• Title/Summary/Keyword: 전류분포

Search Result 710, Processing Time 0.024 seconds

Improvement of the Pumping Force in the Magnetic Fluid Linear Pump by AC Pulse current (AC Pulse에 의한 Magnetic Fluid Linear Pump의 펌핑력 향상에 관한 연구)

  • SEO Kang;PARK Gwan soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.986-988
    • /
    • 2004
  • 이 전에 DC Pulse 전류로 구동하는 Magnetic Fluid Linear Pump(MFLP)를 개발하였다. 개발된 MFLP는 DC Pulse 전류에 의하여 발생하는 자기장의 분포 변화가 불연속적이게 되고, 펌핑력 또한 불연속성을 가지게 된다. 불연속적 자기장의 변화와 펌핑력의 불균일성을 저감하였다. 펌핑력을 증가시키기 위하여 AC 전류를 이용하였으며, 이에 따른 펌프의 운전 특성을 파악하기 위하여 자기장의 분포와 자성유체의 형상을 해석하였다.

  • PDF

heat distribution of photovoltaic module with current (전류에 따른 태양전지 모듈의 열 분포)

  • Kim, Tae-Bum;Jung, Tae-Hee;Shin, Jun-Oh;Won, Chang-Sub;Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Han, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.469-470
    • /
    • 2009
  • 본 논문은 전류의 변화에 따른 태양전지 모듈의 열 분포에 대하여 실험하였다. 태양전지 모듈의 경우 내구성의 문제가 대두되고 있는데 그 중에 열에 의한 노화현상이 가장 큰 문제이다. 실제적으로 태양전지 모듈에서 저 전류와 고 전류의 경우에서 서로 상이한 열 분포가 이루어지고 있다. 이번 연구를 통해 열 해석에 있어서 전류에 따른 태양전지 모듈에서의 열에 의한 노화현상을 좀 더 정확히 예측 할 수 있을 것이다.

  • PDF

직류 전류 이용 종양세포의 효율적 치료에 관한 시뮬레이션 연구

  • Kim, Jae-Hong;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.289-289
    • /
    • 2010
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 암세포가 사멸되는 임계온도 보다 높게 악성조직에 열을 가하는 방법이 연구되어지고 있다 [1]. 전류가 흐를 수 있는 4개의 전기탐침을 종양조직에 삽입하여 국부적으로 열을 발생시키는 발열요법으로 암을 치료하는 연구가 고려되고 있다. 발열요법은 1960년대에 시작하여 우리나라에서는 1985년 연세 암센터에서 capacitive type의 RF heating 또는 전자파에 의한 국소가온법과 방사선치료와 병용으로 이용되고 있다. 주로 이용되는 방법은 Radio frequency heating, Microwave heating, ultrasound heating을 들수 있다. 라디오주파수는 보통 300 MHz 이하의 주파수를 가리킨다. 본 연구에서는 교류파 대신에 직류전원에 의해 열을 발생하는 경우에 관한 연구이다. 전극에 의해 형성되는 전기장에 대한 방정식은 전도매질에서의 DC 응용모드이고, 조직 내에서의 직류 전류에 의해 발생되는 온도 분포를 모델링하는 bioheat 방정식과 연계된 문제이다. 전기장에 의해 발생되는 열의 근원은 resistive heat 또는 Joule 열이다. 본 연구에서는 교류 전류에 의한 RF heating 대신 단순한 모델의 경우로 직류 전류에 의한 열 발생에 관한 이론적 연구를 수행하였다. 종양 조직 내에 삽입된 전극에 22V를 인가하면 60초 이내에 $80^{\circ}C$까지 급속히 증가 된 후, 서서히 $90^{\circ}C$에 까지 도달한다. 4 개의 전극에 대칭적인 전위가 인가 된 경우 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하게 하여 효과적인 치료를 수행 할 수 있는 조건을 제시한다.

  • PDF

A Simulation study on the Cardiac Current Density distribution during the Defibrillation Shock (제세동 쇼크에 의한 심장 전류밀도 분포에 관한 시뮬레이션 연구)

  • Lee, J.;Park, K. L.;Lee, K. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.403-409
    • /
    • 2000
  • This paper is about to simulate the defibrillation situations using 3D FE(finite element) thorax model and describes the effects of three clinical electrodes' positions and size and organ's resistivity used in simulation on the characteristics of current density distribution over myocardium. The model was constructed with a eillipsoidal cylinder for the thorax and the 2D Visible Human images for remains. And, the distributions of current density were computed by a commercial program ANSYS 5.4. The electrical shock of the AP(anterior-posterior ) electrode provided more current flows with heart than the others and that of the LL(lateral-lateral) electrode showed the most uniform current density distribution. However, the electrode size had little effect on the current density distribution. In the evaluation of model's sensitivity to tissue resistivity variation, the variation of the myocardium's resistivity most affected the minimum, average and maximum current densities.

  • PDF

Current Distribution on a Six Points Fed Linear Antenna (육점급전안테나의 전류분포)

  • 박정기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.3
    • /
    • pp.12-23
    • /
    • 1969
  • In this paper, the current distribution on a 6 points fed linear antenna is theoretically introduced. The antenna that we call the 6 points fed linear antenna is an antenna which are fed by emf E1 at the first two points, emf E2 at the second two points, and emf E3 at the third two points. symmetrical with respect to the center. In this analysis, Hallens theory has been extended with the approximation in the same order.

  • PDF

Selection of Capacity of Circuit Breaker by Probabilistic Short-Circuit Current Analysis (확률적 고장전류 해석에 의한 차단기 용량 선정)

  • 문영현;오용택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.10-15
    • /
    • 1990
  • This paper presents an algorithm that can compute equivalent impedance effctively in computing 3-phase short circuit current which would be generated in power systems. Also this paper proposes a method that can decide the capacity of circuit breaker by analysing the fault current distribution probabilistically when the fault point of specificed line varies. The efficiency of the algorithm was verified by applying the proposed method to IEEE-6bus system and IEEE-30bus system, and probabilistic fault analysing method is verified economic in facility investment by deciding the proper capacity of circuit breaker.

  • PDF

Analysis of Subthreshold Current Deviation for Channel Dimension of Double Gate MOSFET (이중게이트 MOSFET의 채널크기 변화 따른 문턱전압이하 전류 변화 분석)

  • Jung, Hakkee;Jeong, Dongsoo;Lee, Jongin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.753-756
    • /
    • 2013
  • This paper analyzed the change of subthreshold current for channel dimension of double gate(DG) MOSFET. The nano-structured DGMOSFET to reduce the short channel effect had to be preciously analyze. Poisson's equation had been used to analyze the potential distribution in channel, and Gaussian function had been used as carrier distribution. The subthreshold current had been analyzed for device parameters such as channel dimension, and projected range and standard projected deviation of Gaussian function. Since this potential model was verified in the previous papers, we used this model to analyze the subthreshold current. Resultly, we know the subthreshold current was influenced on parameters of Gaussian function and channel dimension for DGMOSFET.

  • PDF