• Title/Summary/Keyword: 전기임피던스

Search Result 1,221, Processing Time 0.031 seconds

Design of Housing Structure for the Suppression of Higher­Order Modes in the Microstrip Circuit Packaging (마이크로스트립 회로 패키징의 고차모드 차폐를 위한 하우징 설계)

  • 전중창
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1621-1628
    • /
    • 2003
  • Packaging structures to block the propagation of higher­order modes in the shielded microstrip lines are designed. Packaging for microwave circuits is necessary, basically, to isolate and protect circuits from outside environments both physically and electrically. The drawback of packaging is the possibility of higher­order mode propagation, similar to waveguide modes, as the operating frequency increases. One of Possible choices for the higher­order mode suppression is to insert diaphragms to the housing structure. The shielding effects of diaphragms are analyzed using an FEM code. Several parameters such as dispersion, mode conversion, and higher­order mode transmission and reflection are analyzed. The effect of higher­order mode suppression is eminent as the depth or width of a diaphragm is increased in the air region of the microstrip line. It is shown that inductive diaphragm structure can lower ${S_21}$ for the second­order mode incidence by 30㏈, comparing with the conventional capacitive diaphragm structure. Packaging structure analyzed in this paper can be applied usefully to the design of the microwave system in a package such as transmit/receive modules.

Piezoelectric Polymer Ultrasound Transducers and Its Biomedical Applications (압전고분자 초음파 트랜스듀서와 생의학적 응용)

  • Ha, Kang-Lyeol;Cao, Yonggang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.585-596
    • /
    • 2012
  • PVDF(poly vinylidene fluoride) and P(VDF-TrFE)(poly vinylidene fluoride-tetrafluoroethylene) are the typical piezoelectric polymers with unique properties. Even they are inferior to conventional piezoelectric ceramics PZT in electromechanical conversion efficiency and interior loss, though they are superior in receiving sensitivity and frequency bandwidth. Their acoustic impedances are relatively close to water or biological tissue and it is easier to make thin film than other piezoelectric materials. Futhermore, the film is so flexible that it is easy to attach on a complex surface. Those properties are suitable for the ultrasound transducers which are useful for medical and biological application, so that various types of polymer transducers have been developed. In this paper, several important considerations for design and fabrication of piezoelectric polymer transducers were described and their effect on the transducer performance were demonstrated through the KLM model analysis. Then, it was briefly reviewed about the structures of the polymer transducers developed for obtaining images as well as the characteristics of the images in several important medical and biological application fields.

A Study on the Weighing scales Design for Electrical Activity Monitoring of the Heart (심장의 전기활동 측정이 가능한 체중계 설계에 관한 연구)

  • Lee, Kang-Hwi;Kang, Seung-Jin;Kim, Kyung-Nam;Min, Se-Dong;Choi, Dong-Hak;Lee, Jeong-Whan
    • Annual Conference of KIPS
    • /
    • 2015.10a
    • /
    • pp.1822-1825
    • /
    • 2015
  • 본 논문에서는 운동 전후 또는 심장 질환과 관련 있는 사용자가 체중을 측정하면서 동시에 심전도 신호를 측정하여 운동 부하에 따른 심장의 활동 상태를 모니터링 할 수 있는 장치를 고안하였다. 이를 위한 방법으로 체중계에 수정된 바이폴라 금속전극을 적용하여 표준사지 측정법을 이용하여 심장활동 신호를 측정할 수 있는 방법을 제안하였다. 체중계에서 심전도를 측정하기 위해 기존의 Ag-AgCl 전극이 아닌 금속 판 형태의 전극을 사용하였으며 이를 위해 입력 임피던스의 설계를 브릿지 형의 AC-Coupling 회로를 통해 높은 CMRR이 유지되도록 설계하였다. 또한 시시각각 변화하는 노이즈를 제거하기 위해 Savitzky-golay filter를 사용하였으며 이를 통해 Baseline wandering 이 제거된 최종 심장활동 신호를 획득하였다. R-peak 검출을 통해 기준신호와의 심박수 및 Sensitivity의 비교평가를 수행하여 이 장치의 성능을 평가한 결과 심박 검출률의 평균 Sensitivity가 97.1%로 나타났다. 동잡음 제거에 대한 알고리즘이 보다 최적화 되어 최종 출력 신호의 안정성이 향상 된다면 체중계를 통한 심박 검출의 가능성과 그 유효성이 충분할 것으로 사료된다.

