• Title/Summary/Keyword: 중합체

Search Result 395, Processing Time 0.024 seconds

Characteristics of Ring-Opening Isomerization Polymerization of [4.3.0] Cyclic Pseudoureas ([4.3.0] 환상 유사 우레아의 이성화 개환중합과 특성평가)

  • Lee, Chan-Woo;Chung, Jin-Do
    • Polymer(Korea)
    • /
    • v.35 no.4
    • /
    • pp.308-313
    • /
    • 2011
  • The ring-opening isomerization polymerization behavior of 2,5,6,7-tetrahydro-3H-imidazo[2,1-b] [1,3] oxazine(TII) has been studied under various conditions. The present study aimed at improving the low polymerizability of the above monomer (six-membered ring) up to a level comparable to that of 2,5,6-tetrahydroimidazo[2,1-b] [l,3] oxazole(TIO) (five-membered ring). The optimum result could be observed when methyl trifluoromethanesulfonate(MeOTf) and nitrobenzene were used as an initiator and a solvent in the polymerization at $60^{\circ}C$ for 24 h. Polymers were confirmed by$^1H$ NMR과$^{13}C$ NMR, and m measurements. The molecular weight obtained by gel permeation chromatography (GPC) corresponded to the molecular weight theoretically calculated from the feed ratio. The melting temperature ($T_m$) of TII was conspicuously different from that of TIO, because of the difference in the alkyl group.

Performance of Annealed Polyacrylonitrile Nanofiltration Membrane (아닐링된 폴리아크릴로니트릴 나노막의 성능)

  • Lee Kew-Ho;Kim In-Chul
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • The integrally skinned asymmetric PAN ultrafiltration membranes were annealed for reducing the pore size. The effect of the chemical structure of two PAN polymers (homo- and copolymer) on annealing was investigated. The annealing of PAN polymer was strongly affected by the chemical structure of the polymer. In other words, the annealing effect of the copolymer was much larger than that of the homopolymer due to its less rigid structure of the main chain. Before annealing, the membranes were usually preheated in water in terms of the complete removal of remained solvents in the membranes. The annealing effect was bigger when no preheating. However, the preheating of the membrane before annealing at high temperatures leads to an increase in the pore size of membranes. The surface of the membranes was slightly negative and the salt rejection of PAN nanofiltration membrane was in the following order: R(Na₂SO₄) > R(NaCl) > R(MgSO₄) > R(CaCl₂). This salt rejection behavior could be explained by the Donnan equilibrium and the electroneutrality.

Characteristics of Water Contamination and Precipitates of Acid Mine Drainage, Bongyang Abandoned Coal Mine, Danyang, Chungbuk Province with Emphasis on Fe and Al behaviors (충북 단양 봉양폐탄광 산성광산배수의 수질오염과 침전물의 특성: 철, 알루미늄의 거동을 중심으로)

  • Choo, Chang Oh;Lee, Jin Kook
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.163-183
    • /
    • 2019
  • We investigated acid mine drainage (AMD) of Bongyang abandoned coal mine, Danyang, Chungbuk Province with emphasis on geochemical contaminants in AMD and precipitates using chemical analyses, XRD, SEM, IR, and $^{27}Al$ NMR. Water chemistry changes with pH and oversaturation of chemical species. According to calculation of saturation index, the AMD is saturated with various Fe, Al minerals. Orange or orcher precipitates are composed of schwertmannite and goethite, associated with Leptothrix orchracea bacteria, whereas whitish precipitates are composed mostly of alumimous minerals such as basaluminite with poor crystallinity. The whitish precipitates include trace $Al_{13}$-Tridecamer. It is important to control the precipitation and solubility of aluminous species for ensuring remediation and control for the AMD discharged from the Bongyang abandoned coal mine.

Oil Leakage Prediction through Cut Part of Double Elastomeric Seal (이중 탄성중합체 시일의 절단부 오일누유 예측)

  • Taek-Sung Lee;Yeon-Hi Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2023
  • The rotary joint connecting the upper and lower structures of construction machinery and special vehicles transmits hydraulic pressure as the shaft and housing rotate, and multiple seals are assembled to prevent oil leakage into the oil flow channel. Because the seal material is rigid and difficult to assemble, we sought a method to assemble it after cutting. The shapes of the cutting surface are L-shaped and / shaped, and the leakage standard when hydraulic pressure is applied is the contact pressure generated on the cutting surface. The structure and material of the seal are composed of a double elastomer, and nonlinear contact structural analysis is performed when only the high-rigidity PE material is cut. Studies have shown that the shorter the cutting length, the better the leakage prevention and the higher the possibility of leakage to the bottom surface where NBR and PE come into contact rather than the top surface where the PE and the housing come into contact.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

