• Title/Summary/Keyword: 잔여레진

Search Result 10, Processing Time 0.033 seconds

A Scanning electron microscopic study of enamel surface by debracketing of ceramic bracket (도재브라켓의 제거방법에 따른 법랑질표면의 주사전자현미경학적 관찰)

  • Park, Mi-Suk;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.613-622
    • /
    • 1996
  • The purposes of this study were to evaluate and compare the frequency of ceramic bracket fracture, frequency of enamel fracture, bond fracture site, adhesive remnant index after mechanical and electrothermal debracketing, to evaluate effectiveness of high and low speed rotary instrument and ultrasonic instrument during residual adhesive remnants removal, and to measure resin film surface(percentage) using by image analyser(Leco 300). Bond fracture site, bracket fracture, and enamel surface damage were examined by scanning electron microscope. The following results were obained : 1. In the mechanical debracketing group, the bond failed predominantly at enamel-adhesive interface with the bulk of adhesive remaining on bracket base. 2. In the eletrothermal debracketing group, the bond failed predominantly at adhesive-bracket interface with the bulk of adhesive remaining on enamel surface. 3. The most effectiveness of residual resin removal was obtained by means of the resin polishing bur and the order of scratch formation was the procedure using tungsten carbide bur, ultrasonic scaler, sof-lex disc, and polishing bur. 4. The order of the resin film surface percentage was ultrasonic scaler, tungsten carbide bur, sof-lex disc, and resin polishing bur.

  • PDF

Shear bond strength of rebonded orthodontic bracket with flowable resin (Flowable resin을 이용한 브라켓의 재접착 시 전단결합강도에 대한 연구)

  • Kim, Dong-Woo;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.207-215
    • /
    • 2005
  • This study was performed to evaluate clinical practicality of the rebonding method with flowable resin without the removal of the residual resin on the debonded theeth and debonded bracket base after debonding. The samples of the control group (group I) were rebonded with Transbond XT using the usual rebonding method after the residual resin was removed. At experimental group, the brackets were rebonded with Transbond XT(group II) and CharmFil Flow (group III) without removal of residual resin which is the possibility becoming the index (or rebonding to similar position With initial bonding. The Shear bond Strength of the each group was measured. Patterns of bonding failure were evaluated with modified ARI score. and the shear bond strength according to patterns of bonding failure at experimental group was compared. Between the control group $(6.51\pm1.21MPa)$ and the group II rebonded with Transbond XT $(6.30\pm1.01MPa)$ did not have significantly difference in the shear bond strength (p=0.534), and the shear bond strength of group II was Significantly lower 4han the group III rebonded With CharmFil Flow $(7.29\pm1.54 MPa)$ (P=0.009). At control group, there was not large difference if distribution of bending failure pattern. But at experimental group, bond failure did not occur in interface between the resin-enamel. and bond failure between the resin-bracket, within the resin was distributed similarly. There was not significantly difference in the shear bond strength according to patterns of bonding failure at experimental group (P>0.05) The result of this study showed that the method suggested in this study aid flowable resin as rebonding adhesive could be useful in clinically.

GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH (강화형 strip crown의 사용)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.132-135
    • /
    • 2005
  • The purpose of this study was to propose the modified strip crown technique for esthetic restoration of primary anterior teeth using glass fibers. Celluloid crown form(3M, USA), Z100(P shade, 3M, USA). Aeliteflo(Bisco Inc., USA), and Clearfil SE Bond(Kuraray Medical Inc., Japan) were used for this technique. Mesh type of glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA) was used for reinforcing material. After trimming the celluloid crown form, resin adhesive and flowable resin were applied on the pre-shaped glass fiber mesh. That mesh was placed on the lingual surface of inside of celluloid crown form and followed by light activation. Composite resin was filled into the celluloid crown form and put it on a prepared tooth and then light activated and finished the margin. The new modified strip crown technique can provide esthetics and increased durability for restoration of primary anterior teeth.

