ICT Convergenced Cascade-type Incubator for mass production of microalgae (미세조류 대량생산을 위한 ICT 융합 계단식 연속 배양 장치)

  • Lee, Geon Woo;Lee, Yong Bok;Yoo, Yong Jin;Baek, Dong Hyun;Kim, Jin Woo;Kim, Ho Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.379-386
    • /
    • 2021
  • This study was undertaken to develop a cascade-type continuous culture system (CCCS) that combines both ICT and biotechnology (BT), for the mass production of microalgae. This system is capable of maintaining the essential culture conditions of pH, temperature, carbon dioxide, and illuminance control, which are key parameters for the growth of microalgae, and is economical for producing microalgae regardless of the season or location. It has the added advantage of providing stable and high productivity. In the current study, this system was applied to culture microalgae for 71 days, with subsequent analysis of the experimental data. The initial O.D. of the culture measured from incubator 1 was 0.006. On the 71st day of culture, the O.D.s obtained were 0.399 (incubator 1), 0.961 (incubator 2), 0.795 (incubator 3), and 0.438 (incubator 4), thereby confirming the establishment of continuous culture. Thus, we present a smart-farm based on ISMC (in-situ monitoring and control) for a mass culture method. We believe that this developed technology is suitable for commercialization, and has the potential to be applied to hydroponics-based cultivation of microalgae and cultivation of high-value-added medicinal plants as well as other plants used in functional foods, cosmetics, and medical materials.

A Study on Estimate for Error and Convergence of Membrane Structures According to the Nonlinear Form-finding Techniques (비선형 형상 탐색 기법에 따른 막구조물의 오차와 수렴성 평가에 관한 연구)

  • Shon, Su-Deok;Kim, Seung-Deog;Jeong, Eul-Seok;Jeon, Jin-Hyung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.57-66
    • /
    • 2007
  • The membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The material property of the membrane has strong axial stiffness, but little bending stiffness. The design procedure of membrane structures are needed to do shape finding, stress-deformation analysis and cutting pattern generation. In shape finding, membrane structures are unstable structures initially. These soft structures need to be introduced initial stresses because of its initial unstable state, and happen large deformation phenomenon. Therefore, in this paper, we investigate the convergence of solution and the speed according to the control variables and the method of shape analysis.

  • PDF

Unscented Transformation According to Scaling Parameter for Motor Drive without Position Sensor (위치 센서 없는 전동기 구동장치를 위한 스케일링 파라미터에 따른 무향 변환)

  • Moon, Cheol;Kwon, Young-Ahn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.174-180
    • /
    • 2016
  • This paper study about an unscented Kalman filter with a variety type of unscented transformation to estimate state values for speed control without position sensor of a permanent-magnet synchronous motor. The principles of an unscented transformation and unscented Kalman filter are examined and their application is explained. Generally the mapping process can be divided into two type, such as a basic and a general form according to a scaling parameter. And computation time, the number of samples, and weights about samples are different from each other. But, there is no little information on the scaling parameter value how this value influences the system performance. Simulation and experimental results show the validity of the designed unscented transformation performance with the various scaling parameter values for sensorless motor drive.

Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers (마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Kim, Gap-Deug;Choi, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • In the present study, to enhance the constructability, a composite slab system using deck plate and micro steel fiber concrete was studied. In the proposed slab system, on-situ re-bar placement is not required. Steel fibers replace the temperature reinforcement. The present study focused on the crack control at the slab top in the continuous composite slab without spliced bars. Eight continuous slabs with various parameters were tested under vertical loading. The test parameters were the amount and types of micro steel fibers, types of deck plate, and the use of top bars in the continuous slab. To evaluate the crack resistance of the slabs, crack widths were measured in the continuous slabs. The test results showed that although the top spliced bars were not used, cracking were restrained by large flexural stiffness of the composite sections.

Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector (수직 오리피스 이젝터의 혼합유동 및 산소전달 특성)

  • Kim, Dong Jun;Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.61-69
    • /
    • 2015
  • The objective of this study is to experimentally investigate the mixed flow behaviors and oxygen transfer characteristics of a vertical orifice ejector. The experimental apparatus consisted of an electric motor-pump, an orifice ejector, a circulation water tank, an air compressor, a high speed camera unit and control or measurement accessories. The mass ratio was calculated using the measured primary flow rate and suction air flow rate with experimental parameters. The visualization images of vertically injected mixed jet issuing from the orifice ejector were qualitatively analyzed. The volumetric oxygen transfer coefficient was calculated using the measured dissolved oxygen concentration. At a constant primary flow rate, the mass ratio and oxygen transfer coefficient increase with the air pressure of compressor. At a constant air pressure of the compressor, the mass ratio decreases and the oxygen transfer coefficient increases as the primary flow rate increases. The residence time and dispersion of fine air bubbles and the penetration of mixed flow were found to be important parameters for the oxygen transfer rate owing to the contact area and time of two phases.

Analysis of Fast Injection Response Characteristics Between Solenoid and Piezo-Driven Injector (솔레노이드 및 피에조 인젝터의 고속분사 응답성 해석)

  • Jo, In-Su;Lee, Jung-Hyup;Lee, Jin-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.971-977
    • /
    • 2012
  • It is well known that the performance of a diesel injector is directly related to the power, emission, and fuel consumption of the diesel combustion engine. In this study, the injection response characteristics of CRDi injectors driven by a solenoid coil and a piezoceramic were investigated by using the AMESim simulation code. Some analytical parameters such as the fuel pressure and hole diameter were considered. From this study, it was shown that the piezo-driven injector had a faster response and had better control capability than the solenoid-driven injector. In addition, it was found that the piezo-driven injector can be utilized more effectively in a multiple injection scheme than a solenoid-driven injector.

Notes on Integrated Disaster Management for Resilient Response to Disaster (지역사회 재난 탄력적 대응 위한 통합 재난안전 관리체계 개선방향에 관한 소고)

  • Shin, Sangmin;Park, Heekyung
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.2
    • /
    • pp.11-20
    • /
    • 2015
  • Integrated disaster management system in Korea is recently concerned due to incompletion and inadequacy in establishment of the system. In this regards, this study aims to examine improvement of the domestic integrated disaster management system considering sustainability and resilience concept, which are recently considered in disaster and safety management. To do this, the authors examined the integrated disaster management system with representative principles to enhance sustainability and resilience in community based on diversity and redundancy, connectivity, slow variable, systematic approach, learning and feedback, and active participation. It is believed that the improvements and recommendations proposed by sustainability and resilience principles in this study can contribute to establishment of strategies, policies, and R&D for enhancing domestic integrated disaster management and sustainability and resilience in community.

Humidification Reduction Study in Proton Exchange Membrane Fuel Cell (고분자전해질형 연료전지의 가습 저감방안 연구)

  • Kim Junbom;Lee Heungjoo;Kwon Juntaek;Kim Kwanghyun;Song Hyundo;Han Jaejin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.239-242
    • /
    • 2005
  • 고분자 전해질형 연료전지에서는 수소이온의 이온전도성 저하를 방지하기 위하여 외부에서 가습하여 주는 방식이 일반적이지만, 가습에 소요되는 부품을 일부라도 제거할 경우 연료전지의 효율은 높이고 제작단가도 경감할 수 있다. 이를 위하여 저가습 및 무가습 실험을 수행하였으며, 정확한 data의 수집과 시험장비의 자동제어를 위하여 National Instrument사의 compact field point (cFP)를 사용하였다. 무가습 실험 중 stack의 안정성 측면을 고려하기 위하여 수소연료가 부족하거나 갑작스런 voltage drop이 발생할 경우 LabVIEW logic에 의한 stack 보호용 자동차단 시스템을 구현하였다. Humidifier와 heater의 온도를 조절하여 공급유체의 상대습도 및 온도를 각각 조절하였으며, 이에 필요한 이론적 온도는 Antoine equation을 사용하여 산정하였다. Anode와 cathode 양측 $100\%$ 가습 경우를 기준으로 가습량을 조절하면서 실험을 수행하였으며 성능 차이를 그래프로 도시하여 양측의 변화에 대한 영향을 볼 수 있도록 하였다. Stack의 온도가 $70^{\circ}C$이고 양측 무가습일 경우에 성능 측정이 불가능하여 stack의 온도를 저온에서부터 변화시키면서 무가습 성능을 실시간으로 측정하여 보았다 일반적으로 hydronium ion은 anode측에서 cathode측으로 계속 이동하여야 전기를 생성할 수 있으므로 cathode측 무가습이 anode측 무가습보다 성능이 더 잘 나오는 것으로 예측하였으나 이와 반대되는 경향의 실험 결과를 얻었다. Anode측 무가습과 cathode측 무가습의 standard deviation은 anode 무가습일 경우가 크게 발생하였고 양측 무가습일 경우는 stack의 온도가 높을수록 크게 관찰되었다. 이와 같은 현상은 공기중의 상대습도와 back diffusion등에 영향을 받을 수 있으므로 각종 변수들의 영향을 분리하여 관찰할 수 있는 실험을 수행중에 있다.

  • PDF

A Study on the Development of Improved Visualization Software of GUI based for Load Flow of Power System (개선된 GUI기반의 전력조류분석용 소프트웨어개발에 관한 연구)

  • 이희영
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.10
    • /
    • pp.611-620
    • /
    • 2003
  • This paper presents improved GUI based analysis tool o( load flow of power system (or contingency. It is effective tool to facilitate the teaching and learning of load flow of power system. This software is the named of PFGUI(Power Flow GUI) that written in TooIBookII of Asymetrix. The PFGUI is friendly for study for power system operation and control because picture provide a better visualizing of relationships between input parameters and effects than a tabula type result. This PFGUI enables topology and the output data of load flow for line outages to be shown on same picture page. Users can input the system data for power flow on the the picture and can easily see the the result diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed PFGUI has been studied on the Ward-Hale 6-Bus system.

  • PDF

A Video Watermarking Method using Global Masking (전역 마스킹을 이용한 비디오 워터마킹 방법)

  • 문지영;호요성
    • Journal of Broadcast Engineering
    • /
    • v.8 no.3
    • /
    • pp.268-277
    • /
    • 2003
  • In this paper, we propose a new video watermarking method exploiting the human visual system (HVS) to find effective locations. in the video frames which make the watermark robust and imperceptible simultaneously. In particular, we propose a new HVS-optimized weighting map for hiding the watermark by considering HVS in three different aspects : frequency, spatial, and motion masking effects. The global masking map is modeled by combining the frequency masking, the spatial masking, and the motion masking. In this paper, we use a watermark which is generated by the bitwise exclusive-OR operation between a logo image and a random sequence. The amount of watermarks is weighted by a control parameter. Furthermore, we embed the watermark in the uncompressed video sequence for the general watermarking method available to various coding schemes. Simulation results show that the watermark is imperceptible and the proposed method is good for watermark capacity. It is also demonstrated that the proposed method is robust against various attacks, such as MPEG coding, MPEG re-encoding, and frame attacks.