• Title/Summary/Keyword: 지점 검출

Search Result 468, Processing Time 0.027 seconds

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

Assessment of Distribution Patterns and Sources for PAHs, OCPs, and Co-PCBs in the Surface Sediments from the Nakdong River Basin, Korea (낙동강 하천 및 호소 퇴적물에서의 PAHs, OCPs, Co-PCBs 농도 분포와 발생원 평가)

  • Kang, Hee-Hyung;Lee, In-Seok;Huh, In-Ae;Shin, Won-Sik;Hwang, In-Sung;Kim, Young-Hoon;Hur, Jin;Shin, Hyun-Sang;Kim, Joon-Ha;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.7
    • /
    • pp.656-664
    • /
    • 2010
  • We investigated the levels and distribution patterns of 16 priority polycyclic aromatic hydrocarbons (PAHs), 12 Coplanar polychlorinated biphenyls (Co-PCBs) and organochlorine pesticides (OCPs) in the surface sediments from the Nakdong river basin, Korea. The levels of 16 PAHs and 12 Co-PCBs in the river sediment samples ranged from not detected (N.D.)~969.3 ng/g-dry, 4.2~7716.5 pg/g-dry (0.0~10.1 pg-TEQ/g-dry), respectively. Also, the levels of 16 PAHs were from 5.8~2987.2 ng/g-dry and 4.3~461.1 pg/g-dry (0.0~0.6 pg-TEQ/g-dry) for 12 Co-PCBs in the lake sediment samples. Only dichloro-diphenyl-trichloroethane (DDT) were detected among target OCPs and the concentration ranged from N.D.~1.5 ng/g-dry in the river sediment samples. These contamination levels were far below the guideline values suggested for environmental quality assessment. Low molecular weight PAHs were dominant in the river sediment samples, while middle and high molecular weight PAHs were dominant among 16 PAHs in the lake sediment samples. PCB-118 and PCB-105 were predominant congeners in the sediment, which were similar to the results obtained from previous studies. With these results, the assessment of potential sources of PAHs and Co-PCBs contamination in the sediments of the Nakdong river basin was performed. The pyrogenic-PAHs originated from combustion of fossil fuel and biomass were related with the PAHs contribution in most of the sediment samples, and Co-PCBs in the sediment samples were related with commercial PCB products.

Microbiological Hazard Analysis and Verification of Critical Control Point (CCP) in a Fresh-Cut Produce Processing Plant -Case Study of a Fresh-Cut Leaf Processing Plant- (신선편이 농산물 가공업체의 미생물학적 위해 요소 분석 및 중점 관리 지점(CCP)의 검증 -신선편이 엽채류 가공업체를 대상으로-)

  • Kim, Su-Jin;Sun, Shih-Hui;Min, Kyung-Jin;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.3
    • /
    • pp.392-400
    • /
    • 2011
  • The objectives of this study were to analyze environmental microbial contamination levels by sampling the surfaces of processing lines and equipment and to verify CCPs of the HACCP plan in a fresh-cut produce processing plant The level of airborne microorganisms in the processing plant was $10^1$ log CFU/plate/15min. Total plate counts and coliform groups of the processing facilities were 1~2 log CFU/100 $cm^2$. No E. coli or S. aureus were detected in the processing plant. However, total plate counts on the cutting board for raw materials and on the spin-dryer were $4.20{\pm}2.12$ log CFU/$cm^2$ and $4.57{\pm}0.92$ log CFU/$cm^2$, respectively. These levels were higher than the safe microbial level, and therefore, the chance of cross-contamination during processing was increased. According to the results of microbiological analyses, total aerobic bacteria and coliform groups of the samples were increased after the second washing and spin-drying steps, due to cross-contamination from the spin-dryer. Thus, an effective method that can be used for microbial control during the washing and drying steps is needed for microbial control in fresh-cut produce processing plants. The results of a verification study also suggest that modification of the HACCP plan is needed along with additional CPs, which were identified as a second washing, spin drying, and the cold storage of final products.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Water Quality of Some Spring Waters in Pusan Area (부산시내에 산재하는 몇몇 약수터 약수의 수질)