  • PDF

A comparison study of the effects of handpiece speed on teeth in debonding procedure (탈접착 후처치시 핸드피스(handpiece) 속도가 치아에 미치는 영향에 대한 비교 연구)

  • Park, Soo-Byung;Kim, Gu-Ho;Ha, Man-Hee
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.83-91
    • /
    • 2004
  • This study was performed to examine treatment efficiency and patient discomfort rate according to used handpiece speed in clean-up technique. Brackets were bonded to extracted human premolar(50 teeth). After debonding, 50 extracted human premolar were divided Into each two groups(low speed handpiece group with tungsten carbide bur and high speed handpiece group with ultra-fine diamond finishing bur) of 25 according to used handpiece speed in clean-up technique. In clean-up procedure, teeth vibration and pulp thermal changes were measured. After clean-up procedure, the enamel surfaces of randomly selected 10 teeth from each two groups were taken by SEM and evaluated. The findings of this study were as follows ; 1. During resin removal, tooth vibrations of various amplitude in low speed handpiece group were more than those of high speed handpiece. 2. The pulpal thermal changes of high speed handpiece group were significantly higher than those of low speed handpiece group, also the resin removal time in high speed handpiece group was almost as twice as in low speed handpiece group. 3. The figures of SEM to enamel surfaces after resin removal showed that notches and resin remnants in high speed handpiece group were more than those in low speed handpiece group.

Moth-eye 패턴이 형성된 고 투과성 전도성 폴리머 필름 제작

  • Min, Byeong-Hak;Jo, Jung-Yeon;Lee, Seong-Hwan;Han, Gang-Su;Lee, -Heon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.63.1-63.1
    • /
    • 2011
  • 현재 상용 중인 터치패널의 전도성 필름으로는 ITO가 주로 사용된다. 하지만, 디스플레이 기기의 수요 증가와 Indium의 고갈로 인한 ITO의 수요 공급 불균형으로 인한 원가 문제가 대두되고 있다. 이 때문에, Carbon nanotube (CNT), Graphene 등의 대체 투명 전도성 물질들이 연구 중에 있지만 투과율 및 저항 문제 등이 문제가 되고 있다. 본 연구에서는 투명 전도성 필름의 광 투과도 향상을 위하여, 자외선 경화 레진을 이용하여, 전도성 필름 상에 모스 아이 레진 패턴을 형성하는 실험을 진행하였다. 패턴이 형성된 이후에는 Scanning Electro Microscope를 통하여 패턴의 형성 유무를 관찰하였고, UV-vis와 4-point probe를 이용하여 투과도 및 저항을 측정하였다. 실험 결과 모스아이패턴을 필름에 패터닝 함으로써, 전체적으로 투과도가 증가된다는 것을 확인 할 수 있었으며, 투과도의 증가폭은 단면 패터닝보다는 양면 패터닝을 한 경우가 높았다. 그리고 저항 변화에 있어서는 패턴이 있는 부분의 경우 표면 잔여층으로 인하여 급격하게 증가하였지만, 전도면 반대편에 패터닝을 진행한 경우 거의 변화하지 않았다는 것을 확인할 수 있었다. 결과적으로, 본 연구를 통해 나노 임프린트 리소그래피를 통해 전도성 폴리머 필름 상부에 모스아이나노 구조물을 제작하였고, 이를 통해 기존의 전도성 폴리머 필름의 낮은 투과율을 향상시킬 수 있었다.

  • PDF

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

Effects of various CLEAN-UP techniques on enamel surface roughness (수종의 CLEAN-UP technique이 법랑질 표면거칠기에 미치는 영향)

