• Title/Summary/Keyword: 제곱 회로

Search Result 195, Processing Time 0.02 seconds

The Association Between Working Overtime and Job Performance for Dental Hygienists (치과위생사의 야간진료와 직무성과의 관련성)

  • Mi-Sook Yoon;Young-Eun Kim;Han-A Cho
    • Journal of Korean Dental Hygiene Science
    • /
    • v.7 no.1
    • /
    • pp.39-52
    • /
    • 2024
  • Background: Dental hygienists provide direct dental care in the closest proximity to the patient, and each practice requires a high level of focus and concentration. These skills are an important human resource that can impact the quality of dental care services. Since more than half of dental clinics provide as overtime work in addition to regular hours, this study aims to determine the association between working overtime and job performance for dental hygienists. Methods: The study was conducted using a combination of online and in-person surveys via Google Forms among 131 employed dental hygienists. The survey consisted of 7 questions on demographic and work characteristics, 16 questions on characteristics related to overtime and the effect of overtime on job security, health, and life, and 10 questions on job performance, for a total of 33 questions. Chi-square analysis and independent samples t-test were used to identify the characteristics of demographic and work characteristics, and descriptive statistics analysis was used for the characteristics of overtime. Independent samples t-test was used to test the difference in the mean of job performance according to whether or not they worked overtime, and linear regression analysis was used to show the association of working overtime and job performance. Results: The study found that 71% of dental clinics worked overtime. The average number of overtime per week was once (78.5%), and the most common problems with overtime were fatigue (52.7%) and lack of personal and leisure time (41.9%). The appropriate number of overtime per week considered by dental hygienists was once a week, which was confirmed to be 94.6%. When comparing job performance by overtime status, those who worked overtime were 3.38 points higher than those who did not (35.45 vs. 32.07). Multiple linear regression analysis of the association of working overtime night and job performance showed that a one-unit increase in worked overtime was associated with a statistically significant increase in job performance of about 3.1 (p<0.01). Conclusion: Working overtime was found to have a positive effect on job performance among dental hygienists. Therefore, as a way to improve the working environment, providing appropriate compensation or welfare for overtime can reduce the negative aspects of overtime and turn it into a positive influence on job performance. This could ultimately raise awareness of the dental hygienist as a professional and effect the efficiency of dental care services.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Clinical Analysis of Polymicrobial Bloodstream Infections in Pediatric Patients: Epidemiology, Clinical Features, Organisms, and Risk Factors (소아 환자에서 다균혈증에 대한 임상적 고찰)

  • Kim, Jung Min;Park, Hye Jin;Kim, Ki Hwan;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • Purpose : Although the incidence of polymicrobial bloodstream infection (PBSI) has increased, only a few studies have so far focused on children. Therefore, in an effort to prevent more serious situations in pediatric patients, we analyzed the clinical features, organisms, and laboratory results of PBSI. Methods : We performed a retrospective review of the case records of 97 patients with polymicrobial bloodstream infection in the Severance hospital, from 2001 to 2008. Using t-test and chi-square test, we analyzed the underlying medical conditions, clinical characteristics, organisms, and laboratory results of those patients. Results : Annual incidence of polymicrobial bloodstream infection increased from 1.4 % in 2001 to 10.9% in 2008 in pediatric patients. Immunocompromised hemato-oncological malignancy was found in 31 (31.9%) patients, and was the most common underlying medical condition; cardiovascular disease was found in 15 patients (15.4%), neurologic disease in 10 patients (10.3%), and so on. Gram positive organisms were recovered in 143 cases and gram negative organisms were recovered in 101 cases of PBSI. Staphylococcus epidermidis was the most common organism. Factors affecting mortality included underlying medical disease, immune status, nosocomial infection, and central catheter-related infection, for which the rate of mortality showed a greater increase (P<0.05). Conclusion : Due to the close connection between PBSI and fatal conditions or high mortality, it requires more aggressive management. Compared with previous studies, we discovered that immunocompromised hemato-oncological malignancy was the most common underlying medical condition and that frequency of gram-positive bacteria and fungus isolated has increased.

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Performance Prediction for an Adaptive Optics System Using Two Analysis Methods: Statistical Analysis and Computational Simulation (통계분석 및 전산모사 기법을 이용한 적응광학 시스템 성능 예측)

  • Han, Seok Gi;Joo, Ji Yong;Lee, Jun Ho;Park, Sang Yeong;Kim, Young Soo;Jung, Yong Suk;Jung, Do Hwan;Huh, Joon;Lee, Kihun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • Adaptive optics (AO) systems compensate for atmospheric disturbance, especially phase distortion, by introducing counter-wavefront deformation calculated from real-time wavefront sensing or prediction. Because AO system implementations are time-consuming and costly, it is highly desirable to estimate the system's performance during the development of the AO system or its parts. Among several techniques, we mostly apply statistical analysis, computational simulation, and optical-bench tests. Statistical analysis estimates performance based on the sum of performance variances due to all design parameters, but ignores any correlation between them. Computational simulation models every part of an adaptive optics system, including atmospheric disturbance and a closed loop between wavefront sensor and deformable mirror, as close as possible to reality, but there are still some differences between simulation models and reality. The optical-bench test implements an almost identical AO system on an optical bench, to confirm the predictions of the previous methods. We are currently developing an AO system for a 1.6-m ground telescope using a deformable mirror that was recently developed in South Korea. This paper reports the results of the statistical analysis and computer simulation for the system's design and confirmation. For the analysis, we apply the Strehl ratio as the performance criterion, and the median seeing conditions at the Bohyun observatory in Korea. The statistical analysis predicts a Strehl ratio of 0.31. The simulation method similarly reports a slightly larger value of 0.32. During the study, the simulation method exhibits run-to-run variation due to the random nature of atmospheric disturbance, which converges when the simulation time is longer than 0.9 seconds, i.e., approximately 240 times the critical time constant of the applied atmospheric disturbance.