• Title/Summary/Keyword: 중성자 방사선

Search Result 229, Processing Time 0.023 seconds

Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation (방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.571-578
    • /
    • 2001
  • To evaluate if the apoptotic fragment assay could be used to estimate the dose prediction after radiation exposure, we examined apoptotic mouse crypt cells per 1,000 cells after whole body $^{60}Co$ $\gamma$-rays and 50MeV ($p{\rightarrow}Be^+$) cyclotron fast neutron irradiation in the range of 0.25 to 1 Gy, respectively. The incidence of apoptotic cell death rose steeply at very low doses up to 1 Gy, and radiation at all doses tigger rapid changes in crypt cells in stem cell region. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for the data of apoptotic fragments was obtained by the linear-quadratic model $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$) after $\gamma$-rays irradiation, while $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$) after neutrons in mice. The dose-response curves were linear-quadratic, and a significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic crypt cells with increasing dose. Both the time course and the radiation dose-response curve for high and low linear energy transfer (LET) radiation modalities were similar. The relative biological effectiveness (RBE) value for crypt cells was 2.072. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morpholoigcal findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis in crypt cells could be a useful in vivo model for studying radio-protective drug sensitivity or screening test, microdosimetric indicator and radiation-induced target organ injury. Since the apoptotic fragment assay is simple, rapid and reproducible in the range of 0.25 to 1 Gy, it will also be a good tool for evaluating the dose response of radiation-induced organ damage in vivo and provide a potentially valuable biodosimetry for the early dose prediction after accidental exposure.

  • PDF

Study on the Application of Soft Magnetic Material for Effective Neutron Shielding (효과적인 중성자 차폐를 위한 경량 연자성 물질 활용방안 연구)

  • Yeongchan Kim;Changwoo Kang
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.93-100
    • /
    • 2023
  • This study analyzes the neutron shielding performance of Soft Magnetic Material and proposes a military application. In general, the military protection facility has been constructed with thick concrete, so Soft Magnetic Material, consisting of boron, was used with concrete in this study. To do so, Monte-Carlo N-Particle (MCNP) was applied to simulate the Watt-fission neutron spectrum of 235U and 239Pu. As a result, a configuration of polyethylene and Soft Magnetic Material is evaluated about four times better than borated polyethylene concerning the atomic weight of boron inside each shielding material. Also, when a nuclear weapon explosion is simulated in MCNP, 1 mm of Soft Magnetic Material with 20 cm of concrete shows about 55% more additional neutron shielding performance compared to when Soft Magnetic Material is not used. In this work, the neutron shielding performance of Soft Magnetic Material could be identified and Soft Magnetic Material would be useful for neutron shielding if applicable to concrete structure.

A Study of Targetry Activation and Dose Analysis of PET Cyclotron Using Monte Carlo Simulation (몬테카를로 모의 모사를 이용한 의료용 사이클로트론의 Targetry 방사화 및 피폭선량 분석)

  • Jang, Donggun;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.565-573
    • /
    • 2018
  • Cyclotron for medical purposes generates nuclear reaction by accelerating protons in high speed, in order to produce radiopharmaceuticals, and unnecessary neutrons are generated through such nuclear reaction. Neutrons cause activation in the parts of cyclotron which then cause exposure to radiation for people working in the field. This study, in that regard, aims to analyze exposure level by finding out the degree of activation of aluminum body, silver body, and havar foil which are the parts of Targetry where the nuclear reaction takes place. The results of the experiment showed that aluminum body and silver body had no problems re-using them as the energy and half-life of activated nuclides were small and short, making the affect on the people working in the field extremely low. However for havar foil, its activated nuclides had a high level of energy which resulted in high level of affect to the people working in the field. The activation factors of the cyclotron were analyzed, and the results showed that the Havar foil was activated the most among the targetry parts, and greatly exposed workers due to regular replacement, and needed special management as radioactive waste.

Evaluation of Machine Learning Methods to Reduce Stripe Artifacts in the Phase Contrast Image due to Line-Integration Process (선적분에 의한 위상차 영상의 줄무늬 아티팩트 감소를 위한 기계학습법에 대한 평가)

  • Kim, Myungkeun;Oh, Ohsung;Lee, Seho;Lee, Seung Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.937-946
    • /
    • 2020
  • The grating interferometer provides the differential phase contrast image of an phase object due to refraction of the wavefront by the object, and it needs to be converted to the phase contrast image. The line-integration process to obtain the phase contrast image from a differential phase contrast image accumulates noise and generate stripe artifacts. The stripe artifacts have noise and distortion increases to the integration direction in the line-integrated phase contrast image. In this study, we have configured and compared several machine learning methods to reduce the artifacts. The machine learning methods have been applied to simulated numerical phantoms as well as experimental data from the X-ray and neutron grating interferometer for comparison. As a result, the combination of the wavelet preprocessing and machine learning method (WCNN) has shown to be the most effective.

