• Title/Summary/Keyword: 체중이동

Search Result 205, Processing Time 0.029 seconds

Aspirin Reduces Acute Lung Injury in Rats Subjected to Severe Hemorrhage (Aspirin이 출혈성 쇼크로 인한 급성 폐손상에 미치는 효과)

  • Shin, Tae Rim;Lee, Dong Uk;Park, Yoon-Yub
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.5
    • /
    • pp.522-531
    • /
    • 2003
  • Background : Hemorrhagic shock and trauma are two of the most common causes of acute lung injury. The activation of cyclooxygenase is one of the important causes of acute lung injury. This study investigated the effect of aspirin, a well-known cyclooxygenase inhibitor, on severe hemorrhage-induced acute lung injury in rats. Methods : The hemorrhagic shock was induced by withdrawing blood; 20ml/kg of B.W., through the femoral artery in 5 min. The mean arterial pressure was recorded through the femoral artery on a polygraph. Results : In the present investigation, the lung tissue myeloperoxidase activity, protein contents and leukocyte counts, in bronchoalveolar lavage fluid, increased significantly 2 and 24 h after the hemorrhage induction. Although the decreased mean arterial pressure spontaneously recovered, acute lung injury occurred after severe hemorrhage. These changes were effectively prevented by a single intravenous injection of aspirin (10 mg/kg of B.W.) 30 min before the hemorrhage. Conclusion : These results suggest that severe hemorrhage-induced acute lung injury is mediated, in part, by the activation of cyclooxygenase. Furthermore, pretreatment of aspirin in acute lung injury-prone patients, or prophylactic treatment of aspirin to the patients with precipitating conditions, could be helpful in the prevention of acute lung injury.

The Effect of Height of Cane for Health Promotion on Mobility of Patients with Stroke (뇌졸중 환자의 건강증진을 위한 지팡이 높이가 보행과 체중지지율에 미치는 영향)

  • Seo, Tae-Hwa;Kwon, Sang-Min;Jeong, Yeon-Woo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.1
    • /
    • pp.207-215
    • /
    • 2019
  • This study examines the effect of the height of cane that hemiplegic patients due to stroke use on their plantar pressure in standing position, gait speed. The study suggests a new standard for appropriate cane height that considers the change of average height of population. Research subjects included 12 patients hospitalized in S Medical Care Hospital located in Gwangju Metropolitan City in South Korea who were diagnosed with stroke. Group A uses a cane of the height of the greater trochanter of femur, group B uses a cane of 5cm above the height of the greater trochanter of femur, and group C is a cane of 10cm above the height of the greater trochanter of femur. In the study result, non-affected side plantar pressure and affected side plantar pressure showed a significant difference among the cases where the cane height was the same as the A group, B group, C group. In the post-hoc analysis result, a significant difference was observed between the case of A group and C group. Gait speed showed no significant difference among the case of the A group, B group, C group. The asymmetry of the stroke affects not only the posture but also the walking that is related to daily life. Changes in the height of the cane did not affect walking speed. The change in the height of the cane showed a change in the weight support ratio, which is thought to have a positive effect on the asymmetry. In future clinical setting, this study result will be able to provide fundamental data regarding the cane height in the standing or walking therapy for hemiplegic patients due to stroke with cane application.

Gonad Ontogeny in Relation to Somatic Growth in the Brown Croaker Miichthys miiuy (Basilewsky) (민어, Miichtys miiuy (Basilewsky)의 성장과 연관된 생식소 발달)

  • Park, In-Seok;Seol, Dong-Won;Im, Soo-Yeon;Park, Min Ouk;Hur, Woo June;Cho, Sung Woan;Song, Young-Chae;Kim, Jea-Soo;Jo, Hyo-Jae;Noh, Choong Hwan;Choi, Hee Jung
    • Korean Journal of Ichthyology
    • /
    • v.19 no.2
    • /
    • pp.107-111
    • /
    • 2007
  • Sex differentiation of the brown croaker Miichthys miiuy (Basilewsky) is described from hatching to the 120th day post-hatching (dph) (water temperature $24^{\circ}C$). Primordial germ cells (PGCs) were observed on the 20th dph (10.4 mm total length (TL), 0.14 g body weight (BW), and began to protrude into the peritoneal cavity from the 40th dph (19.4 mm TL, 0.39 g BW). On the 65th dph (31.3 mm TL, 0.93 g BW, $1,560D^{\circ}$ (degree-days)), initial ovarian differentiation was identified by the PGCs with condensed chromatin, and their transformation into meiotic oocytes. By the 120th dph (4.60 mm TL, 1.38 g BW, $2,880D^{\circ}$), the oocytes were in the perinucleolus stage and had increased from 20 to $40{\mu}m$ in diameter. While ovaries gradually grew after sex was differentiated, testes continued to multiply from the 65th dph. On the 80th dph (37.9 mm TL, 1.39 g BW, $1,920D^{\circ}$), the beginning of testis lobule formation was indicated by the occurrence of spermatogonial cysts enveloped by somatic cells in some of the testes. On the 120th dph, the testis lobules of some of the fish contained all germ cell stages through to the spermatocytes. Therefore, the sex differentiation type of the brown croaker is identified as gonochoristic.

