• Title/Summary/Keyword: 전면검사

Search Result 89, Processing Time 0.02 seconds

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Long-term Effect of Campus Smoking Cessation Program for College Students (대학생을 위한 캠퍼스 금연교육 프로그램의 장기 효과에 관한 연구)

  • Lee, Eunhye
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.442-451
    • /
    • 2019
  • This study was conducted to investigate the long-term smoking effect of college students who participated in the campus smoking cessation education program and succeeded in quitting. The participants were 30 of the successful smokers who quit smoking after participating in a 36-week and 2nd data from the resulf of the campus smoking cessation program at a university in Seoul from 2016 to 2018. The smoking cessation education program of a university in Seoul, which is completely prohibited from smoking on campus, consisted of smoking cessation education and counseling, once-weekly urine cotinine test, and cessation scholarships. After successful quitting in this study, 51.22% of the participants had quit smoking for more than 12 months, and 48.78% of the respondents included non-smokers. The biggest success factor in quitting smoking was the willingness to quit smoking, and the biggest failure in quitting smoking was stress. The campus-led smoking cessation education program for college students was found to be an effective program for converting into a long-term non-smoking maintainer by habitually quitting smoking.

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Scintigraphic Findings of Fibrous Dysplasia (섬유성 골 이형성증의 골 신티그라피 소견)

  • Kim, Jong-Ho;Kim, Jong-Soon;Han, Seung-Soo;Kim, Sang-Eun;Choi, Chang-Woon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kang, Heung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.219-226
    • /
    • 1991
  • 골 신티 그라피는 섬유성 골 이형성증의 초기 병소와 다골성 형 섬유성 골 이형성증의 진단에 예민한 검사 방법이나, 양성 또는 악성 골 병변과의 감별진단에 어려움이 있었다. 이에 저자들은 조직학적으로 확진된 섬유성 골 이형성증 환자 17명에서 (단골성 형 12명, 다골성 형 : 5명) $^{99m}Tc-MDP$ (20 mCi 또는 7,400 MBq) 주사후 $2\sim4$시간에 전면, 후면 전신상과 부분상을 얻은 30부위 병소를 X선 사진과 비교분석 하였으며 CT, MRI 영상과 병리조직 소견을 얻었다. 병소 침습 부위별로는 대퇴골-10예, 경골-4, 요골-2, 늑골-2, 척추골-2, 후두골-2, 장골-2, 두정골-1, 하악골-1, 접형골-1, 견갑골-1, 쇄골-1, 척골-1예 였으며 5명의 다골성 형에서는 :우 대퇴골과 우 비골 : 양측 말단 대퇴골 :좌 경골과 좌 대퇴골 :우 요골과 우 장골 양측 대퇴골, 양측 경골, 접형골, 두정골, 척추골, 늑골과 장골이었다. 골 신티 그라피 소견상 30예중 28예에서(28/30, 93.3%) 방사능 섭취 증가를 보였으며 2예에서(2/30, 6.7%)는 정상 방사능 섭취 소견을 보였으나 각각은 X선상 불투명 유리상과 골흡수 병변을 보였다. 하악골의 골 3상 스캔상 병소에 현저한 혈류 증가가 관찰되었다. X선 소견상 30예중 11예에서 (l1/30, 36.7%) 불투명 유리상의 병변을, 골 변형을 동반한 1예를 포함한 18예에서는 (18/30, 60.0%) 골흡수 병변을 보였으며, 1예의 늑골 병변은 정상소견을 보였다(1/30, 3.3%). 이상에서 골 신티 그라피 만으로 섬유성 골 이형성증을 진단하는데는 주의를 요하나 골 대사의 동적 측면인 혈류와 골 재형성 양상 특히, 초기 병변과 단골성 형 침습에서 다골성 형을 진단하는데 필수적이며 결론적으로 골 신티 그라피와 X선 촬영등은 섬유성 골 이형성증 진단에 상호보완적인 검사 방법으로 사료된다.

  • PDF

Management Policy and Safety Problem of School Food Services (학교급식 안전 문제와 대책)

