• Title/Summary/Keyword: 조명계통

Search Result 460, Processing Time 0.019 seconds

Interruption Cost Model of the Feeder Considering the Local Characteristics (지역 특성을 고려한 피더의 정전비용 모델)

  • Hwang, Won-Il;Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.22-28
    • /
    • 2007
  • This paper presents an interruption cost model of the feeder considering the local characteristics. KERI's survey results for the customers interruption cost are used through the research. Interruption cost of the feeder in a city is calculated in the ratio of customer's types. The customers consists of residencial, commercial, industrial and public type. The proposed method is applied to calculate interruption cost of the feeder in a small city and a metropolitan aria.

A Study on the Electromagnetic Transients in A Power System (전력계통의 전자과도현상에 관한 연구)

  • 김경철;강창원;이일무
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

Fiber-Optic Current Sensor Using a Faraday Rotator Glass Fiber Sensor Coil (Faraday Rotator Glass 광섬유 전류센서)

  • 김기혁;송민호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.28-33
    • /
    • 2004
  • We developed a fiber-optic CT for large current monitoring in power systems. We used a FRG fiber sensor coil to suppress CT output degradation caused by linear birefringence, and different optical sources were used to compare their noise characteristics. From the experiments, we obtained output variation less than $\pm$0.4(%) when the sensor coil suffered mechanical perturbations, and the ASE source showed -23(㏈) less noise in the output than singlemode laser diode.

A Study on Filcker Evaluation Considering Power Quality Disturbance of Power System (전력계통의 전력품질 외란을 고려한 플리커 평가에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Lee, Bong-Yi;Cho, Hyun-Kyung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.391-393
    • /
    • 2005
  • This paper studies flicker evaluation considering power quality disturbance. A flicker problem with light device irritates human's eyes. Also, the flicker problem has an influence on adverse effect such as rolling device and rotating device. However, a study of flicker evaluation is not complete. A flicker is measured and evaluated at monitoring point. But we consider power quality disturbances such as voltage sag and transient that cause fault and inverter/breaker switching. Power quality disturbances affects flicker evaluation. A flicker evaluation index increases. Therefore, we consider power quality disturbances. We detect voltage sag and transient using wavelet and evaluate flicker without flicker index including power quality disturbances.

  • PDF

Insulation Characteristic of Moisturized Epoxy Compound (흡습된 에폭시 절연물의 절연 특성)

  • Kim, Dong-Myung;Park, Young-Keun;Kwon, Tae-Ho;Choi, Sun-Gyu;Lee, Byoung-Ho;Choi, Won-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.343-346
    • /
    • 2004
  • 가스절연개폐기의 절연물로 사용되는 에폭시가 흡습환경에 노출될 경우 절연내력은 급격히 저하된다. 에폭시 절연물에 함유되어 있는 수분은 어느 일정 온도에서는 가스 내 수분과 평형을 이루고 있지만 온도변화에 따라 수분은 이동되며 또 고전압 인가 시 절연체 표면은 열화 되어 장기간에 걸쳐 침식과 함께 Treeing 현상을 유발시킨다. 본 연구에서는 에폭시 절연물의 절연특성에 미치는 수분의 영향을 파악하기 위하여 실 계통에서 사용된 제품에 대해 AC 내전압시험 및 재료분석을 시행하였다. 분석결과, 표면의 파괴전압은 주수량에 따라 건조섬락전압의 최대 1/5까지 저하되었다.

  • PDF

Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable (초전도 케이블의 퀜치 특성에 대한 계통안전성 제어방식)

  • Lee, Geun-Joon;Hwang, Si-Dol;Lee, Jeong-Phil;Kim, Chang-Hyun;Park, Hye-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.375-380
    • /
    • 2004
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, and HTS cable could be one of the countermeasure to solve the transfer limit as its higher current capacity and lower impedance[1]. However, the quench characteristic of HTS cable makes HTS cable to loss its superconductivity, and therefore change the impedance of the line and power system operating condition dramatically. This pheonominum threats not only HTS cable safety but also power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method by FCL(Fault Current Limiter) was suggested.

  • PDF

A Study on the Operation of Distribution System for Increasing Grid-Connected Distributed Generation (분산형전원 연계용량 증가를 위한 배전계통 운영방식에 관한 연구)

  • Nam-Koong, Won;Jang, Moon-Jong;Lee, Sung-Woo;Seo, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.83-88
    • /
    • 2014
  • When DG interconnection into network is examined, details of the review are overvoltage, protective device malfunction, etc. In the case of protective device malfunction, replacing protective device into bi-directional protective device and installation NGR are the solution. Overvoltage at interconnection point occurs because the load is relatively less than DG output. When overvoltage at interconnection point occurs, DG interconnection is not permitted because this overvoltage affect other customers. Interconnection by installation new distribution line is one solution but it costs much money. Without installation new investment, change of NOP(Normal Open Point) position is a possible solution about DG interconnection into network.

Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System (교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구)

  • Jeon, Yong-Joo;Kang, Byoung-Wook;Chai, Hui-Seok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

Personnel safety related to a loss of PEN conductor in TN-C-S system (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Bok-Hee;Lee, Kyu-Sun;Joe, Jung-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.59-62
    • /
    • 2009
  • In electrical power supply systems, an earthing system determines the electrical potential of the conductors relative to that of the Earth's conductive surface. The choice of earthing system has implications for the safety of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries. A protective earth(PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth, This paper investigates that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage is caused at personnel body. According to this paper, we can understand that when TN-C-S system is applied in Korea, what we should set up to ensure the personnel safety from fault current.

  • PDF

Performance Evaluation of Protection against Electric Shocks for TT and TN Systems (TT, TN접지계통의 감전보호 성능평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Yoo, Jae-Duk;Shin, Hee-Kyung;Yang, Soon-Man;Kim, Tae-Gi;Lee, Zu-Cheul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF