• 제목/요약/키워드: 주상

검색결과 1,474건 처리시간 0.029초

Characteristics of the construction process, the history of use and performed rituals of Gyeongungung Heungdeokjeon (경운궁 흥덕전의 조영 및 사용 연혁과 설행된 의례의 특징)

  • LIM, Cholong;JOO, Sanghun
    • Korean Journal of Heritage: History & Science
    • /
    • 제55권1호
    • /
    • pp.281-304
    • /
    • 2022
  • Heungdeokjeon was the first pavilion built on the site of Sueocheong during the expansion of Gyeongungung. In this study, we tried to clarify the specific construction process of Heungdeokjeon, which was used for various purposes such as the copy location for Portraits of ancestors, temporary enshrinement site, and the funeral building for the rest of the body, which is Binjeon. In addition, we tried to confirm the historical value based on the characteristics derived by the history of the building and the rituals performed. Heungdeokjeon began to be built in the second half of 1899, and is estimated to have been completed between mid-February and mid-March 1900. It was a ritual facility equipped with waiting rooms for the emperor and royal ladies as an annex. The relocation work was planned in April 1901 and began in earnest after June, and it was closely linked to the construction of attached buildings of Seonwonjeon. In addition, comparing the records on the construction and relocation cost of Heungdeokjeon with those related to the reconstruction of Seonwonjeon, it was confirmed that annex buildings of Heungdeokjeon were relocated and used as annex buildings of Seonwonjeon. The characteristics identified in the process of Heungdeokjeon used as a place to copy portraits are as follows. First, it was used as a place to copy portraits twice in a short period of time. Second, it was the place where the first unprecedented works were carried out in relation to the copying of portraits. Third, the pavilion, which was specially built for imperial rituals, was used as a place to copy portraits. Since then, it has been used as a funeral building for the rest of the body, and features different from those of the previous period are identified. It was the building dedicated to rituals for use as Binjeon, and was also a multipurpose building for copying portraits. In other words, Heungdeokjeon, along with Gyeongbokgung Taewonjeon, is the building that shows the changes in the operation of Binjeon in the late Joseon Dynasty. Characteristics are also confirmed in portrait-related rituals performed at Heungdeokjeon. The first is that Jakheonlye was practiced frequently in a short period of time. The second is that the ancestral rites of Sokjeolje and Bunhyang in Sakmangil, which are mainly held in the provincial Jinjeon, were identified. This is a very rare case in Jinjeon of the palace. The last is that Jeonbae, jeonal, and Bongsim were implemented mutiple times. In conclusion, Heungdeokjeon can be said to be a very symbolic building that shows the intention of Gojong, who valued imperial rituals, and the characteristics of the reconstruction process of Gyeongungung.

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • 제56권1호
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Estimation of Dynamic Material Properties for Fill Dam : II. Nonlinear Deformation Characteristics (필댐 제체 재료의 동적 물성치 평가 : II. 비선형 동적 변형특성)

  • Lee, Sei-Hyun;Kim, Dong-Soo;Choo, Yun-Wook;Choo, Hyek-Kee
    • Journal of the Korean Geotechnical Society
    • /
    • 제25권12호
    • /
    • pp.87-105
    • /
    • 2009
  • Nonlinear dynamic deformation characteristics, expressed in terms of normalized shear modulus reduction curve (G/$G_{max}-\log\gamma$, G/$G_{max}$ curve) and damping curve (D-$\log\gamma$), are important input parameters with shear wave velocity profile ($V_s$-profile) in the seismic analysis of (new or existing) fill dam. In this paper, the reasonable and economical methods to evaluate the nonlinear dynamic deformation characteristics for core zone and rockfill zone respectively are presented. For the core zone, 111 G/$G_{max}$ curves and 98 damping curves which meet the requirements of core material were compiled and representative curves and ranges were proposed for the three ranges of confining pressure (0~100 kPa, 100 kPa~200 kPa, more than 200 kPa). The reliability of the proposed curves for the core zone were verified by comparing with the resonant column test results of two kinds of core materials. For the rockfill zone, 135 G/$G_{max}$ curves and 65 damping curves were compiled from the test results of gravelly materials using large scale testing equipments. The representative curves and ranges for G/$G_{max}$ were proposed for the three ranges of confining pressure (0~50 kPa, 50 kPa~100 kPa, more than 100 kPa) and those for damping were proposed independently of confining pressure. The reliability of the proposed curves for the rockfill zone were verified by comparing with the large scale triaxial test results of rockfill materials in the B-dam which is being constructed.

Natural Monument Cretaceous Stromatolite at the Daegu Catholic University, Gyeongsan: Occurrences, Natural Heritage Values, and Plan for Preservation and Utilization (천연기념물 경산 대구가톨릭대학교 백악기 스트로마톨라이트: 산상, 자연유산적 가치 및 보존·활용 방안)

  • KONG Dal-Yong;LEE Seong-Joo
    • Korean Journal of Heritage: History & Science
    • /
    • 제56권3호
    • /
    • pp.214-232
    • /
    • 2023
  • Stromatolite at the Daegu Catholic University, Gyeongsan was designated as a natural monument in December 2009 because it was very excellent in terms of rarity, accessibility, preservation and scale. From the time of designation, the necessity of confirming the lateral extension of the stromatolite beds with the excavation of the surrounding area, and preparing a preservation plan was raised. Accordingly, the Cultural Heritage Administration conducted an investigation of the scale, production pattern, and weathering state of stromatolites with an excavation from April to December 2022, and based on this, suggested natural heritage values and conservation and use plans. The excavation was carried out in a 1,186m2 area surrounding the exposed hemispherical stromatolite (approximately 30m2). Stromatolites are continuously distributed over the entire excavation area, and hemispherical stromatolites predominate in the eastern region, and the distribution and size of hemispherical domes tend to decrease toward the west. These characteristics are interpreted as a result of long-term growth in large-scale lakes, where stratiform or small columnar domes continued to grow and connect with each other, finally forming large domes. Consequently, large and small domes were distributed on the bedding plane in clusters like coral reefs. The growth of plants and lichens, as well as small-scale faults and joints developed on the stromatolite bedding surface, is the main cause of accelerated weathering. However, preservation treatment with chemicals as with dinosaur footprints or dinosaur egg fossil sites is not suitable due to the characteristics of stromatolites, and preservation with the installation of closed protection facilities should be considered. This excavation confirmed that the distribution, size and value of stromatolites are much larger and higher than at the time of designation as a natural monument. Therefore, additional excavation of areas by experts that could not be excavated due to the discovery of buried cultural properties (stone chamber tombs) and reexamination of the expansion designation of natural monuments are required.

Gut Microbiome and Gut Immunity in Broiler Chickens Fed Allium hookeri Root Powder from Day 10 to 28 (육계 사료 내 삼채뿌리분말 첨가가 장내 미생물 및 장관면역에 미치는 영향)

  • Woonhak Ji;Inho Cho;Sang Seok Joo;Moongyeong Jung;Chae Won Lee;June Hyeok Yoon;Su Hyun An;Myunghoo Kim;Changsu Kong
    • Korean Journal of Poultry Science
    • /
    • 제50권3호
    • /
    • pp.171-185
    • /
    • 2023
  • This study was conducted to investigate the effects of supplementation of Allium hookeri (AH) root powder on the gut microbiome, immunity, and health in broiler chickens fed experimental diets from d 10 to 28. A total of 60 10-day-old Ross 308 broilers were weighed and assigned to two dietary treatments with 5 birds per cage in a randomized complete block design based on body weight. The two experimental diets consisted of a control diet based on corn-soybean meal and the control diet supplemented with 0.3% AH root powder. All birds were fed ad libitum with experimental diets and water for 18 d. At 28 d, two birds near the median weight from each cage were selected for cecal content and small intestinal tissue sample collection. The addition of AH changed the gut microbiome by increasing probiotic candidate beneficial bacteria such as Enterococcaceae, Lactobacillaceae, Limosilactobacillus, Cuneatibacter, and Ruminoccoides. Regarding gut immunity, the supplementation of AH resulted in changes in intestinal immune cells, including reduced CD3+CD4+ T cells, which are a type of helper T cell, in the small intestine of birds (P=0.049). Additionally, there was a tendency to increase the expression of antioxidant function-related gene such as GPX2 (P=0.060), but no significant changes were observed in cytokines such as IL1b, IL6, and IL10. Overall, the addition of AH root powder may have positive effects on the microbiome of the chickens. This may help promote gut health in broiler chickens at the age of d 10 to 28.

