• Title/Summary/Keyword: 전기비저항쌍극자탐사

Search Result 76, Processing Time 0.021 seconds

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Surface geophysical surveys the northern part of the Yongdong basin (Cretaceous), Korea (영동분지(백악기) 북부 지역에 대한 지표물리탐사)

  • Kim, Ji-Su;Han, Soo-Hyung;Rhee, Cheol-U;Kim, Bok-Cheol;Ryang, U-Heon
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.329-336
    • /
    • 2002
  • Electrical resistivity dipole-dipole, seismic refraction, and seismic reflection methods were performed to delineate the boundaries the Yongdong basin(Cretaceous) in terms of physical properties and to ultimately identify the margin architectures of the faults or unconformities. Higer resistivities (approximately >2000 ohm-m) most likely originate from the basement of the basin, contrasting with the lower resistivities from infilled sedimentary rocks. Faults at the eastern margin and unconformities at the western boundary are characterized as high-slope($70^{\circ}$) and gentle-slope($30^{\circ}$) gradients in the resistivity sections, respectively Such features for the boundaries are also suggested by the lower values of seismic velocity and resistivity for the western margin.

  • PDF

Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong (의성 탑리리 오층석탑 기단부 전기비저항 탐사)

  • Oh, Hyundok;Kwon, Moonhee
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.253-260
    • /
    • 2020
  • The five-story stone pagoda in Tamni-ri located in Uiseong County in Gyeongsangbuk-do had an unstable upper structure, and the structural deformation of the foundation stone and the stylobate was severe. In order to repair the base of the pagoda, it must be confirmed if there are support stones inside the base. Resistivity survey was performed to study the inner base stone structure during the repair work. The stylobate was exposed soil and broken stones after removing the walls and the cover of the stylobate. Modified pole-dipole array II was used for the resistivity survey, and compared with the typical pole-dipole array method. And in this study, a physical scale-down model experiment was performed to compare and analyze distortions caused by severe topographical undulations such as right-angled lines. The results show that the stylobate of Five-story Stone Pagoda in Tamni-ri Uiseong has base stones inside the reinforced filling soil and are located beneath the pillar of the body and supporting the pagoda.

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

A Pole-pole Electrical Survey for Groundwater (2극법 전기비저항 탐사에 의한 지하수탐사)

  • Cho Dong-heng;Jee Sang-keun
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.88-93
    • /
    • 2000
  • The present study may be summarized as follows. By means of a pole-pole electrical survey, major geological features, i.e, fresh rocks, fractured & weak & saturated rocks, fresh water bearing aquifer, were successfully delineated in the surveyed area of a granite region in Korea. The subsequent Schlumberger sounding and drilling confirmed the existence of the acquifer at 60 m depth as expected. But one more minor acquifer which does not show up in the resistivity depth section was met at 100 m depth. A simple forward modelling leads the authors to believe that any other electrode configuration, e.g., Wenner, Schlumberger, dipole-dipole, pole-dipole, would not detect the deeper aquifer. Under these circumstances, further studies remain to be done in connection with the spatial resolution in the vertical direction.

  • PDF

Interpretation of Finite HMD Source EM Data using Cagniard Impedance (Cagniard 임피던스를 이용한 수평 자기쌍극자 송신원 전자탐사 자료의 해석)

  • Kwon Hyoung-Seok;Song Yoonho;Seol Soon-Jee;Son Jeong-Sul;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.108-117
    • /
    • 2002
  • We have introduced a new approach to obtain the conductivity information of subsurface using Cagniard impedance over two-dimensional (2-D) model in the presence of horizontal magnetic dipole source with the frequency range of $1\;kHz\~1\;MHz$. Firstly, we designed the method to calculate the apparent resistivity from the ratio between horizontal electric and magnetic fields, Cagniard impedance, considering the source effects when the plane wave assumption is failed in finite source EM problem, and applied it to several numerical models such as homogeneous half-space or layered-earth model. It successfully provided subsurface information even though it is still rough, while the one with plane wave assumption is hard to give useful information. Next, through analyzing Cagniard impedance and apparent resistivity considering source effect over 2-D models containing conductive- or resistive-block, we showed that the possibility of obtaining conductivities of background media and anomaly using this approach. In addition, the apparent resistivity considering source effect and phase pseudosections constructed from Cagniard impedance over the isolated conductive- and resistive block model well demonstrated outlines of anomalies and conductivity distribution even though there were some distortions came from sidelobes caused by 2-D body.

$-{\rho}a$ by One Steel Casing Borehole near Resistivity Survey Line (비저항 측선 근처 철케이싱 시추공 한개에 의한 $-{\rho}a$)

  • Jung, Hyun-Key
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.83-86
    • /
    • 2006
  • From numerical modeling test $-{\rho}a$ by one steel casing borehole near resistivity survey line can be acquired. Negative apparent resistivities even in the flat area are surely subsurface information. Inversion technique for those need to be developed in the near future.

  • PDF

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF