• Title/Summary/Keyword: 전원제어장치

Search Result 600, Processing Time 0.028 seconds

A Study on the Grid Connected Battery Charge System (삼상 계통연계형 배터리 급속충전시스템에 관한 연구)

  • Lee, Young Jin;Han, DH;Ban, CH;Kim, Yeong-U;Seong, Baek-Seo;Eun, JM;Choe, Gyu Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.367-368
    • /
    • 2010
  • 본 논문에서는 삼상 AC-DC 컨버터와 강압컨버터를 이용한 배터리 충전장치를 제안한다. 제안 하는 배터리 충전시스템은 상용전원뿐만 아니라 태양광시스템의 MPPT제어를 통하여 최대전력을 공급받아 급속충전시스템의 CV/CC(정전압/정전류) 모드 제어를 통해 배터리를 빠르게 충전한다.

  • PDF

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.

Implementation of Remote Control System using TeleRemote System (TeleRemote를 이용한 원격 제어 시스템 구현)

  • 김상복;한성호;진현준;박노경
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12B
    • /
    • pp.1115-1123
    • /
    • 2003
  • In this paper, a remote control system called TeleRemote system which can be applied to existing wireless mobile networks or public telephone networks for remote control is designed and implemented. The proposed design employs program technology based on the theory of signal detect control and enables the EPG(Electronic Program Guide) functions such as recording reservation of bidirectional video signals with TV reception card on PC. It can also control recording reservation using remote control program through telecommunication network The PC-EPG system is implemented in Web programs with Server/Clinet architecture and the server system that provides EPG functionalities is in charge of recording reservations and data communications by means of the scheduler program. Data storing to client PCs is performed through TCP/IP and finished by client programs implemented using Visual C++/MFC programs. As remote control system, the developed system can be used for unmanned security system using the Web camera. Building intranet and making connection to internet, the TeleRemote system is believed to create potential for commercial communication system.

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.

Improvement of Naval Combat System UPS under Abnormal Transients (비정상 과도상태에서의 해군 전투체계 UPS 개선)

  • Kim, Sung-Who;Choi, Han-Go
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.97-103
    • /
    • 2018
  • This paper addresses an improved naval combat UPS(Uninterruptable Power Supply) system under abnormal transients. Previously, thermistor and varistor elements were used to cope with transient overvoltage and overcurrent, however the UPS was frequently unavailable because it was vulnerable to abnormal transient voltage generated during system operation. In order to overcome this problem and protect UPS system, this paper proposes an input power cut-off circuit that detects the initial input power and abnormal transient voltage generated during operation, improvement of power control sequence, and a method to prevent malfunction of an inverter and CPU. The UPS system implementing the proposed method was simulated by input power variable test using programmable AC/DC generator, and finally validated its reliability and stability through field tests by mounting on multifunctional console of naval combat system.

Photovoltaic Generation System Control Using Space Vector PWM Method (공간벡터 PWM 방식을 이용한 태양광 발전 시스템 제어)

  • Cho, Moon-Taek;Choi, Hae-Gill;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.31-37
    • /
    • 2010
  • In this paper, a photovoltaic system is designed with PWM(Pulse Width Modulation) voltage source inverter. Proposed synchronous signal and control signal was processed by 56F8323 microprocessor for stable modulation. The PWM voltage source inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power, from 10 to 20[%]. The PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In addition, I connected extra power to the system through operation the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and PWM voltage inverter can be synchronized. In the system of this research showed good results after being controlled in order to provide stable power to the load and the system through maintaining and low output power of harmonics.

Steady-State Performance Improvement of Single-Phase PWM Inverters Using PLL Technique (PLL 기법을 이용한 단상 PWM 인버터의 정상상태 성능개선)

  • 정세교;이대식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.356-363
    • /
    • 2004
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control scheme employs an additional phase-locked loop(PLL) compensator which is constructed using the output capacitor voltage and current. The computer simulation and experiment are carried out for the actual single-phase PWM inverter and it is well demonstrated from these results that the steady-state performance and total harmonic distortion(THD) are remarkably improved by employing the proposed technique.

A Study on the Minimization of Power Dissipation in Control Element of the Series D.C. Voltage Regulator (직류안정전화원의 제어소자에 전력소모의 최소화에 관한 연구)

  • Choe, Byeong-Ha;Lee, Gyun-Ha;Choe, Hui-Tae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.5
    • /
    • pp.12-18
    • /
    • 1975
  • Triac phase controlled pre-regulator를 이용한 직류안정화전원에서 제어소자 전력소모를 촤소로 줄이기 위하여, 부하전류의 증가에 따라 제어소자 양단전압을 낮추어 주는 회로를 고안하여 부가하였다. 이렇게 하므로써 제어소자의 전력소모가 약 40%정도 감소되어 방열장치가 간단해지거나 전력용량을 증가할 수 있게 되었으며 열발산이 곤란한 monolithic I.C.화에 유용하도록 하였다. A method on minimizing the power dissipation in the control element of a series D.C. voltage regutator is devised. An additional control circuit which reduces the average voltage drop across the control element according to increasing the load current is attached :o the trial phase controlled pre-regulator system. It is verified that the power dissipation in the control element is reduced up to 40% by this. circuit arrangement. The heat sink system can be simplified and the capacity of tile handling power is also increased. It is expected that this circuit arrangement can be applied to I.C. fabrication.

  • PDF

Construction and Tests of the 0.4 MW Class Enhanced Huels Type Plasma System

  • Kim, Min-Ho;Lee, Mi-Yeon;Choe, Chae-Hong;Kim, Jeong-Su;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.150-150
    • /
    • 2012
  • 본 연구에서 개발된 Enhanced huels형 플라즈마 발생장치는 초음속 공기 플라즈마 환경에 대한 열 보호 물질의 개발과 시험평가를 위한 지상 시뮬레이션 시험을 목적으로 개발되었다. Enhanced Huel형 플라즈마 토치는 고출력에도 불구하고 전극 부식에 의한 오염도를 최소화할 수 있고, 일반적인 직류 토치로는 얻을 수 없는 초고엔탈피 플라즈마 열유동을 얻을 수 있는 특징이 있다. 구축된 장치는 최대 직류 전력 1,200 kW까지의 출력 제공이 가능한 DC 전원과 플라즈마 토치, 플라즈마의 진단계측 및 재료 시험 수행이 가능한 진공쳄버, 플라즈마를 기체로 회복시켜주기 위한 디퓨저, 디퓨저를 빠져나오는 초고온 열 유동으로부터 열을 제거하기 위한 열교환기, 쳄버 전체의 압력을 제어하기 위한 진공 장치, 후처리 시스템, 가스 공급부 시스템, 냉각수 공급 시스템으로 구성되어 있다. 또한 플라즈마 진단계측장비로는 enthalphy 측정시스템과 각 종 열유속 측정 탐침기, pyrometers, 분광계, 적외선 카메라, 고속 카메라를 갖추고 있다. 시운전 결과 토치 공급전력 412 kW, 공기공급 12.31 g/s , 토치 내부압력 4.14 bar의 운전조건에서 62%의 효율로 플라즈마 엔탈피 16.7 MJ/kg의 성능을 얻었다.

  • PDF