Paprika Damping-off Outbreak Caused by Fusarium oxysporum Contaminated Seeds in Cheorwon Province in 2023 (2023 파프리카 종자의 Fusarium oxysporum 오염에 의한 철원지역 파프리카 모잘록병 대발생)

  • Miah Bae;Namsuk Kim;Sang Woo Kim;Sangyeon Ju;Byungyeon Kim;Soo Man Hwang;MeeKyoung Kim;Mi-Ri Park
    • Research in Plant Disease
    • /
    • 제30권1호
    • /
    • pp.26-33
    • /
    • 2024
  • In 2023, symptoms like damping-off disease were observed in 74 paprika growing in greenhouses in Cheorwon-gun, Gangwon-do, Korea. In this study, we tried to find the cause of the damping-off disease outbreak. We collected symptomatic seedlings and observed the typical crescent-shaped conidia of Fusarium oxysporum by microscope. To confirm the presence of F. oxysporum in the samples, polymerase chain reaction was performed using primers specific for F. oxysporum; the resulting sequence showed 99.11% identity with F. oxysporum. To confirm the pathogenicity of the F. oxysporum (CW) isolated from the samples, healthy paprika plants were inoculated with F. oxysporum CW and damping-off symptoms were observed 2 weeks later. To investigate whether the damping-off disease outbreak in Cheorwon-gun was caused by F. oxysporum-contaminated seeds, 100 paprika seeds were disinfected and placed in Murashige and Skoog medium. Typical pink F. oxysporum hyphae were found only in control non-disinfected seeds. An 18S rRNA-based and a TEF genebased phylogenetic analysis showed that the F. oxysporum CW isolate was not grouped with a F. oxysporum isolate reported from Cheorwon-gun in 2019. This study is the first report that an outbreak of damping-off disease in paprika in Cheorwon-gun, Gangwon-do, Korea, was caused by contamination of F. oxysporum seeds.

A Study on How to Improve Local Government Ordinances to Promote Korean Heritage Information Management : Focusing on the relation aspect of Korean Heritage laws and ordinances (국가유산 정보 관리 활성화를 위한 광역자치단체 조례의 개선 방향 연구 : 국가유산 관련 법과 조례의 관계적 성격을 중심으로)

  • GANG Bobae;JOO Sanghun
    • Korean Journal of Heritage: History & Science
    • /
    • 제57권3호
    • /
    • pp.140-160
    • /
    • 2024
  • The implementation of the "Basic Law on Korean Heritage" on May 17, 2024, brought about significant changes in the operation of Korean heritage-related ordinances in 17 local governments. This study specifically analyzes the production, collection, and information transfer of Korean heritage information between the Korean Heritage Service and local governments, focusing on the provisions of the law. Finally, in order to achieve the goal of revitalizing the management of Korean heritage information, the study suggests five directions for improvement of the local government ordinance from three perspectives. Firstly, in order to systematize the production of Korean heritage information, it is necessary to specify the entities that produce and manage information in Korean heritage, and to select important Korean heritage information from the information produced and manage it strategically. In today's complex Korean heritage management environment, it is impossible to manage all the Korean heritage information produced by various stakeholders. Secondly, in order to systematize the delivery of Korean heritage information, detailed procedures related to the information to be delivered to the Korean Heritage Service should be specified, and a clear plan for information delivery and management between local and basic local governments should be defined. In the Korean heritage information delivery system, local governments play various roles as direct information providers, managers, consumers, and transmitters. Therefore, it is necessary to specify the provisions of the ordinance so that local governments can systematically fulfill their various roles in the Korean heritage information delivery system. Thirdly, in order to activate the production of Korean heritage information, local governments should review the provisions of the Act to ensure that important Korean heritage information generated from directory provisions and non-mandatory provisions, in addition to the mandatory provisions of the Korean Heritage Act, is not omitted. In particular, Korean heritage information is not just administrative information, but also includes specialized information for the maintenance of the current state of Korean heritage. Therefore, if certain Korean heritage information is partially missing, there may be a gap in intergovernmental communication for Korean heritage management.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • 제23권3호
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • 제27권2호
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • 제28권3호
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.