• Title/Summary/Keyword: 직각도 측정

Search Result 143, Processing Time 0.027 seconds

Lateral Compression and Dowel Bearing Property of Japanese Larch Grown in Korea (국산 낙엽송재의 횡압축과 다우얼 지압 성능)

  • Hwang, Kweonhwan;Park, Byung-Su
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.61-69
    • /
    • 2008
  • To examine the compression properties of structural members, the compression and bearing tests were conducted in parallel- and perpendicular-to-grain loading using domestic Japanese larch (Larix kaempferi (Lamb.) Carriere). Compression (bearing) properties with the length of a specimen and the contact length of the bearing plate were investigated, and deformations at each specimen length from the point of bearing force were measured to evaluate the effective end distance tabulated in the present practice (Korean Building Code). Compression (bearing) properties varied with the size of the bearing plate, and the end distance for dowel-type fastener taken into consideration of the specimen's deformation, for the safe design, should be applied with over 7 D.

A Study on Mechanical Properties of Strand/Particle Composites (II) - Measuring of Young's Moduli and Estimating of Anisotropy Using an Ultrasonic Method - (스트랜드/파티클 복합체의 기계적 성질에 관한 연구(II) - 탄성률 측정 및 초음파법에 의한 이방성의 예측 -)

  • Kim, Yu-Jung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2001
  • Composites with various layer constructions involving the ratio of S/P were produced from wood strands(S) and particles(P) (Cryptomeria japonica D.Don) to measure various Young's moduli and anisotropy by ultrasonics. As a result, static Young's moduli of composites were almost same as dynamic Young's moduli obtained from natural frequency. However, these were smaller than those evaluated from ultrasonic wave propagation velocity. The differences between propagation velocity of the parallel(${\parallel}$) and perpendicular(${\bot}$) in-plane direction resulted in a tendency of anisotropy. The tendency of anisotropy was larger in three-layer constructions than in seven-layer constructions. The differences of strand surface layers showed larger values than those of particle surface layers. Also, composites with higher weight ratio of strand had a tendency to propagate rapidly in each direction. In contrast to these results, the propagation velocity in the thickness direction had a tendency to propagate rapidly in composites with particle surface layers and the lower weight ratio of strand.

  • PDF

The Development of Motivation Scale in the Visual Artistic Giftedness of the Elementary School Children (학동기 미술영재성 동기요인 검사도구 개발)

  • 이용애
    • Journal of Gifted/Talented Education
    • /
    • v.13 no.2
    • /
    • pp.23-41
    • /
    • 2003
  • The purpose of this study was to develop the instruments which can measure motivation as a component of Visual Artistic Giftedness with in elementary school period. This study prescribed the variable factors of measurement after abstract and classify the characteristics of Visual Artistic Giftedness through literature studies. And it produced instruments those are finally composed of 27 items through the preliminary test. They were evaluated in terms of content validity, construct validity, and reliability by implementing them to 679 elementary school children from the first to sixth grades. Statistical analyses were carried out to verify the validities and reliability. Content validity was found to be satisfactory by experts' evaluation on the test items. Construct validity was also found to be satisfactory through factor analyses which showed the four factors which the identification instruments were intended to measure such as, interest/ attitude/ taste, endurance/ concentration, curiosity/ imagination! sensitiveness, aesthetic. Concurrent validity was also found to be satisfactory with high coeffients of Barron- Welsh which were calculated as .76 in motivation. In conclusion, the instruments about motivation of Visual Artistic Giftedness during elementary school period developed by this study are highly reliable on its reliability and validity.

The Development of behavior Characteristics Scale in the Mathematically Giftedness of the Middle School (수학 영재를 위한 행동 특성 검사도구 개발)

  • Hwang, Dong-Jou
    • Journal of the Korean School Mathematics Society
    • /
    • v.9 no.3
    • /
    • pp.405-424
    • /
    • 2006
  • The purpose of this study was to develop the instruments which can measure behavior characteristics as a component of Mathematically Giftedness with in middle school period. This study prescribed the variable factors of measurement after classify the characteristics of Mathematically Giftedness through literature studies. And it produced instruments those are finally composed of 51 items through the preliminary test. The participants for the study were 424 Korean middle school students. Statistical analyses were carried out to verify the validities and reliability. Reliability(Cronbach $\alpha$) was in behavior characteristics, .95. Content validity was found to be satisfactory by internal validity evaluation on the test items. Internal validity were analyzed by BIGSTEPTS based on Rasch's 1-parameter item-response model. Construct validity was also found to be satisfactory through factor analysis which showed the four factors which the identification instruments were intended to measure such as, General mathematical mental ability, Mathematical Ability, Processing and Obtaining mathematical information Anility and Mathematical Disposition Ability. In conclusion, the instruments about behavior characteristics of Mathematically Giftedness during middle school period developed by this study are highly reliable on its reliability and validity.

