• 제목/요약/키워드: 장비 상태감시

Search Result 95, Processing Time 0.027 seconds

A Design and Implementation of a Remote Status Monitor and Control System for an ADS-B System (ADS-B 시스템 상태 감시 및 원격 제어 시스템의 설계와 구현)

  • Jang, Eunmee;Song, Inseong;Yoon, Wanoh;Choi, Sangbang
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.325-333
    • /
    • 2014
  • An ADS-B system, which is a critical technology in surveillance area of the CNS/ATM, can replace or compensate a conventional radar based surveillance system through the communications among aircrafts. An ADS-B ground system which is to use the ADS-B on the ground air traffic management system consists of various subsystem devices such as ground stations that communicate with the aircrafts, and ADS-B/TIS-B/FIS-B servers. The ADS-B ground system has a form of distributed system and is interconnected through the network. Therefore, a system which can monitor and control the status of the multiple subsystem devices of the ADS-B ground system is essential. In this paper, we designed and implemented a remote status monitor and control system for the ADS-B system that can monitor and control the subsystem devices of the ADS-B system in remote place via SNMP protocol.

진동 모니터링 및 응용

  • 한만철
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.48-51
    • /
    • 1994
  • 일반적으로 모니터링 장비는 주로 플랜트의 운전 상태를 감시하고 제어하는 목적으로 쓰이고 있 는데 계측하는 각종 변수는 변화속도가 빠르지 않은 정적 데이터인 경우가 대부분이라고 할 수 있다. 그러나 기계상태나 구조안전 감시장치 등에 쓰이는 모니터링 장비는 진동 혹은 동적 데이 터를 계측하고 주파수 분석까지를 해야 하기 때문에 데이터의 취득속도가 현저히 빨라야하고 이 에 따른 여러 가지 신호처리 기법을 적용해야 한다. 본고에서는 선박에 쓰이고 있는 기계상태와 구조안전 감시를 위한 모니터링 장비의 동향에 대하여 알아보았다.

  • PDF

The Development of Carrying Equipment to Diagnosis for High Voltage Motors (고압전동기 정지 중 감시를 위한 휴대장비 개발)

  • Choi, Jong-Phil;Song, Wan-Seok;Hyun, Mu-Yong;Choi, Kwang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2025_2026
    • /
    • 2009
  • 본 논문에서는 발전소와 민수 공장에서 많이 사용되는 고압모터를 감시하기 위한 휴대장비 개발에 관하여 언급하였다. 과제에서 개발된 휴대형 감시장비는 정지중인 모터에 전압을 인가하여 권선저항 및 절연저항을 측정하여 모터 권선의 상태를 감시하는 방식으로서 권선 저항 측정모듈과 절연저항 측정모듈의 일체화, 이력관리 기능 등에 초점이 맞추어져 있다.

  • PDF

An Interface System for the Telecommunication Power Monitoring Equipment (통신용 전원감시장치를 위한 인터페이스)

  • Park, Byung-Hun;Kim, Hee-Jun;Youm, Jea-Kyoung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.79-80
    • /
    • 2010
  • 본 논문은 기존 통신용 전원장비를 첨단 통신망에 접속하여 원격제어 및 감시가 가능하게끔 해주는 인터페이스에 관한 연구이다. 인터넷, 휴대폰 등 각종 통신이 발전함에 따라 통신용 전원장비도 날이 갈수록 정밀해지고 고용량화 되어가고 있다. 이와 관련하여 통신장비의 관리 및 유지보수비용 또한 상당한 속도로 증가하고 있는 실정이다. 이러한 시대적 흐름 속에서 비용절감을 위한 연구와 다양한 운영방법들이 논의 되고 있는데 본 논문에서는 통신장비의 관리 및 유지보수 비용의 절감을 위한 원격 감시 제어 환경 속에서 원격지의 전원장비들과 첨단통신망을 연결해주는 인터페이스 장치의 개발에 관하여 논하였다. 개발된 인터페이스 장치는 통신기능을 통하여 전원의 상태를 감시 및 계측할 뿐 아니라 최적온도 및 습도 등의 유지를 위한 제어도 가능한 다기능을 특징으로 한다. 또한 전원의 계측 값들도 485통신을 통하여 바로 디지털 값으로 변환하여 전원감시장치로 보냄으로써 범용성에도 큰 특징을 갖는다고 할 수 있다.

