• Title/Summary/Keyword: 지붕 표면온도

Search Result 19, Processing Time 0.032 seconds

Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface (온도 변색 도료의 지붕 적용 및 냉방효과 분석)

  • Baek, Sanghoon
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.115-123
    • /
    • 2022
  • This study aims to introduce a temperature discoloration roof system and its cooling effect in the summer. Temperature discoloration paints can reverse their colors based on temperature changes. If these paints on the roof surface could color-shift between white in the summer and black in the winter, the indoor cooling and heating loads can be affected by the changes in reflection and absorption of solar radiation. Focusing on the summer period, the study analyzed the cooling effect of applying temperature discoloration paint that color-shifts from white to black on the roof surface of a small experimental building module and compared it to commonly used gray and green roof colors. Results of the experiment showed that the surface temperature of the roof with temperature discoloration paint was lower than the gray and green color roofs by a maximum of 10℃. Furthermore, the indoor temperature of the experimental module with the temperature discoloration roof was lower than the gray and green roofs by approximately 3℃. Findings of the study indicate that the application of temperature discoloration paint to the roof can reduce indoor cooling loads.

An Experimental Study of Green Roofs on Indoor Temperature Reduction (옥상녹화의 건물 내 온도 저감 효과에 대한 실험적 연구)

  • Kang, Da Won;Choi, Hui Dong;Seo, Yong Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.157-157
    • /
    • 2021
  • 2015년 파리에서 체결된 파리협정은 1850년 대비 2100년까지의 지구 평균기온 상승을 1.5℃ 이내로 제한하기 위해 5년마다 참여국에 상향된 온실가스 배출 감축 목표를 제출하게 하고, 탄소 배출 및 온도상승 저감 목표 달성을 위해 도시 내 그린인프라를 적극적으로 도입하는 등 국제사회 공동의 종합적인 이행을 예정하고 있다. 그린인프라의 유형 중 하나인 옥상녹화(Green Roof)는 기후변화 적응을 위한 도시 인프라 구축 방법의 하나로 국내에서도 많은 각광을 받고 있다. 옥상녹화(Green Roof)는 도시의 불투수층인 지붕 면적을 모두 혹은 일부 식생으로 덮어 표면층에 추가의 투수층을 조성하는 것을 지칭한다. 옥상녹화의 경우 별도의 토지면적 확보가 필요하지 않고 기존의 시설물에 추가적인 설치가 가능해 여분의 토지가 부족한 도심지의 녹지 확보를 위한 친환경적인 그린인프라로 각광받고 있다. 현재까지 옥상녹화(Green Roof) 관련 국내 연구 현황은 '옥상 녹화의 공법'을 다룬 비율이 높고 실증적인 결과를 가진 선행연구가 거의 없다. 따라서 본 연구는 동일한 조건하에 4개의 실험동을 설치하고 동질성 검사를 한 후 옥상에 설치된 재료[일반 콘크리트(Bare Concrete), 고반사 도장(High Reflective Paint), 사사(Short Bamboo), 잔디(Grass)]에 따른 건물 내 온도 변화 저감효과에 대한 분석을 수행하였다. 2020년 8월 17일부터 22일까지 측정된 지붕 표면 평균 최고온도 모니터링 결과를 일반 콘크리트 지붕과 비교했을 때. 고반사 도장 지붕의 경우 8.26℃, 옥상녹화(사사, short bamboo) 지붕의 경우 7.21℃, 옥상녹화(잔디, grass)의 경우 10.8℃ 낮은 것으로 측정되었다. 또한 실내 천정 표면 평균 온도의 경우 콘크리트 지붕과 비교하여 고반사 도장 지붕은 6.46℃, 옥상녹화(사사, short bamboo) 지붕은 13.52℃, 옥상녹화(잔디, grass)는 13.3℃ 낮은 것으로 나타났다. 본 연구결과는 옥상녹화의 온도저감 효과를 정량적으로 제시하고 있어, 향후 기후변화 대응 및 적응 전략적 수립에 기여할 수 있을 것으로 판단된다.

  • PDF

Evaluating Changing Trends of Surface Temperature in Winter according to Rooftop Color using Remotely Sensed Thermal Infrared Image (원격 열화상을 이용한 지붕색상별 겨울철 표면온도 변화추세 비교 평가)

  • Ryu, Taek Hyoung;Um, Jung Sup
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.1
    • /
    • pp.27-37
    • /
    • 2013
  • A roof surface temperature monitoring, utilizing remotely sensed thermal infrared image has been specifically proposed to explore evidential data for heating load in winter by cool roof. The remotely sensed thermal infrared image made it possible to identify area-wide patterns of changing trends of surface temperature according to rooftop color (white, black, blue, green) which cannot be acquired by traditional field sampling. The temperature difference of cool roof having a higher solar reflectance were ranged from $3^{\circ}C$ up to $9^{\circ}C$, compared to the general roofs. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate since up to $18.46^{\circ}C$ difference in cool roof, compared to the general roofs in summer were already identified in Seoul, South Korea. It is anticipated that this research output could be used as a valuable reference in identifying heating load in winter by cool roof since an objective monitoring has been proposed based on the area-wide measured, fully quantitative performance of remotely sensed thermal infrared image.