  • PDF

Display-Pixel-Based Focusing Method for Ultrasound Imaging (의료 초음파 영상을 위한 화소단위 집속기법)

  • 황재섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.419-431
    • /
    • 2000
  • In this paper, a new beamforming technique is proposed, which can completely eliminate all the artifacts caused by digital scan converter. In the proposed method, named display-pixel-based focusing(DPBF) by the authors, ultrasound waves are focused directly at the display pixels instead of sampling points on the polar coordinate. Consequently. the DPBF system does not require the digital scan converter. To verify the proposed method, we modified a commercial scanner and performed experiments with a 3.5 MHz convex array and a 7.5 MHz linear array. We also defined and measured ICRA/B(Image Coarseness Ratio) to compare the image quality quantitatively. The experimental results with in vivo and in vitro data show that the proposed method improves the ICRA/B considerably, resulting in much smoother and finer images.

  • PDF

Detection of the Defect on the Metal Surface Using the Modulated Microwave (변조 고주파에 의한 금속표면 결함 검출)

  • Joo, G.T.;Jung, S.H.;Song, K.Y.;Kim, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.173-179
    • /
    • 1999
  • The defects on the metal surface. such as the ended circular pressed hole. the penetrated circular drilled hole, and the linear hollow lanes have been investigated by means of the microwave. In this experiment, frequency was set at 9.2GHz with 3kHz modulation, and the methods of reflection, transmission, fixed carrier frequency, and mod-demodulated technique have been used for investigating defects. The magnitudes of the microwave signals have been changed at the ended circular pressed hole and the penetrated circular drilled hole. The defect sizes that were estimated from the reflected microwave signals had the dimensions enlarged by twice the original size of the penetrated circular drilled hole and 2.5 times the original size of the ended circular pressed hole. The magnitudes of the reflected microwave signals from the linear hollow lane have increased with expansion of the width of the notch. In the linear hollow lane with the depth of 2.4mm, the reflected microwave signals versus the defect widths had a maximum value at the defect width of 50mm, and in the linear hollow lanes with the depths of 1.2mm and 0.45mm, the reflected microwave signals versus the defects widths had the maximum values each at the defect depths of 55mm.

  • PDF

Project of Dam Safety reinforcement on Gampo Dam (감포댐 안전성강화 사업)

  • Cheon, Geun Ho;Han, Yong Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.214-214
    • /
    • 2022
  • 감포댐은 2006년 준공하여 각종 시설 및 설비의 노후화가 진행중에 있으며, 최근 감포댐 인근 지역에서 발생한 경주지진(규모 5.8) 및 포항지진(규모 5.4)이 발생하여 지진시 시설물의 안전성에 대해 중요성이 대두되고 있었다. 이에 감포댐 안전성강화 사업을 추진하게 되었고, 주요 사업내용은 취수탑 관리교 내진보강, 댐체 심벽보강을 통한 댐체 안전성확보, 비상방류시설 개선이다. 취수탑 관리교는 교각단면의 변위연성도 및 교량받침에 의한 구조물 안전성 평가를 시행하였고, 단면강도는 모멘트-곡률해석법에서 탄성영역의 단면강도 대비 탄성지진력을 비교하여 안전성을 검토하였다. 검토결과 교량받침의 내진성능은 부족한 것으로 검토되어 유량제어형 멀티펌프와 안전잭을 이용한 변위제어 방식의 교량동시 인상공법이 가능하고 인상정밀도 ±0.5mm이내의 성능을 가진 교량인상공법 적용하여 보강을 하는 것으로 계획하였다. 댐체 심벽보강을 위해 먼저 전기비저항탐사를 수행하여 전기비저항대를 탐사하여 심벽부에서 포화대가 형성된 부위를 조사하였다. 그리고 댐 상·하류에 전극을 설치하고 전류를 발생시켜 측정 지점별 자기장을 측정을 통하여 댐체내 침투에 따른 유로 형성여부 파악을 위한 전자기장탐사를 시행하였다. 마지막으로 심벽 시추조사를 시행하여 공내수를 조사하였다. 조사결과 포화대의 위치 및 이상대가 다양한 것으로 나타났으며, 이는 불특정 지점에 연약대가 존재한다 판단하여 심벽부 보강계획을 전반적으로 적용하는 것으로 결정하였다. 비상방류시설은 최근 15년 실측자료의 홍수기(6~9월) 평균유입량을 적용하여 검토하였으며 검토결과 배제대상 높이 75%까지는 3.7일, 완전배제까지는 11.2일이 걸려 댐설계기준을 충족하는 것으로 검토되다. 다만 감포댐 비상방류시설이 하천제방과 직각방향으로 형성되어 있고, 하천의 폭이 좁아 과거 방류시에도 제방을 월류하는 것으로 조사되어 하천의 세굴을 방지하고 제방 안전성을 확보하기 위하여 비상방류시설에 감세공을 설치하고, 제방에 디플렉터 옹벽을 설치하는 것으로 계획하였다. 감세공은 2번에 걸친 감세효과로 방류시 하류바닥 및 옹벽 보호 효과가 큰 미국 USBR의 TypeVI를 적용하였으며, Flow-3D 모델링을 통하여 제방에 월류가 발생하지 않는 최적의 대안 옹벽규모를 산정하였다.