Design and Fabrication of Improved Null-Type Torque Magnetometer (개선된 구조의 Null-Type 토크마그네토미터의 설계 및 제작)

  • Kim, Dong-Hyun;Shin, Sung-Chul;Hur, Jeen
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.388-394
    • /
    • 1998
  • We designed and fabricated an improved null-type torque magnetometer for measuring magnetic anisotropy of magnetic materials. This torque magnetometer has a measurement range of $~{\pm}15$ dyne.cm, and the range can be controlled. Resolution is ~0.0005 dyne.cm. Noise level is less than 0.01 dyne.cm with one measurement, and less than 0.004 dyne.cm with 10 averaged measuremets. The precision is less than 0.5 %. In contrast to typical null-type torque magnetometers, we placed a small ferrite magnet in the Helmholtz coil, instead of placing coil in the permanent magnet. From this novel sturucture, we can design a geometrically isotropic and relatively light-weight sample rod. Also, we can prevent the effect of input and output lines of coil exposed in the magnetic field in torque meter. Consequently, our novel null-type torque magnetometer can have a better sensitivity, faster response time, and smaller distortion of torque curve than commercially available torque magnetometers.

  • PDF

The 90° hybrid Coupler having the same output power slope at two output ports (두 개의 출력단자에 동일한 출력 전력 기울기를 갖는 90° hybrid Coupler)

  • Park, Ung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.85-88
    • /
    • 2016
  • Two output ports of $90^{\circ}$ hybrid-coupler are generally the same output power with $90^{\circ}$ phase difference. But, Two output ports of $90^{\circ}$ hybrid-coupler must be the different output slope characteristic about frequency because of the different electrical length. In $90^{\circ}$ hybrid-coupler being the same power distribution, 3-dB power distribution at two output ports only exists near the center frequency. And, the output power difference between two output ports increases in accordance with the further away from the center frequency. This paper proposes $90^{\circ}$ hybrid-coupler being the similar output slope characteristic of two output ports in wideband to modify the ${\lambda}/4$ transmission line of $35-{\Omega}$ characteristic impedance between input port and output port near input port. The power difference between two output ports of the proposed circuit is below 0.2dB over 20% bandwidth of the center frequency in ADS(advanced Design System).

  • PDF

Unequal Multi-Section Power Divider using CPW and Offset Coupled Transmission Lines (CPW와 Offset 결합 전송선로를 이용한 비대칭 다단 분배기)

  • Choi, Jong-Un;Yoon, Young-Chul;Sung, Gyu-Je;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.4
    • /
    • pp.309-315
    • /
    • 2019
  • This paper proposes an implementation of unequal power divider with 1:3 and 1:4 splitting ratio in multi-section structure using CPW and offset coupled transmission line. The power divider consists of a multi-section transmission line and a circuit with parallel capacitors and resistors. A multi-section transmission line was implemented by decomposing a ${\lambda}/4$ single transmission line terminated by an arbitrary impedance and converging it with a multi-section transmission line shorter than $90^{\circ}$ electrical length, and RC parallel circuits were connected between transmission lines to obtain reflection coefficient of output port and isolation characteristics between the output port. In this way, it was confirmed that the transmission lines at the unequal power divider designed at 2 GHz were shorter than ${\lambda}/4$ and implemented at least 27% less than the conventional ones, and that the broadband characteristics could be obtained.

Power Dividers for High Splitting Ratios using Transmission Line Connected with Open and Short Stubs (단선과 단락 스터브가 연결된 전송선로를 이용한 높은 분배비율을 갖는 전력 분배기)

  • Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2021
  • This paper proposes a method of implementing an unequal power divider for high splitting ratios by using transmission lines connected with open and short stubs. The proposed method is an equivalent circuit analysis of a transmission line with an additional port so that it can be converted to an arbitrary impedance in the center of a 2-port transmission line and a 3-port transmission line with an open or short stub connected in parallel to each port. To prove the validity of this method, a Wilkinson power divider with k2 = 20 dB splitting ratio and a Gysel power divider with k2 = 17 dB splitting ratio were designed at a center frequency of 1 GHz using a 3-port transmission line equivalent circuit. The experimental results of the electrical characteristics are in good agreement with the simulation.

Metal Foam Flow Field Effect on PEMFC Performance (금속 폼 유로가 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.442-448
    • /
    • 2021
  • Flow field is an important parameter for polymer electrolyte membrane fuel cell (PEMFC) performance to have an effect on the reactant supply, heat and water diffusion, and contact resistance. In this study, PEMFC performance was investigated using Cu foam flow field at the cathode of 25 cm2 unit cell. Polarization curve and electrochemical impedance spectroscopy were performed at different pressure and relative humidity conditions. The Cu foam showed lower cell performance than that of serpentine type due to its high ohmic resistance, but lower activation and concentration loss due to the even reactant distribution of porous structure. Cu foam has the advantage of effective water transport because of its hydrophobicity. However, it showed low membrane hydration at low humidity condition. The metal foam flow field could improve fuel cell performance with a uniform pressure distribution and effective water management, so future research on the properties of metal foam should be conducted to reduce electrical resistance of bipolar plate.

Energy Conversion Efficiency of TiO2 Dye-sensitized Solar Cells with WO3 Additive (WO3가 첨가된 TiO2 염료감응형 태양전지의 에너지 전환 효율)

  • Lee, Sung Kyu;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-30
    • /
    • 2011
  • In order to improve the energy conversion efficiency of dye-sensitized solar cell (DSSC), the photoelectrode was manufactured by using $TiO_2$ and $WO_3$ on combination effects of two conduction bands. The smash procedure of $TiO_2$ and $WO_3$ was carried out by using a paint shaker to enlarge the contact area of semiconductor with dye and electrolyte. The energy conversion efficiency of prepared DSSC was improved about two times from current-voltage curve based on effects of $WO_3$ and smash. The mechanism was suggested that the conduction band of $WO_3$ worked for prohibiting the trapping effects of electrons in conduction band of $TiO_2$. This result is attributed to the prevention of electron recombination between electron in conduction band of $TiO_2$ with dye and electrolyte. Impedance results indicate the improved electron transport at interface of $TiO_2$/dye/electrolyte.

Effect of Gas Diffusion Layer Compression and Inlet Relative Humidity on PEMFC Performance (기체확산층 압축률과 상대습도가 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.68-74
    • /
    • 2021
  • Gas diffusion layer (GDL) compression is important parameter of polymer electrolyte membrane fuel cell (PEMFC) performance to have an effect on contact resistance, reactants transfer to electrode, water content in membrane and electrode assembly (MEA). In this study, the effect of GDL compression on fuel cell performance was investigated for commercial products, JNT20-A3. Polarization curve and electrochemical impedance spectroscopy was performed at different relative humidity and compression ratio using electrode area of 25 ㎠ unit cell. The contact resistance was reduced to 8, 30 mΩ·㎠ and membrane hydration was increased as GDL compression increase from 18.6% to 38.1% at relative humidity of 100 and 25%, respectively. It was identified through ohmic resistance change at relative humidity conditions that as GDL compression increased, water back-diffusion from cathode and electrolyte membrane hydration was increased because GDL porosity was decreased.