• 제목/요약/키워드: 전기통신시스템

검색결과 1,740건 처리시간 0.036초

전력통신시스템 신뢰도 평가모델 구성 연구 (A study on the OAM evaluation model for power telecommunications system)

  • 이원태;이재조;김관호;오면택;이복규;이원빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1330-1332
    • /
    • 1996
  • Power telecommunication networks is being increased rapidly in that expansion of power plant according to the growth of electric power supply. The requirement of power plant operation & office automation make it to complex and confusing to operate. So, for the sake of correspond to the change, it is necessary that telecommunication network should be high reliable and managed effectively. In this paper, we suggest total reliability evaluation models for power telecommunication network which is based on the QOS(quality of service) standardization techniques recommanded by ITU-T.

  • PDF

RF통신과 에너지 변환 기술을 이용한 RF-ID시스템 (RF-ID System using RF Communication and Energy Transformation Technic)

  • 임상욱;김용상;이교성;이용제;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1306-1308
    • /
    • 2003
  • RF-ID technic will got over not only damage which can be caused by contact ID technic but also worse awareness with the lapse of time. In advance, for subway the fares of mass transportation at rush hours of the days, it's important to find a way to collect fares without unnecessarily delaying passengers. In this paper. we are proposing RF-ID system using the RF Communication Technic and Energy Transformation Technic.

  • PDF

통신기반 열차제어시스템에서의 다편성 열차간격제어를 위한 알고리즘 개발 (The Development of Automatic Multi Train Spacing Algorithm Using Communication)

  • 백종현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1309-1311
    • /
    • 2003
  • Communication based train control system is applied regularly worldwide. And this system may be used in domestic soon. Communication based train control system does not depend on conventional track circuit. Therefore, position and distance control of train to prevent collision with loading train may become important safety factor. This paper developed collision avoidance algorithm to control trains of several units efficiently for this. In developing a collision avoidance algorithm, it is desirable to avoid the need for additional system. Additional system restricts the development of the algorithm by limiting the effectiveness of the algorithm to only those areas where the additional system can be afforded and has been installed.

  • PDF

전동차 통신시스템 성능평가를 위한 시뮬레이터 개발 (A Simulator for the Performance Evaluation of the Train Communication Network(TGN))

  • 이수길;한성호;구동회;모창우;최성훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1329-1331
    • /
    • 2003
  • This paper presents a Train Communication Network simulator (TCNS) that can be used to evaluate the performance of TCN. TCN was accepted as the standard of the protocol for the communication network in trains. We carry out some simulation tests using the TCNS to show practical uses of the simulator. Results of some simulation tests are also reported.

  • PDF

통신교환기용 DC 전원시스템을 위한 에너지 절약형 지능제어기 (Intelligent Energy Saving Power System Controller for Telecom DC Power Plant)

  • 김일중;구세완;김택용;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.323-325
    • /
    • 1996
  • The design of Intelligent Energy Saving Power System Controller (IESPSC) for Telecom DC power plants is proposed and presented in this paper. From the past experience. rectifiers for Telecom DC power plants have been operated inefficiently at light loads. IESPSC offers "novel load sharing" approach based on the knowledge of each unit's efficiency of paralleled rectifiers. Neural networks is used for identifying each rectifier's efficiency characteristic curve corresponding to load currents, which is in turn utilized to produce a system efficiency close to the maximum under all operating conditions. In addition, by limiting the number of operating units to the minimum while maintaining high efficiency at the determined loads, a drastic savings in operating cost can be achieved.

  • PDF

CAN 통신을 기반으로한 전력 시스템 자동화 구축 (The Development of Power System Automation based on the CAN Communication Protocol)

  • 박종찬;김병진
    • 전기학회논문지P
    • /
    • 제52권3호
    • /
    • pp.95-99
    • /
    • 2003
  • In this paper, the power system automation based on CAN communication protocol is introduced. Along with digitalization of electrical device, the various on-line services such as remote control, remote monitoring, remote parameter setting, fault data recording and remote diagnostic have been realized and become available. Therefore, it is necessary for those electrical devices to have real-time and reliable communication protocols. Author proposes DNPC(Distributed Network Protocol with CAN) which is proper to the power system SCADA (Supervisory Control And Data Acquisition) and DCS (Distributed Control System). The physical and datalink layer of DNPC protocol consists of the CAN2.0B which has the real-time characteristics and powerful error control scheme. As the transport and application layer, DNP3.0 is adopted because of its flexibility and compatible feature. Using the DNPC protocol, the power system automation is realized.

열차제어 통신시스템의 안전성 평가를 위한 연구 (Study on Safety Assessment for Train Control Communication Systems)

  • 조현정;황종규;정락교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.186-188
    • /
    • 2009
  • Safety-critical systems related to the railway communications are currently undergoing changes. Mechanical and electro-mechanical devices are being replaced by programmable electronics that are often controlled remotely via communication networks. Therefore designers and operators now not only have to contend with component failures and user errors, but also with the possibility that malicious entities are seeking to disrupt the services provided by theirs systems. This paper discusses the safety strategies employed in the railway communications and proposes a security mechanism for Korean railway communication system.

  • PDF

IEC 61850의 GOOSE와 관련된 TISSUES 조사 (TISSUES Survey regarding the GOOSE in IEC 61850)

  • 송운식;장혁수;양효식;김용원;김상식;박민우;장병태;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.509-510
    • /
    • 2007
  • IEC 61850은 변전소 자동화 시스템에 관한 국제표준문서이다. IEC 61850의 특징의 중의 하나로서 GOOSE가 있다. GOOSE는 변전소기기 간에 빠르고 신뢰성을 보장하여 기기들 간의 정보교환을 위한 IEC 61850 통신 서비스이다. IED는 GOOSE 메시지를 통해 트립 신호와 같은 중요한 정보를 전송한다. 현재 몇몇의 IEC 651850 기반의 기기들이 개발되었고, 한국에서는 IEC 61850 기반의 IED를 개발하고 있다. IEC 61850 표준문서에서 오류, 모호한 점 그리고 추가할 점들이 발견되고 있다. 이러한 문제들은 Technical Issues라 부른다. 이 논문은 IED 개발업자 또는 검사자에게 IEC 61850과 관련된 좀 더 나은 이해와 견해를 제공하기 위하여 GOOSE에 관한 기술적 이슈를 조사한다.

  • PDF

전력선 통신을 위한 저압 배전 시스템의 임피던스 연구 (Study on Characteristic Impedance in LV Distribution System for PLC)

  • 김용성;김재철;이양진;조성민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2006
  • In this paper, the investigation of characteristic impedance on low voltage distribution system is described The residential area of LV distribution systems is researched for the modeling. At frequency range from 1MHz to 30Mhz, the input characteristic impedances of low-voltage distribution network are obtained with experiments. The low-voltage distribution system based on the model is built at the laboratory building. S parameters are measured by performing experiments. Finally, the characteristic impedances are reported.

  • PDF

RF 무선통신 기술을 이용한 심전도 및 온.습도 측정 시스템 (The Measurement System of ECG, Temperature and Humidity Using RF wireless Communication Technique)

  • 임진희;남효덕;정우철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.356-357
    • /
    • 2007
  • In this paper, we developed an integrated miniaturized device which acquires and transmits the signal of ECG an interested heartbeat and body's temperature and humidity. Using an amplifier circuit on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system. The sensor signals are transmitted to the RF-wireless terminal that was developed using the micro controller Aduc812, LCD, RF-module (frequency 424MHz, 9600-bps). In results, the developed system improves not only the signal-to-noise ration in dynamic ECG & and body's temperature and humidity measurement, but also the user convenience.

  • PDF