  • Ha, Sang-Do
    • Safe Food
    • /
    • v.3 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • 우리나라 학교급식의 현재 성적표를 "양적 성공, 질적 실패"로 평가할 수 있다. 2003년 학교급식이 국가적 교육사업이 되어서 초 중 고 특수학교에서 전면급식이 이루어지고 10,343개교에서 704만명의 학생에게 급식을 제공하고 있다. 현재는 양질의 학교급식을 안전하고 저렴하게 공급하고, 국가식량정책과 연계하여 효율적으로 관리하여야 할 시기이다. 그러나 학교급식 소요경비 연 2조3천억원, 영양사 7,196명 등 63,145명이 종사하는 거대한 산업군이라는 규모에도 불구하고 전체 학교의 70%만이 식당시설을 갖추고 있고 급식 만족도가 학생이나 학부모의 기대에 미치지 못하고 있으며, 식중독 발생의 원흉이 되어 국민적 질책의 대상이 되고 있는 것이 현실이다. 이 문제는 1) 영양사 업무과중에 따른 시간부족, 영양사 지식정보 부족 등에 따른 식재료 및 위생관리 소홀, 2) 냉장, 냉동, 오염/비 오염 구획 등에 필요한 시설과 설비 부족, 3) 교육인적자원부의 급식위생관리의 전문성 부족과 담당 인력 및 정책적, 재정적 지원 부족을 원인으로 볼 수 있다. 학교급식 안전대책은 아래 20대 과제를 추진하여 확보하여야 할 것이다. 전략 1은 "우수한 식재료 위생관리"로서 "급식비 인상 및 현실화, 철저한 수입 농수축산물관리, 식재료 공급 및 전처리업 자유업에서 신고제, 허가제로 전환, GAP(우수농산물관리) 제도 도입, 생산이력제도(traceability) 도입, 급식원료 "품질인증 제도" 도입, 식품원료 전처리 시 세척, 소독프로그램 보급, 학교급식 식자재기준, 규격 설정, 과학적이고 쉬운 검수지침 개발 및 보급, 신속검사키트를 활용한 주기적인 미생물 검사 의무화, 위생 전문가에 의한 검수, 식재료별로 분산된 법령과 관리제도 정비(식품안전기본법), 급식식자재 공급 유통 과정의 감시 감독 강화" 등 13개 과제를 제안한다. 전략 2는 "급식위생 확보 인프라구측"으로서 "급식종사자 전문성 확보(조리/영양/위생), 급식전담기구(학교급식진흥원 /학교급식센터 등) 설치, 급식형태 다양화(위탁/직영 균형 발전), 학교급식법 재개정, 학교급식 HACCF제도 확대" 등 4개 과제를 제안한다. 전략 3은 "급식소 시설 설비 현대화 및 환경개선"으로서 "급식시설 설비 현대화 (전처리실, 냉장고, 온장고 구비 등), 급식소 환경 개선 (상수 사용 확대 및 안전강화, 지하수 소독 강화, 정화된 공기 공급 등)" 등 2개 과제를 제안한다. 전략4는 "급식위생제도 및 관리체계 개선"으로서 "전문적 단일기관 안전관리 (식품안전처)" 과제를 제안한다.

  • PDF

Development of Coordinate Transformation Tool for Existing Digital Map (수치지도 좌표계 변환 도구 개발)

  • 윤홍식;조재명;송동섭;김명호;조흥묵
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • This study describes the development of coordinate transformation tool for transforming the digital map using newly derived transformation parameters which are determined from the data referred to the local geodetic datum and the geocentric datum (ITRF2000) and the distortion modelling derived from collocation method. We prepared 190 common points and used 107 points to calculate 7 transformation parameters. In order to evaluate an accuracy of coordinate transformation, 83 common points were tested. In this study, we used Molodensky-Badekas model to derive the 7 transformation Parameters. An accuracy of 0.22m was obtained applying 7 Parameters transformation and the distortion modelling together. It shows that the accuracy of coordinate transformation is improved 72% against the result of 7 parameters transformation only. We developed the transformation tool, GDKtrans, which can be transformed the digital map of scales 1/50,000, 1/25,000 and 1/5,000. We also analyzed the digital map of l/5,000 at six urban areas by GPS observations. The result shows less RMSE of about 1.9 m and large disagreement at position and features. Consequently, we suggests that l/5,000 digital map is necessary of whole revision.

A Case of Esophageal Perforation and Mediastinitis complicated after Foreign Body Ingestion (식도천공 및 종격동염을 초래한 식도이물 1례)

  • 김무명;나기상;김광현;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.8.5-9
    • /
    • 1981
  • Foreign body in the esophagus is not uncommon in the otolaryngological field and esophageal perforation followed by mediastinitis is one of the most serious complications. Authors had experienced such case developed in 69 year old female patient. This woman swallowed a piece of sharp glass accidentally. Severe pain and swelling around the neck developed after ingestion. Marked subcutaneous emphysema was noted on first examination. By esophagoscopy, longitudinal laceration at right lateral wall of the cervical esophagus was noted and a lot of food debries were removed through this perforation, but foreign body could not be found. On third hospital day, patient complained chest pain and dyspnea. Mediastinal widening was noted on chest P-A. Tracheostomy was performed on next day and neck swelling decreased much. In spite of massive antibiotics, mediastinal abscess was developed and external drainage was performed on 15th hospital day. She was discharged on 38th hospital day with marked improvement and recovered completely on follow-up study. Still, we do not know where the foreign body is located.

  • PDF

Studies on the Production of Vinegar from Barley (보리 식초(食酢) 제조(製造)에 관(關)한 연구(硏究))

  • Kim, Hai-Jung;Park, Sae-Ho;Park, Chang-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.350-354
    • /
    • 1985
  • For the purpose of studying the possibility to use the barley as a raw material in vinegar manufacturing process, several factors related to the fermentation of acetic acid were investigated. The optimum quantity of sweet liquor prepared by koji method in medium was 30-40%. When koji of A. oryzae, commercial enzyme products and malt were used for the saccharification of the barley, the production rates of acetic acid during log period were 0.056%/hr, 0.025%/hr, 0.03896/hr and lag period were 22 hours, 48.5 hours and 25 hours, respectively. These results indicate that the saccharifying method using koji of A. oryzae is superior to that by the commercial enzyme products or malt for the acetic acid fementation. The optimum initial acidity was 2% and the proper initial ethanol degree were 4-6% in metium. In a submerged culture process using a jar fermentor, lag period was 15 hours, and acetic acid fermetation period was about 45 hours. In the sensory test of barley vinegar and commercial vinegar of the market, barley vinegar was superior to the vinegar in market with respect to tastes.

  • PDF