• Title/Summary/Keyword: 최소이격거리

Search Result 87, Processing Time 0.019 seconds

Minimized Distance of the Current Electrode in the Measurement of Ground Resistance (접지저항 측정에 있어서 전류전극의 최소 이격거리)

  • Lee, Sang-Mu;Kang, Young-Heung;Yang, Jun-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.68-73
    • /
    • 2006
  • As in the measurement of ground resistance by using the 3 point fall-of-potential method, it is known that the distance of current electrode should be at the point of showing the plateu on the potential curve. But the problem is that it my be practically impossible to meet the condition in actual sites. For solving such a situation, this paper provides the least distance of current electrode according to the analysis for the test-field measurement showing that it is feasible to measure the ground resistance in the two in current electrode distance as the length of driven-rod type electrode and the some district length of mesh electrode.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

An Analytical Approach to Collision Avoidance between Two Encountering Ships (교항하는 두 선박간의 충돌회피에 관한 해석적 접근)

  • Park, Jeong-Hong;Kim, Jin-Whan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.21-22
    • /
    • 2011
  • In this study, an analytical algorithm for collision avoidance is proposed, which is applicable to designing collision avoidance maneuvers for two encountering ships. The minimum separation distance is defined and an appropriate maneuver sequence is computed for safe and effective collision avoidance. Two approaches: 1) collision avoidance through speed change and 2) collision avoidance through heading change, are considered, and the initiation point of the avoidance maneuver is computed analytically using the geometric configuration of the two encountering ships. To verify the feasibility of the proposed algorithm, numerical simulations are carried out using a set of ship-to-ship encountering scenarios.

  • PDF

A Study on the Prevention Effect of Lateral Movement by Finite Element Analysis (유한요소해석에 의한 측방이동 방지효과에 대한 연구)

  • Park, Choon-Sik;Rho, Tae-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.71-82
    • /
    • 2018
  • This study presents a reasonable and economical DCM reinforcement length for the various factors (the embankment height, the distance from the embankment to the underground structure, the depth of the soft ground, and the compression index and the swelling index of the soft ground) that affect the stability of the structure due to lateral movement. Based on these results, we analyzed each factor's degree of influence and figured out which factor influenced the lateral movement most. The cross section of the embankment on the soft ground was modeled by using the Finite Element Program and reinforced with DCM. The results show that the increase rate of the reinforcement length with the increase of the embankment height is about 9~50%, the increase rate of the reinforcement length with the depth of soft ground is about 13~30%, and the increase rate of the reinforcement length with increasing compression index is about 3~25%. In addition, the influence of each factor on each other was analyzed. As a result, among the separation distance, the compressive index and the maximum to minimum slope ratio of the reinforcement length of the embankment height, the separation distance was the largest for the depth of soft ground. As the depth of the soft ground increases, the ratio of the maximum to minimum slope of the reinforcement length according to the embankment height is 3.75, the ratio of the maximum to minimum slope of the reinforcement length according to the spacing distance is 4.3, and the ratio of maximum to minimum slope according to compression index is 2.5. From these results, it is confirmed that the three factors are greatly affected by the depth of soft ground.

Study on the Establishment of the Separation Distance between Anchored Ships in Jinhae Bay Typhoon Refuge (진해만 태풍 피항지 정박 선박간 이격거리 설정에 관한 연구)

  • Won-Sik Kang;Ji-Yoon Kim;Dae-Won Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.338-347
    • /
    • 2023
  • Jinhae Bay, characterized by frequent runaway ships and strong winds during typhoon attacks, poses a high risk of maritime accidents such as ship collisions and groundings. This study aims to determine a safe separation distance between ships in the Jinhae Bay anchorage, considering the unique environmental characteristics of the Korean sea area. Analysis revealed that an average of 100-200 ships anchor in the typhoon avoidance area in Jinhae Bay during typhoon attacks, with approximately 70% of ships experiencing anchor dragging owing to strong external forces exceeding 25 m/s wind speeds. In this study, we analyzed and presented the separation distances between ships during anchoring operations based on domestic and international design standards, separation distances between ships used as actual typhoon shelters in Jinhae Bay, and appropriate safe distances for ships drifting under strong external forces. The analysis indicated that considering the minimum criteria based on the design standards and emergency response time, a minimum safe distance of approximately 400-900 m was required. In cases where ample space was available, the separation distance was recommended to be set between 700 to 900 m. The findings of this study are anticipated to contribute to the development of guidelines for establishing safe separation distances between ships seeking refuge from typhoons in Jinhae Bay in the future.

Compatiblility analysis between DTV and WRAN systems (DTV와 WRAN 시스템 사이의 양립성 분석)

  • Choi, Jae-Hyuck;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • In this paper, we analyze an effect co-existence between digital television (DTV) and 802.22 wireless regional area network (WRAN) systems. We set DTV as an interfering system and 802.22 WRAN as a victim system. When they share the same spectrum, we calculate the minimum separation distance. In analysis, we compare a minimum coupling loss (MCL) with a transmission loss (TL) for determining whether there exists the potential interference or not. The minimum separation distance is determined when the TL is larger than the MCL. In this case, the DTV system does not affect any harmful effect to 802.22 WRAN.

A Coexistence Study of Low-power Short-range Wireless Network and Incumbent Service in the 6GHz band (6GHz 비면허 대역의 저전력 근접 무선통신과 기존 무선업무와의 공존 연구)

  • Kim, Seung-Nam;Lee, Il-Kyoo;Sung, Joo-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1074-1081
    • /
    • 2021
  • It has recently been noticed that the headway of unlicensed wireless technology is necessary as user's demands of wireless tech increase and the development of high-speed data service by using low-power short-range wireless network is needed. Hence, it is inevitable to study sharing and coexistence for broadband spectrum of diverse unlicensed application with wide bandwidth. In this paper, an interference examination between unlicensed WiFi (Wireless Fidelity) in the 6GHz and OB (Outside Broadcasting) system which is an incumbent service in the same frequency band was conducted and it suggests separation distance for the coexistence. Thus, MCL (Minimum Coupling Loss) and MC (Monte Carlo) methods were used to set up interference scenarios for the interference analysis and compute the separation distance between two systems according to the same frequency band and frequency separation.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.