 1996
  • The purpose of this study was to investigate if there were a significant difference between cephalometric measurements of mandibular position derived from a centric occlusion tracing compared to those of a converted centric relation tracing in the Class III malocclusion. The sample consisted of 25 Class III malocclusion and 25 normal occlusion persons who had no orthodontic treatment. The records included an lateral cephalometrics in centric occlusion, centric relation and centric occlusion bite registration and diagnostic casts mounted on the SAM II articulator in CR. The amount of CR-CO discrepancy of condyle was recorded using a MPI(Mandibular Position Indicator, MPI $200^{(R)}$, Great Lakes Orthodontics, USA). The conversion of the CO cephalogram to CR using the MPI readings was performed on the Conversion work sheet. Measures of mandibular position were chosen for the purpose of this study. The comparison of the difference between CO and CR cephalometric measurements in the normal occlusion and Class III malocclusion group were studied. The results were as follows: 1. In the features of CR-CO discrepancy of the condyle, the condyle was displaced posterior and inferior when the teeth were in centric occlusion. The horizontal component(${\Delta}X$) in Class HI malocclusion group was greater than the vertical component(${\Delta}Z$) and also greater than the horizontal component(${\Delta}X$) in normal occlusion group. There was no statistically significant correlation between MPI measurements and the groups of normal occlusion and Class III malocclusion group. 2. In the comparison of the cephalometric measurements in each group, Normal occlusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity and ODI. Class HI malocclusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity, ODI, SNB, APDI, L1-FP and it had more significance than the normal occlusion group. 3. The Value of cephalometric measurements was significantly different between CO and CR but there were no differences between the groups of normal occlusion and Class III malocclusion. The results of this study suggest that if the discrepancies are greater than the amount of normal displacement from clinically captured centric relation, centric relation should be considered as the starting point for proper diagnosis and treatment planning.

  • PDF