  • CHO, Sang-Wan;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.791-800
    • /
    • 1997
  • Sixty premolars extracted for orthodontic treatment were divided into four groups, and the residual resin was removed with four different rotary finishing instruments at a fixed speed of $18,500{\pm}300 rpm$ on the low speed handpiece. The instruments were G1; No.169L carbide fissure bur, G2: No.2 round bur, G3; No.4 round bur, G4: No.8 round bur. Then, the enamel received a S-second polishing with a rubber cup and a pumice. To find the extent of loss on the enamel at this point, prophylaxis was done with the rubber cup and pumice prior to bonding of the bracket(P1) and removal of residual resin by means of appropriate procedure applicable to each respective group(P2) followed. The final polishing was done with the rubber cup and pumice(P3), and the enamel surface roughness was measured each by the surface measuring instrument. The whole process was observed under a scanning electron microscope to gain the following results: At P2, the enamel surface roughness in G1 showed most smoothly with $2.60{\pm}0.55{\mu}m;\;in\;G2,\;3.24{\pm}0.80{\mu}m;\;in\;G3,\;3.44{\pm}0.94{\mu}m;\;in\;G4,\;3.89{\pm}0.54{\mu}m$, the roughest. G2 and G3 showed no statistical significance(P>0.05). At P3, the enamel surface roughness in G1 showed most smoothly with $2.29{\pm}0.47{\mu}m;\;in\;G2,\;2.44{\pm}0.56{\mu}m;\;in\;G3,\;2.44{\pm}0.56{\mu}m;\;in\;G4,\;2.92{\pm}0.43{\mu}m$, the roughest. G1 vs G2, G3, and G2 vs G3 had no statistical significances(p>0.05). In all groups, P2 and P3 showed rougher in surface roughness than P1, and P2 rougher than P3(p<0.01). In a case of 5-second prophylaxis with the rubber cup and the pumice on a virgin, normal enamel, fine scratches were found under the scanning electron microscope. In all four groups, unremovable gouges remained even after polishing with the ubber and pumice; residual resin was not observed with naked eye when finished with the rubber and pumice, but the resin debris was observed under the scanning electron microscope.

  • PDF

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

A Study on Concentration and Application Time of Lithium Sulfate-Contained Polyacrylic Acid for Adequate Crystal Growth (법랑질 표면에 크리스탈을 형성시키기 위해 사용한 황산리튬이 함유된 폴리아크릴산의 농도와 적용시간에 관한 연구)

  • Roh, Joung-Sub;Kim, Sang-Cheol;Tae, Ki-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.947-954
    • /
    • 1998
  • The purpose of this study was to compare shear bonding strengths and debonding patterns of the ceramic brackets attached on the crystal which were grown on the enamel surface of a tooth with different concentrations of lithium sulphate-contained polyacrylic acid in different application times. Four kinds of concentrations of mixed solutions were made and applied to the enamel surface on extracted human premolars. The solutions were made by adding 0.3M or 0.6M of lithium sulfate to $50\%\;or\;65\%$ of polyacrylic acid with 0.3M sulfuric acid. The solutions were applied for 30 or 60 seconds. After bonding, a universal testing machine was used to measure the shear bond strength, and then observations were made of debonding patterns through the stereoscope. And the enamel surface was observed through the scanning electron microscope to examine the pattern of crystal growth and debonding. The results were as follows: 1. Shear bond strength in the enamel surface treated with $50\%$ polyacrylic acid was higher than that with $65\%$ polyacrylic acid. 2. There were no statistical differences in shear bond strength according to concentration of lithium sulfate and application time of solutions . 3. Enamel surface was almost free of resin debris after debonding. 4. Enamel surface treated with $50\%$ polyacrylic acid showed higher density of crystal growth than that with $65\%$ polyacrylic acid under scanning electron microscope.

  • PDF

Message Delivery and Energy Consumption Analysis on Pocket Switched Network Routing Protocols (Pocket Witched Network 라우팅 프로토콜의 메시지 전송 및 에너지 소비 분석)

  • Cabacas, Regin;Ra, In-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.571-576
    • /
    • 2013
  • Despite the development of the Internet, both in terms of technology and coverage, there are still remote areas and scenarios where connectivity is very difficult to achieve. Pocket Switched Network is a network paradigm that takes the advantage of human mobility to disseminate data. Factors such as mobility of nodes, link failures, discharged batteries, are among the challenges that may compromise connectivity in these networks. This paper presents a performance analysis of existing routing schemes for PSN in terms of delivery probability, overhead ratio, average latency and average residual energy when the number of nodes is increased. We seek to identify a scheme that maximizes data delivery while minimizing communication overhead and thus extending the network lifetime.