The Effect of Splinting Methods on the Rearrangement of Periodontal Fibers after Tooth Movement in Adult Dogs

치아이동 후 고정방법이 성견 치주인대 섬유의 재배열에 미치는 영향

  • Lee, Kr-Heon (Department of Orthodontics, College of Dentistry, Chonnam National University) ;
  • Hwang, Hyeon-Shik (Department of Orthodontics, College of Dentistry, Chonnam National University)
  • 이기헌 (전남대학교 치과대학 교정학교실) ;
  • 황현식 (전남대학교 치과대학 교정학교실)
  • Published : 1997.10.01

Abstract

The purpose of this study was to evaluate the effect of splinting methods on the rearrangement of periodontal fibers after experimental tooth movement. Orthodontic force was applied by placing closed coil spring between upper third incisor and canine in seven dogs, weighing 20 kg or more. After 3 weeks of force application, 0.0215 inch multistrand wire and polyethylene ribbon were bonded to each side, as a flexible and rigid splinting respectively in 6 experimental animals. The remaining one served as a control. Each two animals were sacrificed at 4, 8 and 12 weeks after splinting respectively and prepared histologically for hematoxylin-eosin and Masson's trichrome staining. The results of this study were obtained as follows: 1. After tooth movement, periodontal space was narrowed and periodontal titers were thick on pressure side while elongated fibers were observed on tension side. 2. After 4 weeks of retention, the rearrangement of periodontal fibers was observed in the flexible splinting group, but not in the rigid splinting group. 3. After 8 weeks of retention, the rearrangement of periodontal titers was observed in both groups, but the difference could not be detected between two groups. 4. During the retention period, the rearrangement of periodontal fibers was faster in tension side than in pressure side. These results show that the rearrangement of periodontal fibers is also obtained by rigid splinting after tooth movement. It is suggested that the rigid splinting by polyethylene ribbon can be used as a way of postorthodontic retention.

실험적 치아이동 후 보정기간 동안 고정방법이 치주인대 섬유의 재배열에 미치는 영향을 알아보기 위하여, 체중 20kg 내외의 성견에서 상악 제 3절치와 견치 사이에 견인 스프링을 이용하여 120 gm의 교정력을 3주간 가한 후 좌측에는 유연성 고정장치로 0.0215 인치 multistrand wire를, 우측에는 견고성 고정장치로 폴리 에틸렌 리본을 레진 접착제로 각각 장착한 다음 4주, 8주, 또는 12주 후 희생시켜 치주조직의 변화를 방사선 사진, 광학 현미경 관찰을 통하여 분석한 바 다음과 같은 결과를 얻었다. 1. 치아이동 후 압박측에서는 치주인대 공간의 압축과 함께 치주인대섬유가 굵어진 소견을 보였으며 인장측의 치주인대섬유는 신장되어 보였다. 2. 보정 4주 후 유연성 고정군에서는 치주인대섬유의 재배열이 관찰되었으나 견고성 고정군에서는 관찰되지 않았다. 3. 보정 8주 후부터는 두 군 모두에서 치주인대섬유의 재배열 소견이 관찰되었으며, 두 군간 치주인대섬유의 재배열 차이는 보이지 않았다. 4. 보정기간 동안 치주인대섬유의 재배열은 압박측 보다 인장측에서 빠른 소견을 보였다. 이상의 결과는 치아이동 후 견고하게 고정한 보정방법에서도 치주인대섬유의 재배열이 일어남을 보여주었고, 치아 보정시 폴리에틸렌 리본으로 고정한 보정장치도 유용하게 사용될 수 있음을 시사하였다.

Keywords