• Title/Summary/Keyword: 청주

Search Result 1,666, Processing Time 0.024 seconds

Assesment of Impaired Depth due to Fire of Mock-up Concrete with 21MPa Using Drying Method After Water Immersion (수중 침지 건조방법을 이용한 21MPa급 Mock-up부재 콘크리트의 화해피해 깊이진단)

  • Lim, Gun Su;Han, Jun Hui;Hyun, Seung Yong;kim, Jong;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.241-242
    • /
    • 2021
  • In this study, we develop the damage depth diagnostic technology of fire damage concrete and propose an method of impaired depth due to fire by drying impaired concrete after immersing. Test results indicated that when assesing impared depth due to fire with the dry method after water immersing, impaired depth was clearly found and furthermore, compared with that by Phenolphthalein method 10 mm of damage depth was additionally identified, which is imposible to asses when Phenolphthalein is applied.

  • PDF

A Study on the Estimation of Setting Time for High Strength Concrete Using Durometer (개량형 Durometer를 이용한 고강도 콘크리트의 응결시간 추정 가능성 분석)

  • Sin, Se-Jun;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.87-88
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

The Bond Strength of Super Retarding Concrete According to Delay Time of Placement (타설지연시간 변화에 따른 초지연제 사용 콘크리트의 부착강도)

  • Han, Soo-Hwan;Sin, Se-Jun;Choi, Yoon-Ho;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.75-76
    • /
    • 2020
  • In this study, in order to check whether the adhesion strength can be secured when installing concrete by mixing super-retarding agents, the splitting tensile strength of the joints of each mold was measured and then analyzed. The results of the experiment showed that the bonding performance of the joint is adversely affected if the installation delay is delayed for more than 24 hours, and that the attachment performance can be secured if the installation is delayed within about 24 hours.

  • PDF

Asessment of Fire Damage Depth of 21MPa-class Concrete Using Thermogravimetric Analysis (열중량분석을 활용한 21MPa급 콘크리트의 화해피해깊이 진단방법 분석)

  • Lim, Gun Su;Han, Soo Hwan;Han, Jun Hui;Yoon, Chee Whan;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.243-244
    • /
    • 2021
  • In this study, we develop diagnostic technology for damage depth of fire-damaged concrete and propose methods for damage caused by fire by drying damaged concrete after immersion. As a result of the test, the damaged depth was clearly found when evaluating the depth of impurities caused by fire in a drying method after water had permeated, and it could be verified using thermogravimetric analysis.

  • PDF

Assesment of Impaired Depth due to Fire of Mock-up Concrete with 40MPa Using Drying Method After Water Immersion (수중 침지 건조방법을 이용한 40MPa Mock-up부재의 화해피해 깊이진단)

  • Lim, Gun Su;Han, Soo Hwan;Baek, Seung Bok;Kim, Jong;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.245-246
    • /
    • 2021
  • In this study, we develop the damage depth diagnostic technology of fire damage concrete and propose an method of impaired depth due to fire by drying impaired concrete after immersing. Test results indicated that when assesing impared depth due to fire with the dry method after water immersing, impaired depth was clearly found and furthermore, compared with that by Phenolphthalein method 15 mm of damage depth was additionally identified, which is imposible to asses when Phenolphthalein is applied.

  • PDF

Hydration Heat Analysis of Mass Concrete Replacement of Low Heat Binder and CGS with Fine Aggregate (저발열 결합재 및 CGS를 잔골재로 치환한 매스콘크리트의 수화열 해석)

  • Han, Jun-Hui;Lim, Gun-Su;Chi, Il-Kyeung;Yoon, Chee-Whan;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.235-236
    • /
    • 2021
  • This study evaluated temperature distribution through adiabatic temperature rising test and hydration heat Analysis as a performance verification to utilize CGS as a hydration heat reduction material for mass concrete when replacing it with fine aggregate. According to the analysis, the temperature difference between the center and the surface was the highest at about 30℃, followed by the CGS 50% at 26℃ and the low heat combiner FA 30% at 23℃.

  • PDF

Properties of Adiabatic Temperature Rising of Concrete Using Coal Gasification Slag as Fine Aggregate (석탄 가스화 용융 슬래그를 잔골재로 사용한 콘크리트 단열온도상승 특성)

  • Han, Jun-Hui;Lim, Gun-Su;Chi, Il-Kyeung;Kim, Jung;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.114-115
    • /
    • 2021
  • The research team conducted a series of studies to use CGS as fine aggregate for concrete. In this paper, through the adiabatic temperature rising test, CGS' hydration heating performance and its usability as a mass concrete hydration heating agent were reviewed. According to the analysis, the maximum temperature of the mix of OPC 100 was 53.7℃, and the temperature of CGS 50% was 45.2℃, which was 8.5℃ lower than the OPC 100.

  • PDF

Prediction of Setting Time of Ternary Blended Mortar According to Super-Rretarding Aagents Dosages Applying Maturity Method (적산온도 방법에 의한 초지연제 혼입율에 따른 3성분계 모르타르의 응결시간 예측)

  • Han, Soo-Hwan;Jeong, Yeong-Jin;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.233-234
    • /
    • 2021
  • This study proposed a condensation prediction method for mortar mixed with super retardant using the additive temperature method. As a result, it is believed that the condensation prediction using the additive temperature method is highly plausible.

  • PDF

A Study on the Strength Recovery Performance Evaluation of Concrete replaced by CBS-Dust and FA (CBS-Dust와 FA를 치환한 콘크리트의 강도회복성능 평가)

  • Han, Soo-Hwan;Han, Jun-Hui;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.231-232
    • /
    • 2021
  • This study intended to verify the alkali activation effect of concrete by replacing FA and CBS-Dust with cement to find out how to utilize CBS-Dust generated during cement production. Experiments result shows that air flow and liquidity can be secured when CBS-Dust is replaced by 5% in FA 20%, and that relatively high compressive strength is expressed in the initial age of 3 days and 7 days and long-term age of 91 days.

  • PDF

Measurement of Cement Content on Concrete Using the Method of Hydrochloric Acid Melting Heat (염산용해열법을 이용한 콘크리트의 단위시멘트량 추정)

  • Kim, Sang-Min;Sin, Se-Jun;Hyun, Seung Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.102-103
    • /
    • 2020
  • In this study, the effect of the change in the cement contents on the basic properties of the concrete and the estimation of the cement contents of hardened concretes using the hydrochloric acid melting heat. As a result of the study, as the cement contents increased, the fluidity and compressive strength increased, and there was no significant difference in the air contents and the unit volume mass. In addition, it showed a high correlation when compared with the estimated cement contents derived using the hydrochloric acid melting and the cement contents at the time of mixing. Therefore, it is considered that the hydrochloric acid melting is possible as a method of estimating the cement contents of concrete.

  • PDF