Correlation Analysis of Factors Affecting the Collimator Size used during Lumbar Spine Lateral Examination in Digital Radiography System (디지털 방사선 장비에서 요추 측면 검사 시 사용되는 조사야 크기에 영향을 미치는 요인의 상관관계 분석)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2024
  • The purpose of this study was to suggest an appropriate collimation size and central X-ray incidence point by analyzing the correlation between the collimation size used in lumbar lateral examination and factors affecting the collimation size. the lumbar lateral examination results of 148 patients suitable for the purpose of this study were analyzed. The measurement method was to set the total horizontal width shown in the image to the size of the irradiation field(collimation) used during the examination. The distance connected vertically from the end of the dorsal field to the apophyseal joint of the third lumbar vertebra(AJD), the distance from the dorsal end of the image field to the center of the body of the third lumbar vertebra(BD), and the distance from the end of the dorsal field of the image to the center of the pedicle of the third lumbar vertebra(PD). The distance was measured. For comparative analysis of the mean values of dependent variables according to gender, age, height, weight, and body mass index, the mean values were compared using the independent samples t test and one-way ANOVA. For post hoc analysis, duncan was used. The correlation between independent and dependent variables was analyzed using Pearson correlation analysis. In this study, statistical significance was set at a p value of 0.05 or lower. The average value of the collimation size during the lumbar spine lateral examination was 252.45 mm, AJD was 102.11 mm, BD was 141.17 mm, and PD was 119.73 mm. The mean values of collimation size, AJD, BD, and PD were larger in men than in women, but statistical significance for the difference in mean values by gender was found only in BD (p<0.05). There was a slight difference in the mean value of each group according to age, but there was no statistical significance (p>0.05). The collimation size and mean values of AJD, BD, and PD according to height, weight, and body mass index differed depending on the independent variables, and the differences were all statistically significant (p<0.05). As a result of the correlation analysis, field size and AJD, BD, and PD showed no correlation with gender and age, a weak positive correlation with height, and a medium positive correlation with weight and body mass index. The results of this study showed that CS was correlated with height, weight, and BMI during lumbar lateral examination. If the entrance point of the central X-ray is moved to the appophyseal joint by considering weight and BMI when adjusting the collimation size in clinical practice, it is expected that the collimation size can be reduced bu about 5%.

The effects of ipriflavone on the periodontal reorganization following experimental tooth movement in the rat (Ipriflavone 투여가 백서의 실험적 치아이동 후 치주조직의 재형성에 미치는 영향)

  • Min, Ji-Hyun;Cho, Jin-Hyoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.347-357
    • /
    • 2008
  • Objective: The purpose of this study was to examine the effect of ipriflavone on periodontal reorganization and prevention of relapse following tooth movement. Methods: Orthodontic rubber bands were inserted between the first and second maxillary molars of 27 white male rats for 3 weeks for experimental tooth movement. From one day before the removal of orthodontic rubber band, ipriflavone was administered 50 or 400 mg/kg daily in each experimental group whereas carboxymethyl cellulose solution was administered in the control group. They were sacrificed at the 5, 10, and 15th day from the day of removal of orthodontic rubber bands. The amount of relapse was evaluated by measuring the interdental space, and the extent of periodontal reorganization was compared through histological examination. Results: In case of ipriflavone administration, the amount and velocity of relapse was less and slower compared to the control group. In addition, the ipriflavone group showed more rapid periodontal reorganization compared to the control group. Conclusions: The results of the present study suggest that ipriflavone administration can be used effectively in the prevention of relapse following orthodontic tooth movement through the acceleration of periodontal reorganization.