Analysis of Surface Temperature Characteristics by Land Surface Fabrics Using UAV TIR Images (UAV 열적외 영상을 활용한 피복재질별 표면온도 특성 분석)

  • SONG, Bong-Geun;KIM, Gyeong-Ah;SEO, Kyeong-Ho;LEE, Seung-Won;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.3
    • /
    • pp.162-175
    • /
    • 2018
  • The purpose of this study was to analyze the surface temperature of surface fabrics using UAV TIR images, to mitigate problems in the thermal environment of urban areas. Surface temperature values derived from UAV images were compared with those measured in-situ during the similar period as when the images were taken. The difference in the in-situ measured and UAV image derived surface temperatures is the highest for gray colored concrete roof fabrics, at $17^{\circ}C$, and urethane fabrics show the lowest difference, at $0.3^{\circ}C$. The experiment power of the scatter plot of in-situ measured and UAV image derived surface temperatures was 63.75%, indicating that the correlation between the two is high. The surface fabrics with high temperature are metal roofs($48.9^{\circ}C$), urethane($43.4^{\circ}C$), and gray colored concrete roofs($42.9^{\circ}C$), and those with low temperature are barren land($30.2^{\circ}C$), area with trees and lawns($30.2^{\circ}C$), and white colored concrete roofs($34.9^{\circ}C$). These results show that accurate analysis of the thermal characteristics of surface fabrics is possible using UAV images. In future, it will be necessary to increase the usability of UAV images via comparison with in-situ data and linkage to satellite imagery.

The Characteristics of Retention and Evapotranspiration in the Extensive Greening Module of Sloped and Flat Rooftops (저토심 경사지붕과 평지붕 녹화모듈의 저류 및 증발산 특성)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.107-116
    • /
    • 2013
  • This study was undertaken to investigate the characteristics of retention and evapotranspiration in the extensive greening module of sloped and flat rooftops for stormwater management and urban heat island mitigation. A series of 100mm depth's weighing lysimeters planted with Sedum kamtschaticum. were constructed on a 50% slope facing four orientations(north, east, south and west) and a flat rooftop. Thereafter the retention and evapotranspiration from the greening module and the surface temperature of nongreening and greening rooftop were recorded beginning in September 2012 for a period of 1 year. The characteristics of retention and evapotranspiration in the greening module were as follows. The water storage of the sloped and flat greening modules increased to 8.7~28.4mm and 10.6~31.8mm after rainfall except in the winter season, in which it decreased to 3.3mm and 3.9mm in the longer dry period. The maximum stormwater retention of the sloped and flat greening modules was 22.2mm and 23.1mm except in the winter season. Fitted stormwater retention function was [Stormwater Retention Ratio(%)=-18.42 ln(Precipitation)+107.9, $R^2$=0.80] for sloped greening modules, and that was [Stormwater Retention Ratio(%)=-22.64 ln(X)+130.8, $R^2$=0.81] for flat greening modules. The daily evapotranspiration(mm/day) from the greening modules after rainfall decreased rapidly with a power function type in summer, and with a log function type in spring and autumn. The daily evapotranspiration(mm/day) from the greening modules after rainfall was greater in summer > spring > autumn > winter by season. This may be due to the differences in water storage, solar radiation and air temperature. The daily evapotranspiration from the greening modules decreased rapidly from 2~7mm/day to less than 1mm/day for 3~5 days after rainfall, and that decreased slowly after 3~5 days. This indicates that Sedum kamtschaticum used water rapidly when it was available and conserved water when it was not. The albedo of the concrete rooftop and greening rooftop was 0.151 and 0.137 in summer, and 0.165 and 0.165 in winter respectively. The albedo of the concrete rooftop and greening rooftop was similar. The effect of the daily mean and highest surface temperature decrease by greening during the summer season showed $1.6{\sim}13.8^{\circ}C$(mean $9.7^{\circ}C$) and $6.2{\sim}17.6^{\circ}C$(mean $11.2^{\circ}C$). The difference of the daily mean and highest surface temperature between the greening rooftop and concrete rooftop during the winter season were small, measuring $-2.4{\sim}1.3^{\circ}C$(mean $-0.4^{\circ}C$) and $-4.2{\sim}2.6^{\circ}C$(mean $0.0^{\circ}C$). The difference in the highest daily surface temperature between the greening rooftop and concrete rooftop during the summer season increased with an evapotranspiration rate increase by a linear function type. The fitted function of the highest daily surface temperature decrease was [Temperature Decrease($^{\circ}C$)=$1.4361{\times}$(Evapotranspiration rate(mm/day))+8.83, $R^2$=0.59]. The decrease of the surface temperature by greening in the longer dry period was due to sun protection by the sedum canopy. The results of this study indicate that the extensive rooftop greening will assist in managing stormwater runoff and urban heat island through retention and evapotranspiration. Sedum kamtschaticum would be the ideal plant for a non-irrigated extensive green roof. The shading effects of Sedum kamtschaticum would be important as well as the evapotranspiration effects of that for the long-term mitigation effects of an urban heat island.

Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof (평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서)

  • Ryu, Taek Hyoung;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.

The Effect of Roofing Materials for Using Harvested Rainwater (집수빗물이용을 위한 지붕면 재질의 영향)

  • Lee, Ju Young;Kim, Tschung-Il;Kim, Hyunwoo;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.623-629
    • /
    • 2012
  • The objective was to evaluate the quality of harvested rainwater of the roofing materials used and the presence of lichens/mosses on the roofing surface. This experiment was studied in the field where five pilot structures with different roofing materials (i.e., wooden shingle tiles, wooden shingle tiles (including mosses), concrete tiles, clay tiles [Gi-Wa] and slate tiles) were installed. As a result, the clay tiles [Gi-Wa] was found to be the most suitable for rainwater harvesting applications. It was due to the disinfection from ultraviolet light and high temperature according to characteristic of roofing materials. Comparison with quality of rainwater on that wooden shingle tiles with and without including mosses, which may affect the concentration of and wooden shingle tiles including mosses, mosses may affect concentration of TOC, nitrate, and sulfate. Additionally, the average concentration of asbestos was determined to be measured at $0.002/cm^3$ for the slate tiles. The value satisfied with it met the Ministry of Environment's Multi-use facility standard and Ministry of Labor's Office standard ($0.01/cm^3$).

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

Comparison of Rooftop Surface Temperature and Indoor Temperature for the Evaluation of Cool Roof Performance according to the Rooftop Colors in Summer: Using Thermal Infrared Camera Mounted on UAV (옥상 색상에 따른 쿨루프 성능평가를 위한 여름철 옥상 표면 및 실내온도 비교 분석 : 무인항공기에 장착된 열적외선 카메라를 이용하여)

  • Lee, Ki Rim;Seong, Ji Hoon;Han, You Kyung;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2019
  • The intensity and the number of days of high temperature occurrence are also high and record heat occurred. In addition, the global warming phenomenon is intensifying globally, and especially in South Korea, the urban heat island phenomenon is also occurring due to rapid urbanization due to rapid industrial development. As the temperature of the city rises, it causes problems such as the comfort of the residential living and the cooling load. In this study, the cool roof performance is evaluated according to the roof color to reduce these problems. Unlike previous studies, UAV(Unmanned Aerial Vehicle) thermal infrared camera was used to obtain the surface temperature (white, grey, green, blue, brown, black) according to the rooftop color by remote sensing technique. As a result, the surface temperature of white color was $11{\sim}20^{\circ}C$ lower than other colors. Also air conditioning temperature of white color was $1.5{\sim}4.4^{\circ}C$ lower than other colors and the digital thermometer of white color was about $1.5{\sim}3.5^{\circ}C$ lower than other colors. It was confirmed that the white cool roof performance is the best, and the UAV and the thermal infrared camera can confirm the cool roof performa.

Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain (온실지붕 차광과 수막 수준에 따른 냉방효과 분석)

  • Kim, Young-Bok;Park, Joong-Chun;Lee, Seung-Kyu;Kim, Sung-Tae;La, Woo-Jung;Huh, Moo-Ryong;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.306-316
    • /
    • 2006
  • In this study, the effect of the shade level, water flow rate applied to the shades and the temperature of water on the greenhouse cooling was investigated depending on the shade level of 0, 35, 55, 75%, and water flow rate and water temperature by the test on the small wooden frames to find out the low cost cooling method. With increasing of the dry bulb temperature of outside air, the dry bulb temperature in the wooden frames increased. For the frames with the shade and water, inside temperatures of the frames were lower of -0.2$\sim$-1.2$^{\circ}C$ than the temperature of the outside air and higher than the water temperature. For the frames without water, inside temperatures of the frames were higher of 1.7$\sim$4$^{\circ}C$ than the outside and not affected by the shade level very much. The water flow rate and the temperature of the water were not the important factors to decrease the inside temperatures in the frames. The black globe temperature became lower with increasing of shade level. The shade frames with water curtain showed the best cooling effect because of reducing thermal radiation and cooling the plastic film cover. The surface temperatures of the plastic film cover for the water supplied modules became lower with increasing of the shade level. The relative humidity was decreased with the dry bulb temperature in the frame increasing and not affected by the dry bulb temperature of the outside air for the frames with the shade and water.