The Effects of Chungkookjang Biopolymer on Blood Glucose and Serum Lipid Lowering in Streptozotocin-Induced Diabetic Rats (청국장 점질성 중합체의 첨가 식이가 Streptozotocin 유발 당뇨쥐의 혈당 및 혈청지질 감소에 미치는 영향)

  • Kim, Seong-Ho;Jung, So-Hyoung;Kim, In-Ho;Lee, Yu-Soon;Lee, Jin-Man;Kim, Jong-Guk;Lee, Myung-Chul;Choi, Mi-Ja;Kim, Duk-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • The purpose of this study was to investigate the effects of Chungkookjang viscous biopolymer supplementation on blood glucose and serum lipid-lowering in Streptozotocin (STZ)-induced diabetic rats. The rats were divided into three experimental groups; a normal group (N), diabetic control group (D), and a diabetic group with the supplementation of Chungkookjang viscous biopolymer (DCB). The groups were given experimental diets for four weeks. The normal group (C) was fed a casein-based diet, and the Chungkookjang viscous biopolymer group (DCB) received 3% biopolymer added to the casein-based diet. In the diabetic group (D), food intake increased significantly, but weight gain decreased significantly. The food efficiency ratio was significantly lower in the diabetic group. Liver weight increased significantly in the D group as compared to the N group. However, the DCB group showed a significant decrease in liver weight when compared to the D group. Blood glucose decreased significantly in the DCB group after receiving the experimental diet for four weeks, as compared to the diabetic control (p<0.05). Serum triglyceride levels were significantly lower in the DCB group than in the D group, whereas HDL-cholesterol levels were significantly higher (p<0.05). Total cholesterol was decreased in DCB group, but there were no significant differences. Also, LDL-cholesterol level was not significantly different among the experimental groups. Hepatic triglyceride and cholesterol were lower in the DCB group with no significant differences among groups. These results indicate that dietary supplementation of Chungkookjang viscous biopolymer improved glucose lowering and lipid metabolism in diabetic rats.

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Composition Studies on the Aromatic Tobacco Varieties (Nicotiana tabacum L. ) : II. Characteristics of Headspace Vapors (향끽미종 잎담배 성분조성에 관한 연구 II. 헤드스페이스 휘발성 유기성분의 특성 조사)

  • Kim, Kyoung-Rae;Lee, Un-chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1981
  • Volatile compounds in the headspace vapors of five aromatic tobacco varieties have been examined us ins the polymer adsorption method and high- resolution glass capillary gas chromatography. The gas chromatographic profiles thus obtained were compared, and the aroma composition was found to be characteristic of each tobacco sample with significant differences in the concentrations of major components.

  • PDF

DEPOSITION OF BUFFER LAYER USING PLASMA POLYMERIZATION TECHNQUE FOR OLED DEVICE (플라즈마 중합법에 의한 OLED 소자용 버퍼층의 제작)

  • Lim, J.S.;Kim, H.G.;Kim, Y.H.;Lim, Y.C.;Jung, G.H.;Lee, B.S.;Shin, P.K.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1567-1569
    • /
    • 2004
  • 유기발광 소자의 전공 수송층 재료로 많이 쓰이고 있는 N,N'-diphenyl-N,N'-(3-methylphenyl)-1,1'-biphenyl-4-4'-diamine(TPD)는 OLED소자가 연속적으로 작동하게 되면 TPD박막이 결정화되는데, 이러한 결정화는 디스플래이 소자에 dark spot(흑점)의 문제점을 가져왔다. 이러한 원인을 제거하기 위해서 ITO위에 PolyThiophene을 완충층으로 제작함으로써, OLED 소자의 효율에 미치는 영향은 크다고 할수 있다. 자체 제작한 플라즈마 중합장치의 중합조건과 중합체 PolyThiophene의 분자구조를 알아보았다.

  • PDF

Synthesis of CHBM-DVB Ion Exchanger and It's Ion Exchange Behavior (CHBM-DVB 이온교환체의 합성과 그의 이온교환작용)

  • Dong Won Kim;Kong Soo Kim;Nam Kee Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.164-171
    • /
    • 1985
  • The salicylic acid-formaldehyde condensed copolymer (SAF) and the 3-carboxy-4-hydroxy benzyl methacrylate divinylbenzene copolymer (CHBM-DVB) were synthesized. The capacities of SAF and CHBM-DVB ion exchangers were 4.6meq/g and 3.9 meq/g, respectively. The adsorption of several heavy metal ions on these weakly acidic ion exchangers and the property of ion exchanger were discussed. The distribution coefficients in hydrochloric acid solution and the elution behavior of several heavy metal ions were also discussed.

  • PDF