  • PDF

Context-Aware System for Status Monitoring of Industrial Automation Equipment (산업 자동화 장비의 상태감시를 위한 상황인지 시스템)

  • Kim, Kyung-Nam;Jeon, Min-Ho;Kang, Chul-Gyu;Oh, Chang-Heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.552-555
    • /
    • 2010
  • In this paper, we propose a context-aware system using wireless multi sensor module to monitor the state for industrial factory environment. Wireless multi sensor module combines sensing values which are collected from each acceleration, pressure, temperature and gas sensors. Moreover, it delivers this data to server after being encoded by RS code. Thereafter, RS decoder decodes the values that are received from wireless multi sensor module and fixes errors which occur in wireless communication. Based on decoded data, context-aware algorithm sets critical range and compares it to the sensing values, if the sensing values are out of the range, an event occurs by the algorithm. At the same time, if there is another sensing value which is out of the range for standby time T seconds, the algorithm orders 3 steps-alarm to occur depending on each situation. Through this system, it becomes eventually possible to monitor machines' condition effectively. From the simulation, we confirm that this system is efficient to status monitoring of industrial automation equipment.

  • PDF

Design of Context-Aware System for Status Monitoring of Semiconductor Equipment (반도체 장비의 상태감시를 위한 상황인지 시스템 설계)

  • Jeon, Min-Ho;Kang, Chul-Gyu;Jeong, Seung-Heui;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.432-438
    • /
    • 2010
  • In this paper, we propose a system which can perceive status of semiconductor equipment and evaluate its performance. The proposed system acquires the information such acceleration, pressure, temperature and gas sensors in the surrounding semiconductor equipment. After acquiring information, it is sent to server through multi hop transmission. The transmitted data generates 3 steps alarm using context-aware algorithm of unit or multiple event. From the experiment's result of the proposed system, we confirm that the reliability and efficiency of information is more improved about 80% than a system that doesn't use context-aware algorithm. Moreover, this system can be effective status monitoring of semiconductor equipment because lots of client nodes acquire surrounding information.

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

Development of System and Measured Results for Measuring Insulation Resistance of High-Power Cables in Operation (활선 고전력 케이블의 절연저항을 측정하기 위한 시스템 설계 및 측정결과)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.165-170
    • /
    • 2016
  • The XLPE(or CV) cables installed to deliver high electric power from generator at the power station have operating for the last 40 years in Korea. In 6-8 years from the time of initial operation, the cables in operation start a deteriorating process, depending on the installation and usage conditions. Some cables, even before 6-8 years from the installation, can cause accidents due to the faulty construction or other inadequate environments. In order to prevent cable accident in advance, the regular auditing of power cables are required. For a systematic realization of surveillance and prevention of accidents, we have invented a measuring device. In this paper, we present the device installed at Korean Western Power Co. Ltd., in order to detect the deterioration status of insulation resistances of dielectrics in the cables. We present that the measured results by the device we developed show the deteriorating processes in the cables in operation.

Dynamic Layout Design of Spinner MMI for 300mm Wafer (300mm 웨이퍼용 Spinner MMI를 위한 동적 레이아웃 설계)

  • Yoon, Young-Ho;Han, Kwang-Rok;Sohn, Seok-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10a
    • /
    • pp.703-706
    • /
    • 2000
  • 반도체 제조 공정의 효율적인 제어와 감시를 위한 모니터링 시스템을 구성하기 위해서는 장비가 가진 특성과 시스템 환경에서 요구되는 조건들과 동작 상태 둥을 사용자 인터페이스를 통하여 한 눈에 감시할 수 있는 화면 레이아웃이 요구된다. 본 논문에서는 차세대 반도체 장비인 300mm 웨이퍼 가공용 Spinner 의 MMI 개발을 목표로 하여 장비의 구성 요소들의 선택적 접속에 따라서 사용자 인터페이스용 레이아웃을 능동적으로 설계하는 방법에 대하여 기술하였다. 장비를 구성하는 기본 요소들간의 관계를 정의하고, 장비의 사양과 웨이퍼의 가공 목적에 따라 구성 요소들을 자동으로 유연성있게 배치하도록 하였다.

  • PDF

A Study on the Development of the Module for Remote-Controlling Aids to Navigation (항해 안전관련 시설 원격 감시 및 제어모듈의 개발에 관한 연구)

  • Kim, Chang-Je;Song, Jae-Uk;Kim, Chul-Ho
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.269-274
    • /
    • 2002
  • It is said to be very difficult to maintain the aids to navigation such as buoys end lighthouses due to their geographical characteristics. This paper, as a part task of the construction of aids to navigation control center, describes the method to make the module for remote-controlling lighthouses and buoys. We become to be able nor only to get informations such as the condition of lights and batteries, but also to control remotely the aids to navigation by using microwaves so as to maintain them in good condition.