  • PDF

Vehicle Acceleration and Vehicle Spacing Calculation Method Used YOLO (YOLO기법을 사용한 차량가속도 및 차두거리 산출방법)

  • Jeong-won Gil;Jae-seong Hwang;Jae-Kyung Kwon;Choul-ki Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.1
    • /
    • pp.82-96
    • /
    • 2024
  • While analyzing traffic flow, speed, traffic volume, and density are important macroscopic indicators, and acceleration and spacing are the important microscopic indicators. The speed and traffic volume can be collected with the currently installed traffic information collection devices. However, acceleration and spacing data are necessary for safety and autonomous driving but cannot be collected using the current traffic information collection devices. 'You Look Only Once'(YOLO), an object recognition technique, has excellent accuracy and real-time performance and is used in various fields, including the transportation field. In this study, to measure acceleration and spacing using YOLO, we developed a model that measures acceleration and spacing through changes in vehicle speed at each interval and the differences in the travel time between vehicles by setting the measurement intervals closely. It was confirmed that the range of acceleration and spacing is different depending on the traffic characteristics of each point, and a comparative analysis was performed according to the reference distance and screen angle to secure the measurement rate. The measurement interval was 20m, and the closer the angle was to a right angle, the higher the measurement rate. These results will contribute to the analysis of safety by intersection and the domestic vehicle behavior model.

Soil Quality Assessment for Environmentally Sound Agriculture in the Mountainous Soils; Analysis of Sediment Data and Suggestion of Best Management Practices (산지에서의 환경보전형 농업을 위한 토양의 질 평가;유사자료의 분석과 최적영농방법의 제안)

  • Choi, Joong-Dae;Park, Ji-Sung;Kim, Jeong-Je;Yang, Jae-E;Jung, Yeong-Sang;Yun, Sei-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.3
    • /
    • pp.201-205
    • /
    • 2000
  • Eleven runoff $plots(3{\times}15\;m)$ were built on a sloping field of a high plateau in Kangwon Province, Korea. The plots were treated with different tillage, residue covers and fertilizers, corn and potato were cultivated, and sediment discharge was measured from the plots for 3 years. Agricultural management practices were monitored around the plots to develop adequate best management practices. The least sediment occurred from the plots with no-till and 100% residue cover $(corn,\;0.1{\sim}2.2\;t/ha/year)$ and with contour tillage and vinyl sheet cover plots $(potato,\;0.1{\sim}0.2\;t/ha/year)$. The largest sediment was measured from the plots with up-and-down till and no cover ($11{\sim}33$ and $16{\sim}31\;t/ha/year$ from corn and potato plots, respectively). The type of organic and commercial fertilizers seemed not to affect sediment discharge. Sediment discharge from contour plots were largely dependent on the collapse of ridges due to the flush of water stored in furrows. The sediment discharge from contour corn and potato plots with no residue cover was $10{\sim}27$ and $16{\sim}24\;t/ha/year$, respectively. No-till with residue cover, vinyl cover for tuber crops, construction of furrow dam, frost heave research, furrow and ridge tillage with furrow dam after tuber crop harvest, limited stalk harvest of row crops, use of winter cover crops, and other common best management practices were recommended to minimize the sediment discharge from a high plateau sloping land culture.

  • PDF

Gravimetric and magnetic studies in an Yangsan fault area near Angang (안강부근 양산단층 지역에서의 중력 및 지자기 연구)

  • Kim, Gi Yeong;Lee, Gwang Ja
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1998
  • Gravimetric and magnetic surveys were conducted in order to reveal near-surface structures such as basements, faults, and fracture zones in an area near Angang, where the Yangsan fault is believed to pass through. Along two lines approximately perpendicular to the strike of the major fault, gravity and magnetic data were measured at 67 stations with a 15 m interval and at 296 stations with a 3 m interval, respectively. Average depth to the magnetic basement is estimated using the spectral analysis method to be 8.5 and 10.0 m along lines located to the east and the west of the Hyeongsan river, respectively. Average value of reduced gravity on the east line is higher than that on the west by the amount of 1.71 mGal, which indicates that the basement rocks are more severely fractured in the western part. Forward gravity modeling along the east line indicates that a fracture zone extends westward from a fault located 210 m west of the eastern end. Density and depth to the bottom of the fracture zone are estimated to be 2.44 g/cm3 and 70 m, respectively. The gravity model study also indicates presence of a small graben, 190 m wide and 3.5 m deep on an average, on the basement surface. The earth surface above the graben is approximately 44 cm lower than the nearby surface. This indicates that the graben might have been formed by recent fault movements.

  • PDF