  • KIM Yong-Gwan;CHO Hyeon-Seo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.538-544
    • /
    • 1985
  • This study was carried cut to evaluate the water quality of spring waters in Pusan area(see Fig. 1). In this experiment, twenty-five water samples were collected from 5 stations from December 1983 to August 1984. Range and mean values of constituents of the samples are as follows: pH $5.80{\sim}7.25$, 6.60; water temperature $6.0{\sim}23.0^{\circ}C,\;12.9^{\circ}C$; total residue $33.0{\sim}325mg/l$, 121.2mg/l; alkalinity $4.75{\sim}51.6mg/l$, 24.1mg/l; hardness $9.47{\sim}85.0mg/l$, 30.3mg/l; electrical conductivity $0.495{\sim}2.750{\times}^2{mu}{\mho}/cm,\;1.239{\times}10^2{\mu}{\mho}/cm$;turbidity $0.54{\sim}7.80$NTU, 2.04NTU; $KMnO_4$ consumed $0.51{\sim}8.47mg/l$, 1.96mg/l; chloride ion $4.91{\sim}36.0mg/l$, 12.55mg/l; fluoride ion ND-0.30ppm, 0.08ppm; nitrate-nitrogen ND-8.94mg/l, 1.94m:g/l; nitrite-nirogen ND-0.10mg/l, 0.03mg/l; ammonia-nitrogen ND-0.16mg/l, 0.03mg/l: phosphate-phosphorus ND-0.09mg/l, 0.03mg/l; silicate-silicious $0.42{\sim}22.7ng/l$, 7.96mg/l; copper ND-10.5ppb, 2.46ppb; lead ND-22.7ppb, 3.54ppb; zinc ND-103ppb, 21.33ppb; iron $20.3{\sim}2,800ppb$, 801.72ppb, respectively. Arsenic, cyan, cadmium, manganese, mercury, chrome and phenol were not detected. Total residue, electrical conductivity, turbidity and chloride ion of station 1 (Milrakdong) were higher than others as 178.1mg/l, $2.127{\times}10^2{\mu}{\mho}/cm$, 3.16NTU and 16.32mg/l. The concentration of silicious had a great influence on precipitation. The concentration of fluoride ion of spring waters was lower as 0.08ppm than the criterion for drinking water as 1ppm, while iron was exceed 2.7 times as 801.72ppb.

  • PDF

Investigation of Soil Contamination of Some Major Roadsides in Seoul -II. Major Roadsides in Gangdong-, Gwangjin-, Nowon-, Seodaemun- and Seongdong-gu- (서울시 주요 도로변 토양오염 조사 -II.강동구, 광진구, 노원구, 서대문구, 성동구 내 주요 도로변 토양-)

  • Kim, Kwon-Rae;Lee, Hyun-Haeng;Jung, Chang-Wook;Kang, Ji-Young;Park, Soon-Nam;Kim, Kye-Hoon
    • Applied Biological Chemistry
    • /
    • v.45 no.2
    • /
    • pp.92-96
    • /
    • 2002
  • Present contamination levels of soils along the major roadsides of Seoul, Korea were investigated, and base-line data were accumulated for future use. Topsoil $(1{\sim}5$ cm) and subsoil $(20{\sim}50$ cm) from five districts (Gangdong-, Gwangjin-, Nowon-, Seodaemun- and Seongdong-gu) were sampled. The collected samples were airdried, passed through 2-mm sieves, and analyzed to determine the physicochemical properties including pH, EC, CEC, exchangeable cations (Ca, Mg, K, and Na), and heavy metal contents (Cd, Cu, Pb, and Zn). Soil textures of topsoils and subsoils were mainly loamy sand and sandy loam, respectively. The range of pH was $4.5{\sim}10$.0 with an average of 7.5 for both topsoil and subsoil, which is much higher than that of the forest soils in Seoul. The ranges of 0.1 N HCI extractable Cd, Cu, Pb, and Zn contents for both topsoils and subsoils were $0.0l{\sim}l.19$, N.D. (not $detected){\sim}228$.99, $N.D.{\sim}352$.54, and $2.97{\sim}332$.96 mg $kg^{-1}$, respectively. Most of the average heavy metal contents were lower than the concern level of the Soil Environment Conservation Act of Korea, but were much higher than those of the , forest soils in Seoul. Some sites were higher in heavy metal contents than the concern levels; in particular, the average Cu content in Seongdong-gu was much higher than the concern level, 50 mg $kg^{-1}$. Careful management of the soil to prevent the aggravation of the present contamination level and the dissemination of contamination is highly recommended.

Concentration Levels and Distribution Characteristics of Polycyclic Aromatic Hydrocarbons (PAHs) at Ambient Air in Industrial Complex Area (공단지역 대기 중 다환방향족탄화수소화합물(PAHs)의 농도수준 및 분포특성)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Cho, Sang-Won;Ok, Gon;Shon, Byung-Hyun;Lee, Kwan;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.379-388
    • /
    • 2011
  • The purpose of this study was to investigate the concentration levels, distribution characteristics and blood concentration of Polycyclic Aromatic Hydrocarbons (PAHs) at ambient air in Industrial Complex Area. The samples were collected at 4 sites in Industrial Complex Area and its vicinities. The result indicated that there was the difference of PAHs concentration as followed local characteristics. The level of average concentration of PAHs in the air in Industrial Complex Area was $14.52{\sim}193.48ng/m^3$. The level of average concentration of six materials with possibility of cancer creation was $1.65{\sim}13.44ng/m^3$. The concentrations of PAHs were generally low, but Jechul-dong is considered an area where consistent monitoring of PAHs is required. In addition, benzo(a)pyrene was detected in every atmospheric sample, however the concentration was not high. The level of concentration of benzo(a)pyrene in the air in the Jechul-dong was $2.89ng/m^3$. But, the concentration of the PAHs in Jechul-dong showed that the Benzo(a)pyrene concentration is above $1ng/m^3$ of air quality standard(EU). The results of the concentration level of PAHs in the blood from 240 persons who were exposed directly were surveyed, it was $1.12{\sim}11.45ng/m^3$ for man and $1.20{\sim}26.89ng/m^3$ for woman. It was indicated that the difference between the genders was very little. The accumulation inside human was anticipated as the PAHs concentration in the blood for the aged was very high. Industrial Complex Area and its vicinities are an area which has been greatly influenced by PAHs and environmental contaminants. It is necessary to control the emission sources of PAHs and to construct an observation system at Industrial Complex Area from now on. It is time to reduce the risk factors for health and environmental disease to protect the health of resident in Industrial Complex Area and its vicinities.

Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area (공단지역 토양 중 환경오염물질 농도 분포 특성)

  • Jung, Jong-Hyeon;Cho, Sang-Won;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.200-208
    • /
    • 2012
  • This study was performed to prevent the health damage of environmental contaminants in Industrial Complex Area. And, this study aimed to identify the concentration levels and distribution characteristics of environmental contaminants and Polycyclic Aromatic Hydrocarbons (PAHs) at soil in Industrial Complex Area and control area. The concentration of the soil pollution standard such as the heavy metals in the soil, VOCs, PAHs, and PCB were measured and analyzed using the soil specimens in the Industrial Complex Area and control area. Soil specimens from the Industrial Complex Area (the direct exposure area) and the control area were surveyed. Songdo-dong, Haedo-dong and Jechul-dong, which are in the direct exposure area and near the emission source, showed relatively high concentrations of contaminant materials when compared with Jangki-myeon, which is far off and in the control area. The concentration of zinc was 20.8-58.9% of the level of concern (300 mg/kg) in the 1st region, which is a relatively high concentration. The concentration of fluoride was under the standard in every region, but it was about 74% of the level of concern (400 mg/kg) in the 1st region. It is recommended that controlling fluoride emissions is necessary. Levels of organic phosphate, phenol, and VOCs like benzene, toluene, ethylbenzene and xylene were under the detection limit of the analysis instruments. The concentration of TPH was high in Songdo-dong. The concentration of contaminants in Jechul-dong was high. In addition, it was observed that the level of soil contamination changed depending on the distance from the emission source. The concentration of PAH compounds in the soil was 18.71-1744.59 ng/g, and the concentration of six potential cancer-causing PAH materials was 6.54-695.94 ng/g. The highest concentration was in Songdo-dong. The PAH concentration in the direct exposure area near the complex was relatively high compared to the indirect exposure area.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

Monitoring of Pesticide Residues Concerned in Stream Water (전국 하천수 중 잔류우려 농약 실태조사)

  • Hwang, In-Seong;Oh, Yee-Jin;Kwon, Hye-Young;Ro, Jin-Ho;Kim, Dan-Bi;Moon, Byeong-Chul;Oh, Min-Seok;Noh, Hyun-Ho;Park, Sang-Won;Choi, Geun-Hyoung;Ryu, Song-Hee;Kim, Byung-Seok;Oh, Kyeong-Seok;Lim, Chi-Hwan;Lee, Hyo-Sub
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.3
    • /
    • pp.173-184
    • /
    • 2019
  • BACKGROUND: This study was carried out to investigate pesticide residues from fifty streams in Korea. Water samples were collected at two times. Thee first sampling was performed from april to may, which was the season for start of pesticide application and the second sampling event was from august to september, which was a period for spraying pesticides multiple times. METHODS AND RESULTS: The 136 pesticide residues were analyzed by LC-MS/MS and GC/ECD. As a result, eleven of the pesticide residues were detected at the first sampling. Twenty eight of the pesticide residues were detected at the second sampling. Seven pesticides were frequently detected from more than 10 water samples. Ecological risk assessment (ERA) was carried out by using residual and toxicological data. Four scenarios were applied for the ERA. Scenario 1 and 2 were performed using LC50 values and mean and maximum concentrations. Scenarios 3 and 4 were conducted by NOEC values and mean and maximum concentrations. CONCLUSION: Frequently detected pesticide residues tended to coincide with the period of preventing pathogen and pest at paddy rice. As a result of ERA, five pesticides (butachlor, carbendazim, carbofuran, chlorantranilprole, and oxadiazon) were assessed to be risks at scenario 4. However, only oxadiazon was assessed to be a risk at scenario 3 for the first sampling. Oxadiazon was not assessed to be a risk at the second sampling. It seems to be temporary phenomenon at the first sampling, because usage of herbicides such as oxadiazon increased from April to march for preventing weeds at paddy fields. However, this study suggested that five pesticides which were assessed to be risks need to be monitored continuously for the residues.