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF

Intercomparison Study of the Neutron Personnel Dosemeters (중성자 개인선량계 상호비교)

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.49-57
    • /
    • 1998
  • Domestic intercomparison study of the neutron personnel dosemeters was performed for the first time in Korea. Thirteen types of neutron dosemeters from twelve institutions took part in this intercomparison study and the $D_2O$ moderated Cf-252 source of KAERI was used for irradiation. Eight of the fifteen dosemeters submitted by each participant were divided into two groups and each group was irradiated with different doses of the simulated mixed fields of neutron and gamma. The participants assessed their dosemeter reading in terms of the personal dose equivalent, Hp(10), for both neutron and gamma dose. The ratio of the reported dose equivalent to the delivered dose equivalent for comparison between participants ranged from 0.55 to 1.34 for neutron, from 0.54 to 1.32 for gamma and from 0.75 to 1.20 for total dose. This intercomparison results show that all dosemeter processors, especially for neutron category, are able to pass the personnel dosemeter performance test which shall be enforced according to the ordinance of the MOST, No. 96-6.

  • PDF

The Effect of Final Heat Treatment and Welding on Irradiation Growth of Zircaloy-4 (최종열처리와 용접Zircaloy-4의 방사선조사 성장에 미치는 영향)

  • Im, Gap-Sun;Han, Jeong-Ho;Jeong, Yong-Hwan;Lee, Deok-Hyeon;Park, Gi-Seong;Kim, Yeong-Seok;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.3 no.1
    • /
    • pp.65-71
    • /
    • 1993
  • Abstract The effect of final heat treatment and welding on the irradiation growth of Zircaloy-4 was investigated. As a simulation for neurtron irradiation, accelerated proton beam with the energy of 3.5MeV was used up to the proton fluence of 9.8 ${\times}{10^{21}}$p/$m^2$ in the present study. It was found that irradiation growth of the annealed specimen was the highest and that of the ${\beta}$-quenched specimen was the samllest among the present specimens. The magnitude of irradiation growth of the present specimens decreased by welding. The difference in the magnitude of irradiation growth of the present specimens with different final heat treatment and the effect of welding on it were quantitatively analyzed in terms of crystallographic texture by using Kearns number, f, which was calculated from the x-ray diffraction data.

  • PDF

Track Distiribution of Recoil Protons in PN-3 Dosimeters Etched in NaOH Solution (NaOH 용액에 의해 부식된 PN-3 선량측정계에서의 되튕긴 양성자의 궤적 분포)

  • Yoo, Done-Sik;Sim, Kwang-Souk
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.129-139
    • /
    • 1991
  • The method of etching tracks in PN-3 dosimeter has been applied to tracks of recoil protons from a neutron source. Both the etch and the detection response of PN-3 has been studied as a function of etched-track diameters against various parameters. We could obtain very useful informations about charge, energy, and mass of particles and the relationship between the track etching rate and the track forming procedure in order to analyze the particle recorded in the solid state track detector. The best etching condition could be found by means of changing the etching circumstances for various energies and particles in order to detect the charged particle accurately. It could be influenced widely that the polymer plastic detector could develep the detecting technique for the low energy level neutron and could be used as a neutron dosimeter in the radiation field such as the nuclear power station, the medical institute and the nondtructive testing institute.

  • PDF

The Development Study of A Manganese Sulphate Bath System ($MnSO_4$용액조 장치 개발 연구)

  • Hwang, Sun-Tae;Lee, Kyung-Ju;Choi, Kil-Oung;Kim, Won-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.70-76
    • /
    • 1986
  • In order to establish the national standards of neutron measurements, a manganese sulphate ($MnSO_4$) bath system was developed under the IAEA technical support. This bath system was made up of a spherical s.s. 316 L bath, of 3.5 mm thick and of 125 cm internal diagmeter, filled with a manganese sulphate solution, a solution circulating system, and a $^5Mn\;{\gamma}-ray$ monitoring system. The solution pumped from the bath was introduced into a Marinelli beaker-type monitor vessel which was equipped with two seperate detectors, $3.8cm{\phi}{\times}3.8cm$ NaI(T1) crystals. The performance of the system were tested using the neutron sources, $^{241}Am-Be\;and\;^{252}Cf$, mounted at the center of the bath. From the decay curve analysis of $^{56}Mn$ activity, neutron emission rate of $^{252}Cf$ by the comparative method was obtained to be $3.71{\times}10^7\;n/s\;per\;50{mu}g$ as of November 15, 1985.

  • PDF

Dosimetric Quantities for 300 keV Neutrons (300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.37-43
    • /
    • 1986
  • Dosimetric quantities for 300 keV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ Shallow dose equivalent index $H_{I,s}:2.08{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(0.07):1.7{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ Effective quality factor $\bar{Q}^*(10):12.4$

  • PDF