Medial Longitudinal Arch Balanced Analysis of the Calibration (종족궁 내측아치 지지에 따른 균형능력 분석)

  • Kim, Seonchil;Lim, Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.51-56
    • /
    • 2014
  • We analyzed how insole affects the dynamic stability and the balance while a body moves or stops. Specially we've sorted out variations of individual balance ability while we make a longitudinal arch stop artificially as a usual situation(just standing and putting one's weight). We found ten men and girls each with suitable feet for our experimentation as the subject of investigation and made individual insole for them by measuring medial longitudinal arch. Then we compared before and after movement of the power point of application and a pattern of COP using the Tetrax balance equipment. We found out it is better for balance ability when we wear insoles. It turned out to be helpful for increasing balance ability of body to use insole which supports medial longitudinal arch of longitudinal arch well.

Adaptation of Customized Measurement of Stride Length in Smart Device (스마트 기기를 활용한 보행속력에 따른 맞춤보폭의 적용)

  • Lee, Byung Mun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.35-43
    • /
    • 2013
  • Exercise such as walking is helpful to manage one's own weight and to counter life habit diseases such as obesity. Calorie consumption is usually calculated based on the distance walked. One way to measure the distance is by using steps and stride length. Most pedometers, including some applications in smart devices, are inaccurate, because they use a common value as the average stride length, even though each person has a different stride length. Moreover, the stride length differs depending on the walking pace, which will further increase the error. To address this, in this paper, I classify paces into three categories. Following that, I introduce a customized measurement of stride length, which is calculated based on the stride length corresponding to each pace category after obtaining x, y, z values from a 3-axis accelerometer in the smart device. In addition to this, I developed an application running on the smart device designed for the proposed measurement of stride. I have conducted three experiments for the assessment of the proposed measurement. In conclusion, I confirmed the effectiveness of this system.

The Effect of Splinting Methods on the Rearrangement of Periodontal Fibers after Tooth Movement in Adult Dogs (치아이동 후 고정방법이 성견 치주인대 섬유의 재배열에 미치는 영향)

  • Lee, Kr-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.825-837
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of splinting methods on the rearrangement of periodontal fibers after experimental tooth movement. Orthodontic force was applied by placing closed coil spring between upper third incisor and canine in seven dogs, weighing 20 kg or more. After 3 weeks of force application, 0.0215 inch multistrand wire and polyethylene ribbon were bonded to each side, as a flexible and rigid splinting respectively in 6 experimental animals. The remaining one served as a control. Each two animals were sacrificed at 4, 8 and 12 weeks after splinting respectively and prepared histologically for hematoxylin-eosin and Masson's trichrome staining. The results of this study were obtained as follows: 1. After tooth movement, periodontal space was narrowed and periodontal titers were thick on pressure side while elongated fibers were observed on tension side. 2. After 4 weeks of retention, the rearrangement of periodontal fibers was observed in the flexible splinting group, but not in the rigid splinting group. 3. After 8 weeks of retention, the rearrangement of periodontal titers was observed in both groups, but the difference could not be detected between two groups. 4. During the retention period, the rearrangement of periodontal fibers was faster in tension side than in pressure side. These results show that the rearrangement of periodontal fibers is also obtained by rigid splinting after tooth movement. It is suggested that the rigid splinting by polyethylene ribbon can be used as a way of postorthodontic retention.

  • PDF

Movement of Herbicide Pretilachlor in Plants and Soils (식물체(植物體) 및 토양중(土壤中)에 있어서 제초제(際草劑) Pretilachlor의 이동특성(移動特性))

  • Ma, Sang-Yong;Moon, Young-Hee;Ryang, Hwan-Seong
    • Applied Biological Chemistry
    • /
    • v.30 no.4
    • /
    • pp.351-356
    • /
    • 1987
  • This study was conducted to investigate the absorption and translocation of pretilachlor [2-chloro-2, 6-diethyl-N-(n-propoxyethyl)-acetanilide] in plants and to evaluate the mobility in soil using the $^{14}C-or$ non-labelled compound in laboratory. Rice plant(Oryza sativa L.) was very tolerant to pretilachlor. Echinochloa crus-galli P. Beauv. was completely controlled by pretilachlor at 60g a.i./10a. At the 120g a.i./l0a, growth of Cyperus serotinus Rottb. and Sagittaria pygmaea Miq. was inhibited by 75% and 25%, respectively. The growth inhibition depended on absorbed amount of $^{14}C-pretilachlor$. The greatest concentration of $^{14}C$ was found in E. crus-galli, whereas the lowest was determined in rice plant. The rate of absorption and translocation in E. curs-galli was faster than in rice plan. Pretilachlor moved to 6cm deep in sandy clay loam, clay loam and loam soils, but to 10cm in sandy loam soil. In the soils herbicide-treated layer was found 0 to 2cm profile.

  • PDF

Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users (휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발)

  • Jang, Kyung-Bae;Lee, Kyeong-Wan;Koo, Do-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.